Equipment qualification and calibration in FDA Form 483 observations

Showing that equipment and instruments work as intended: installation and operational qualification, calibration and preventive maintenance. FDAgent finds 153 such observations in 115 Form 483s issued to 108 facilities, for inspections that ended between October 2008 and September 2026. Each is quoted below from the 483 FDA posted.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: Form 483 PDFs in FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC. Every quote is from a 483 whose reading passed FDAgent's checks against the scan. FDAgent is independent of FDA.

Observations
153
Each quoted below
Form 483s
115
Posted by FDA
Facilities
108
Distinct FEIs
Most recent
Sep 9, 2026
Inspection end date

Observations by year

These observations by the year the inspection ended. They follow which 483s FDA has posted and FDAgent has read, so they show what is on record, not a trend in FDA's findings. 2026 runs to the latest sync (lighter bar).

Peak: 50 in 2026

Equipment qualification and calibration observations in Form 483s by inspection year
YearObservations
20082
20090
20100
20110
20121
20131
20140
20150
201611
20179
20189
20199
20200
20214
20229
202316
20249
202523
202650

How FDAgent sorts observations into this theme

Two fixed rules, applied by code to every observation FDAgent can quote. An observation counts when either holds. No model and no similarity score decides.

It is tied to one of these 21 CFR entries

21 CFR 211.6321 CFR 211.68(a)21 CFR 211.160(b)(4)21 CFR 820.70(g)21 CFR 820.72

A 483 prints no regulation, so FDAgent ties an observation to a section only when it opens with FDA's own citation wording for that section, word for word.

Or its text contains one of these phrases

“installation qualification” · “operational qualification” · “equipment qualification” · “IQ” · “OQ” · “PQ” · “IOQ” · “calibrat*” · “preventive maintenance” · “preventative maintenance” · “requalif*”

* matches any ending and … up to three words in between. Case is ignored unless a phrase has capitals.

The 153 observations, newest first

Quoted word for word from each Form 483, with only line breaks joined; … marks where the quote is cut. The highlight shows why the observation is in this theme. Each links to FDAgent's page for the 483.

  1. The Pet Apothecary LLCInspection ended Aug 7, 2018 · FEI 3005946041 · Observation 3

    Analytical balances, used for weighing drug materials/components, are not uniquely identified nor appropriately calibrated on a periodic basis, nor periodically weight checked with an appropriate certified weight set. Examples include, but not limited to: - (b) (4) (Model (b) (4) - (b) (4) (Model (b) (4)) - (b) (4) ((b) (4)) - (b) (4) (S/N (b) (4)) No calibration or maintenance records for the aforementioned analytical balances, used for drug …

    Contains “calibrat*”Read the Form 483 →

  2. Auro PharmaciesInspection ended Aug 2, 2018 · FEI 3011893599 · Observation 2

    … On 02/28/2018, your third-party contractor recovered 1 CFU/cubic meter from viable air particle monitoring during routine preventive maintenance of the (b) (4) laminar air flow ISO 5 classified Hood #2. This hood was used to produce "NADTRIHYDRATE 250 MG/VIAL LYOPHILIZED INJECTABLE", lot 180430@16 on 04/30/2018, RX (b) (6). C. Subsequently, on 03/08/2018, your firm recovered 1 CFU/cubic meter from viable air sample from ISO 5 classified Hood #4. …

    Contains “preventive maintenance”Read the Form 483 →

  3. Celltrion Inc.Inspection ended Jul 17, 2018 · FEI 3005241015 · Observation 4

    Procedures describing the calibration of instruments, apparatus, gauges, and recording devices are deficiently written or followed. Specifically, Your firm does not adequately monitor the incubator rooms used to incubate environmental, media fill, and sterility samples. Your most recent temperature mapping study determined hot and cold spots for the incubators; however your routine temperature monitoring gauge is not located in these areas.

    Opens with FDA's citation wording for 21 CFR 211.160(b)(4)Read the Form 483 →

  4. Glenmark Pharmaceuticals Ltd.Inspection ended May 24, 2018 · FEI 3008565058 · Observation 5

    … 3) On 05/21/2018, we observed that your firm has no control over the issuance of qualification protocols and worksheets used for recording of equipment qualification activities. The equipment qualification protocols and worksheets are maintained on both production and QA computers and can be printed without seeking an approval from the QA department as it was evident for Compression ID: EPD264. Your SOP CM/QA028 "Preparation and Approval of …

    Contains “equipment qualification”Read the Form 483 →

  5. Galaxy Surfactants Ltd.Inspection ended Mar 30, 2018 · FEI 3004879807 · Observation 6

    6. Your firm failed to conduct appropriate qualification (DQ, IQ, OQ & PQ) of critical equipment. Specifically, you have not completed the qualification of multiple equipment including but not limited to: [illegible] (which are used in the Stage [illegible] to manufacture [illegible] and [illegible] Step for [illegible] blending step to manufacture [illegible] respectively). These non-qualified equipment were used to manufacture and ship APIs to …

    Contains “IQ”Read the Form 483 →

  6. Plasma Industries Belgium SCRLInspection ended Mar 16, 2018 · FEI 3003208230 · Observation 2

    … The preventative maintenance of the centrifuges, including the centrifuge (b)(4) was not evaluated. iii. The last batch manufactured before the shutdown and the discovery of plasma in the (b)(4) of the centrifuge was not tested to show there was no impact downstream of the centrifugation step; the investigation was closed concluding no impact on product. iv. The investigation failed to address if the process is validated. v. Investigation failed …

    Contains “preventative maintenance”Read the Form 483 →

  7. Plasma Industries Belgium SCRLInspection ended Mar 16, 2018 · FEI 3003208230 · Observation 7

    The preventative maintenance program for the (b)(4) used for CIP for the process and the (b)(4) was not adequately conducted in year 2016 and 2017. The preventative maintenance program did not require a (b)(4) of the (b)(4) (i.e. (b)(4)) at a defined frequency. Specifically, A. The executed preventative maintenance records for the year 2016 and 2017 for the (b)(4) and the (b)(4) does not account for all components and the frequency of maintenance …

    Contains “preventative maintenance”Read the Form 483 →

  8. One Way Drug LLC dba Partell Specialty PharmacyInspection ended Mar 8, 2018 · FEI 3011769075 · Observation 2

    … The incubator is not calibrated to ensure the temperature can maintain (b)(4). The (b)(4) does not contain a visual thermometer to monitor the temperature during BI incubation. c. Your firm conducts (b)(4) sterilization on sealed vials containing pellet products, using an (b)(4). There is no adequate scientific justification for the (b)(4) used to (b)(4) sterilize implantable pellets, including consideration of (b)(4) and the pellets themselves. …

    Contains “calibrat*”Read the Form 483 →

  9. Aurobindo Pharma Ltd.Inspection ended Feb 20, 2018 · FEI 3008461619 · Observation 3

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the qualification of the vial washer and in®® block suite, that are used for washing and sterilizing of § mL vials are not adequate. For example, qualification studies: a) for vial washer failed to demonstrate if vial washer (Eq. Id. # L-PR-QASHM-001) is able to remove …

    Opens with FDA's citation wording for 21 CFR 211.63Read the Form 483 →

  10. Triad Isotopes Inc.Inspection ended Jul 3, 2017 · FEI 3008364285 · Observation 4

    Your firm does not perform any contact sampling on the hood. Your firm has not tested the dose calibrator and peripheral equipment to determine your sanitization is effective.

    Contains “calibrat*”Read the Form 483 →

  11. Torrent Pharmaceuticals LimitedInspection ended Apr 28, 2017 · FEI 3005029956 · Observation 1

    … date 3 June 2016, for the Dissolution Testing of (b) (4) Tablets (b) (4) (b) (4) mg) was updated to include instructions to ensure that the pH meter is calibrated with buffers at pH (b) (4) and (b) (4) immediately before adjusting the pH of the dissolution media. 2. Batch Record Review by Quality Assurance (QA) was deficient: a. The production batch record for (b) (4) Stage (b) (4) Batch (b) (4) had (b) (4) weights recorded for the standard …

    Contains “calibrat*”Read the Form 483 →

  12. Torrent Pharmaceuticals LimitedInspection ended Apr 28, 2017 · FEI 3005029956 · Observation 3

    Laboratory equipment used for analytical testing was used outside of the calibrated range. Specifically, the HPLCs, GCs and dissolution units located in the API, formulation (finished dosage form) and stability sample quality control testing laboratories were used outside of the calibrated range. For example: a. SOP No.: IPQC-124-02, Annexure VIII, titled "Wavelength Accuracy Check" states that wavelength accuracy for HPLCs should be calibrated …

    Contains “calibrat*”Read the Form 483 →

  13. Dr. Reddy's Laboratories Unit 6Inspection ended Apr 4, 2017 · FEI 3002949085 · Observation 1

    Complete records are not always maintained for periodic calibration of laboratory instruments, apparatus, gauges, and recording devices. [For all High Performance Liquid Chromatography systems (HPLC), the firm failed to monitor the lamp hours of their UV detectors. In addition, monitoring of the QC laboratory’s HPLC units does not include a periodic check of the hours of the UV-Vis lamps after 2000 hours of operation as recommended by the …

    Contains “calibrat*”Read the Form 483 →

  14. Meridian Medical Technologies, Inc. a Pfizer CompanyInspection ended Mar 24, 2017 · FEI 1950222 · Observation 10

    … The (b) (4) the products during testing appeared damaged and currently there is no standard operating procedure for conducting preventive maintenance on this equipment. B. We observed that drug product was accumulated on the (b) (4). We observed that the drug product inside the (b) (4) from previous testing can be transferred to the final finished product's (b) (4) after dispensing the drug product and prior to weighing the unit for the delivered …

    Contains “preventive maintenance”Read the Form 483 →

  15. Alkem Laboratories LimitedInspection ended Mar 10, 2017 · FEI 3006370533 · Observation 2

    Master production and control records lack complete manufacturing and control instructions and special notations. A. Procedure QC/082, Operation, Cleaning and Calibration of (b) (4) (Revision 07), does not contain instructions for the use of (b) (4) to complete the validated load pattern in the (b) (4) (G/QC/099). Firm management stated (b) (4) is used to fulfill media loads to be sterilized; however, this is not fully documented. B. Performance …

    Contains “calibrat*”Read the Form 483 →

  16. Cadila Healthcare LimitedInspection ended Mar 1, 2017 · FEI 3005430968 · Observation 1

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, not all manufacturing equipment for use in production of (b) (4) Capsules, USP (b) (4) mg and (b) (4) mg has been qualified. A. The manufacturing area to be used in the commercial production of (b) (4) Capsules, USP (b) (4) mg and (b) (4) mg, referenced in application (b) (4) …

    Opens with FDA's citation wording for 21 CFR 211.63Read the Form 483 →

  17. Dr. Reddy's LaboratoriesInspection ended Feb 21, 2017 · FEI 3005447965 · Observation 2

    Procedures describing the calibration of instruments are deficiently written or followed. Specifically, a) The calibration of the Gas Chromatographic (GC) instruments was incomplete. The review of the ®@ Operational Calibration for the Agilent GC/Headspace (GC/HS) QC-206, conducted by the outside contractor and as in-house calibration, did not include the HS oven temperature, noise and drift, signal to noise and detector accuracy tests as part of …

    Contains “calibrat*”Read the Form 483 →

  18. Park Infusioncare LP dba Preferred HomecareInspection ended Feb 17, 2017 · FEI 3012669716 · Observation 1

    … Furthermore, the pressure gauges between the ISO 7 cleanroom and ISO 7 anteroom areas and the ISO 7 anteroom and unclassified areas had not been calibrated to ensure accurate pressure readings. As such during the months of September, October and November of 2016 pressures in the anteroom appeared negative relative to the cleanroom. During this time, your firm continued aseptic processing of drug products. Your firm purported that there are not …

    Contains “calibrat*”Read the Form 483 →

  19. Sun Pharmaceuticals Industries, Inc.Inspection ended Nov 16, 2016 · FEI 3002807979 · Observation 5

    … in the human machine interface automated compression machine are not periodically reviewed by quality assurance for disassembly, cleaning, change over and preventative maintenance. Quality assurance only reviews the hard copy printout event logs printed by production personnel and attached in the batch production record after the completion of a compression batch that document the activities performed between the start and stop of a production …

    Contains “preventative maintenance”Read the Form 483 →

  20. Sun Pharmaceuticals Industries, Inc.Inspection ended Nov 16, 2016 · FEI 3002807979 · Observation 7

    … Regarding this, Machine equipment qualification performed under Performance Qualification Protocol/Report of Machine Equipment Number MPDGAC03 Protocol No. PQ-MRL 12-00 approved on September 4, 2010 was performed at a set to distance value of @:m. Product development report titled Addendum II to Feasability Trial Report of Tablets mg report FSTR/03/0212-A02, approved on April 18, 2012 was performed at a to 5 distance range value of m to wom. …

    Contains “equipment qualification”Read the Form 483 →

21 CFR sections these observations open with

The sections FDAgent ties the most of these observations to by FDA's wording, with how many of this theme's observations each covers. Each links to its page of FDA citations, warning letters and the regulation text.

Ask FDAgent about equipment qualification and calibration in Form 483s

FDAgent reads FDA's Form 483s, inspections, citations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The observations are the text FDAgent read by OCR from Form 483 PDFs in FDA's Electronic Reading Room, shown only from 483s whose every printed observation passed FDAgent's checks against the scanned text, as on each 483's own page.
  • Which theme an observation belongs to is decided by the fixed rules above; every count on this page is computed from them.
  • A 483 addressed to an individual is listed without the name, and an observation that names a person is left out.
  • FDAgent is independent of FDA.