Galaxy Surfactants Limited
Plot No. N-46/1 &2, Midc, Tarapur, Thane, India
FEI 3004879807
FDA has one inspection on file for Galaxy Surfactants Limited in Thane, India (FEI 3004879807). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit procedures not followed
1. The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, a. The SOP # QC029-01 (Effective date 3/15/2018), Sampling and Testing of Water for Chemical Analysis does not include specifications for ®® water that is used as raw material in the manufacturing of APL®. b. You did not follow your SOP # QC003-00 (Effective date 9/1/2017), Inspection, Sampling, Testing, and Clearance of Finished Goods. You used a non USP and a non-validated method, OCN_USP to release a number of batches of [illegible] including; Lot # BB [illegible]. These batches were released between 2/17/2018 — 3/5/2018. c. You failed to review the process validation report such that your summary report (PVR/OCN-Retro/00) did not include a number of critical parameters including; manufacturing instructions for Stages [illegible] and also for the Stage where you blend several lots (obtained from ®® at Stages), identity of the various equipment used for Stages [illegible] and also for the [illegible] stage of blending, in-process specifications, and the assay data (53 out of [illegible] are missing from the table 18.3 on page 29.
- Observation 2
Stability analytical method not validated
2. Your firm failed to (adequately) validate the analytical method for stability studies of APL®® to support the intended commercialization period and expiry. Specifically, a. GC method, GQM 157 used for the test is neither a USP method nor an internal validated method. b. Your firm is currently using GC method, GQM 157 for the stability testing of APL®® but you have not completed forced degradation studies with this method. c. You have conducted forced degradation study for ®® (Document no. OCN/FDS-1/01-00) and used a non-validated HPLC method as an analytical tool. However, you use a non-validated GC method, GQM 157 as the stability test method at your site N46.
Show observations 3 to 9
- Observation 3
Insufficient stability program for APIs
3. You failed to place on stability at least one batch per year of manufactured APIs and to test at least annually to confirm the stability characteristics of the APIs, appropriate storage conditions and confirm the expiry dates. Specifically, a. In 2016, you did not confirm the stability characteristics and storage conditions for a number of APIs including: [illegible] Lot [illegible]. These APIs were manufactured in 2016 and shipped to US. b. In 2017, your firm only placed on accelerated stability and did not place the products on long term stability studies.
- Observation 4
GMP training program deficiencies
4. Your firm failed to provide GMP training to your employees at the particular operations that the employee performs and GMP as it relates to the employee's functions. Specifically, Only 4 out [illegible] employees (that includes technical staff and the operators as per your Site Master File, SMF-N46-00, Effective date 1/15/2018, page 13) received the GMP training in 2016 and no training was given in 2017. However, SOP # QA011-00 (Effective date 8/12/2017) Training and Evaluation, section 4.1.31 states training frequency should be conducted [illegible]. In addition, you have not provided any refresher training as per section 4.1.33 of the SOP that has a provision for refresher training [illegible].
- Observation 5
Equipment cleaning procedure inadequate
5. Your firm failed to establish an appropriate equipment cleaning procedure to assure an adequate cleaning of equipment and its subsequent release for use in the manufacture of intermediates and APIs. Specifically, Your SOP # PR003-01 (Effective date 2/23/2018) does not specify the maximum time that elapse between the completion of processing and equipment cleaning, when appropriate. In addition, your procedure does not include equipment clean hold time limits prior manufacturing processes.
- Observation 6
Equipment qualification incomplete
6. Your firm failed to conduct appropriate qualification (DQ, IQ, OQ & PQ) of critical equipment. Specifically, you have not completed the qualification of multiple equipment including but not limited to: [illegible] (which are used in the Stage [illegible] to manufacture [illegible] and [illegible] Step for [illegible] blending step to manufacture [illegible] respectively). These non-qualified equipment were used to manufacture and ship APIs to US including; EB Lot # [illegible].
- Observation 7
Unsuitable water used for manufacturing
7. Your firm failed to use water that is suitable for manufacturing of APL®. Specifically, You manufacture water ([illegible] water) at your site from municipality water. The manufactured water quality does not meet (or exceed) the potable water quality such that the pH of water was [illegible] on multiple days including; [illegible]. There were no investigations to correct the water system to meet (or exceed) potable water specification.
- Observation 8
BMRs not conforming to MFR
8. You do not ensure product quality uniformity from batch to batch such that your Batch Manufacturing Records (BMR) does not conform to the Master Formula Record (MFR). You revised your BMR (BMR-[illegible] 001-01, Effective date 11/25/2017) for Crude [illegible] outside the MFR (MFR 001-00, Effective date 8/4/2017) and did not update your MFR. This BMR was used to manufacture an intermediate for multiple APIs that were shipped to US including; [illegible].
- Observation 9
APQR procedure deficiencies
9. Your APQR procedure is deficient such that: a. You manufactured products at your site N46 but you conducted APQR for only one product, [illegible] in 2016-2017. b. The APQR for (APR/N46/01/04) does not contain long term stability data for 2016. c. In your document APR/N46/01/04, you failed to acknowledge a recall and customer complaint. On page 16, you concluded that there were no recall and customer complaints.
Other FEIs recorded as Galaxy Surfactants Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Galaxy Surfactants LimitedFEI 3010166890Tarapur, India
Last inspected 2018-03-23VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004879807 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004879807. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.