Galaxy Surfactants Limited
Plot No. M-3, Midc Boisar, Tarapur, India
FEI 3010166890
FDA has one inspection on file for Galaxy Surfactants Limited in Tarapur, India (FEI 3010166890). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
insufficient GMP training
1. You failed to provide appropriate GMP and position specific training to personnel for the particular operations that each employee performs as it relates to the employee's functions. Specifically a. The operator responsible for the receiving of raw materials was not given access to the SOP that refers to the receipt of raw materials in the warehouse. The respective document, SOP # ST002-00 (Effective date 8/19/2017), Procedure for Receiving of Materials, was not available to the operator in the warehouse. b. Only 9 out of 29 (including technical staff and the operators) employees at the firm received cGMP training in 2017. However, SOP # QA011-00 (Effective date 8/12/2017), Training and Evaluation, section 4.1.31 states [illegible]. In addition, firm also did not provide any refresher training as per section 4.1.33 of the SOP that has a provision for refresher training [illegible].
- Observation 2
unvalidated analytical methods
2. Your firm failed to validate the analytical methods required for the trace analysis of API residue as part of the cleaning validation program. Specifically, there is not validation report that confirms the sensitivity of <USP621> analytical method to detect the established acceptable level of the residue or contaminants. The method's attainable recovery level is also not established.
Show observations 3 to 4
- Observation 3
no stability studies for APIs
3. Your firm failed to place on stability at least one batch of manufactured APIs to monitor the stability characteristics of the API, and to test for appropriate storage conditions and confirm expiry dates. Specifically in 2016 you did not confirm the stability characteristics and storage conditions for a number of APIs including; Lot # [illegible], Lot # [illegible] and Lot # [illegible]. These APIs were manufactured in 2016 and shipped to US.
- Observation 4
deficient annual product review
4. Your annual product review procedure is deficient such that: a. You failed to conduct APR for your product [illegible] for year 2016-17. b. You did not include the stability data for 2016-17 in the APR 2016-17. The 2016-2017 APR [illegible] (Document # QA/M-3/APQI 16-17/00) contain only the observations (not the actual data) with respect to the product specifications (complies with specification) for the APIs that were manufactured in 2011 and 2012. Similarly, the 2016-17 APR for [illegible] (Document # QA/M3/APQR 16-17/00) contains only the observations (not the actual data) with respect to the product specifications (complies with specification) for the API that was manufactured in 2011.
Other FEIs recorded as Galaxy Surfactants Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Galaxy Surfactants LimitedFEI 3004879807Thane, India
Last inspected 2018-03-30VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010166890 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010166890. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.