Galaxy Surfactants Ltd. Form 483, March 2018
FDA issued this Form 483 to Galaxy Surfactants Ltd. in Thane, India (FEI 3004879807) at the end of a drug inspection that ended March 30, 2018. It lists 9 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jun 28, 2018. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 30, 2018
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Jun 28, 2018
- 90 days after the inspection
The 9 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Quality unit procedures not followed
1. The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, a. The SOP # QC029-01 (Effective date 3/15/2018), Sampling and Testing of Water for Chemical Analysis does not include specifications for ®® water that is used as raw material in the manufacturing of APL®. b. You did not follow your SOP # QC003-00 (Effective date 9/1/2017), Inspection, Sampling, Testing, and Clearance of Finished Goods. You used a non USP and a non-validated method, OCN_USP to release a number of batches of [illegible] including; Lot # BB [illegible]. These batches were released between 2/17/2018 — 3/5/2018. c. You failed to review the process validation report such that your summary report (PVR/OCN-Retro/00) did not include a number of critical parameters including; manufacturing instructions for Stages [illegible] and also for the Stage where you blend several lots (obtained from ®® at Stages), identity of the various equipment used for Stages [illegible] and also for the [illegible] stage of blending, in-process specifications, and the assay data (53 out of [illegible] are missing from the table 18.3 on page 29.
- 2
Stability analytical method not validated
2. Your firm failed to (adequately) validate the analytical method for stability studies of APL®® to support the intended commercialization period and expiry. Specifically, a. GC method, GQM 157 used for the test is neither a USP method nor an internal validated method. b. Your firm is currently using GC method, GQM 157 for the stability testing of APL®® but you have not completed forced degradation studies with this method. c. You have conducted forced degradation study for ®® (Document no. OCN/FDS-1/01-00) and used a non-validated HPLC method as an analytical tool. However, you use a non-validated GC method, GQM 157 as the stability test method at your site N46.
- 3
Insufficient stability program for APIs
3. You failed to place on stability at least one batch per year of manufactured APIs and to test at least annually to confirm the stability characteristics of the APIs, appropriate storage conditions and confirm the expiry dates. Specifically, a. In 2016, you did not confirm the stability characteristics and storage conditions for a number of APIs including: [illegible] Lot [illegible]. These APIs were manufactured in 2016 and shipped to US. b. In 2017, your firm only placed on accelerated stability and did not place the products on long term stability studies.
- 4
GMP training program deficiencies
4. Your firm failed to provide GMP training to your employees at the particular operations that the employee performs and GMP as it relates to the employee's functions. Specifically, Only 4 out [illegible] employees (that includes technical staff and the operators as per your Site Master File, SMF-N46-00, Effective date 1/15/2018, page 13) received the GMP training in 2016 and no training was given in 2017. However, SOP # QA011-00 (Effective date 8/12/2017) Training and Evaluation, section 4.1.31 states training frequency should be conducted [illegible]. In addition, you have not provided any refresher training as per section 4.1.33 of the SOP that has a provision for refresher training [illegible].
- 5
Equipment cleaning procedure inadequate
5. Your firm failed to establish an appropriate equipment cleaning procedure to assure an adequate cleaning of equipment and its subsequent release for use in the manufacture of intermediates and APIs. Specifically, Your SOP # PR003-01 (Effective date 2/23/2018) does not specify the maximum time that elapse between the completion of processing and equipment cleaning, when appropriate. In addition, your procedure does not include equipment clean hold time limits prior manufacturing processes.
- 6
Equipment qualification incomplete
6. Your firm failed to conduct appropriate qualification (DQ, IQ, OQ & PQ) of critical equipment. Specifically, you have not completed the qualification of multiple equipment including but not limited to: [illegible] (which are used in the Stage [illegible] to manufacture [illegible] and [illegible] Step for [illegible] blending step to manufacture [illegible] respectively). These non-qualified equipment were used to manufacture and ship APIs to US including; EB Lot # [illegible].
- 7
Unsuitable water used for manufacturing
7. Your firm failed to use water that is suitable for manufacturing of APL®. Specifically, You manufacture water ([illegible] water) at your site from municipality water. The manufactured water quality does not meet (or exceed) the potable water quality such that the pH of water was [illegible] on multiple days including; [illegible]. There were no investigations to correct the water system to meet (or exceed) potable water specification.
- 8
BMRs not conforming to MFR
8. You do not ensure product quality uniformity from batch to batch such that your Batch Manufacturing Records (BMR) does not conform to the Master Formula Record (MFR). You revised your BMR (BMR-[illegible] 001-01, Effective date 11/25/2017) for Crude [illegible] outside the MFR (MFR 001-00, Effective date 8/4/2017) and did not update your MFR. This BMR was used to manufacture an intermediate for multiple APIs that were shipped to US including; [illegible].
- 9
APQR procedure deficiencies
9. Your APQR procedure is deficient such that: a. You manufactured products at your site N46 but you conducted APQR for only one product, [illegible] in 2016-2017. b. The APQR for (APR/N46/01/04) does not contain long term stability data for 2016. c. In your document APR/N46/01/04, you failed to acknowledge a recall and customer complaint. On page 16, you concluded that there were no recall and customer complaints.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.