Prothya Biosolutions Belgium
Avenue De Tyras 109, Brussels, Belgium
FEI 3003208230DUNS 375250156
FDA has one inspection on file for Prothya Biosolutions Belgium in Brussels, Belgium (FEI 3003208230). It ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing and analysis, through Dec 31, 2027. Its registrant is Prothya Biosolutions Belgium (D-U-N-S 375250156).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 1, in 2018
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
CIP validation lacking justification for vessel area
The CIP cleaning validation of Vessel documented under Document (b)(4) entitled "CIP for vessel (b)(4) on (b)(4) did not include a justification for not [illegible] (b)(4) an area of the vessel (vessel (b)(4) that is known to not be (b)(4) by the (b)(4) This vessel is used to contain non-US plasma (not used for as well as The (b)(4) is used to (b)(4) to and (b)(4) the (b)(4) of, centrifuges and used in the manufacturing process for the swelling of the (b)(4)
- Observation 2
Untimely and inadequate deviation investigations
The following deviations (Events) related to (b)(4) were not initiated in a timely manner or are otherwise inadequate: A. Deviation Investigation 79659 initiated 18 August 2016 was opened due to unknown substance (later identified as plasma) found in the (b)(4) and (b)(4) of centrifuges during a shutdown. The investigation is inadequate in the following: i. Lots of the drug substance manufactured prior to the shutdown was not evaluated as part of product impact. ii. The preventative maintenance of the centrifuges, including the centrifuge (b)(4) was not evaluated. iii. The last batch manufactured before the shutdown and the discovery of plasma in the (b)(4) of the centrifuge was not tested to show there was no impact downstream of the centrifugation step; the investigation was closed concluding no impact on product. iv. The investigation failed to address if the process is validated. v. Investigation failed to address the root cause for plasma overflow into the (b)(4) B. Event 104972 which was opened due to the detection of particles during the changing of (b)(4) was opened on 22-Nov-2017 however the date detected was 22-Sep-2017. This deviation was still open during the current inspection. C. Event 105703 which was opened due to the detection of particles on (b)(4) was opened on 05-Dec-2017 however the date detected was 16-Nov-2017. D. Event 105710 which was opened due to the detection of particles on a (b)(4) of (b)(4) was opened on 05-Dec-2017 however the date detected was 16-Nov-2017. E. Event 107670 which was opened due to the detection of particles during the changing of (b)(4) was opened on 11-Jan-2018 however the date detected was 15-Dec-2017. F. Event 109750 which was opened due to the detection of particles on (b)(4) of (b)(4) was opened on 13-Feb-2018 however the date detected was 11-Jan-2018. G. Event 74734 was opened due to the detection of particles while changing (b)(4) The particles found included particles identified as most likely derived from (b)(4) The quality impact assessment states that the particles found are (b)(4) however it does not state that (b)(4) and no specific assessment regarding the presence of these (b)(4) are not normal (b)(4) is documented. H. Event 94220 which was opened due to the detection of particles during the changing of (b)(4) has 2 overdue CAPAs. CAPA 103334 was due 31-Dec-2017 and CAPA 103335 was due 31-Jan-2018. The due dates for these CAPAs have not been extended by the Quality Unit.
Show observations 3 to 8
- Observation 3
CIP procedure lacks deviation initiation requirement
The current procedure for CIP of the (b)(4) fails to require the initiation of a deviation when an atypical event is detected during the (b)(4) of the (b)(4) Specifically, CAPA 81235 was initiated as part of Event Record 79659 to update SOP (b)(4) 1879 version 3.0 to include a clean and (b)(4) clean or a (b)(4) clean. This procedure does not require the operator who performs the (b)(4) or a (b)(4) clean to initiate a deviation when a (b)(4) substance is observed in the (b)(4) of the centrifuge used during the (b)(4) process.
- Observation 4
Change implemented before change control closed
The change to the use of a new (b)(4) for the (b)(4) of the (b)(4) was implemented on February 27, 2018 however the associated change control (Change Control 92345) remained open as of March 15, 2018. As per Document (b)(4) 0527 entitled "Change Control" [illegible] This form was not completed for this change control.
- Observation 5
Particle detection procedure timing issue
As per Document (b)(4) which is allowed to (b)(4) to be initiated for the detection of particles until particle identification is (b)(4)
- Observation 6
No justification for clarifying limits
There is no written justification for the clarifying (b)(4) limits of (b)(4) as stated in Document (b)(4) 2261 - Appendix 1: Production File 2262 / 14.0 entitled (b)(4) which is a portion of the (b)(4) batch record.
- Observation 7
Inadequate preventative maintenance program
The preventative maintenance program for the (b)(4) used for CIP for the process and the (b)(4) was not adequately conducted in year 2016 and 2017. The preventative maintenance program did not require a (b)(4) of the (b)(4) (i.e. (b)(4)) at a defined frequency. Specifically, A. The executed preventative maintenance records for the year 2016 and 2017 for the (b)(4) and the (b)(4) does not account for all components and the frequency of maintenance on each component. B. No corrective and preventative measures were implemented for (b)(4) detected in the (b)(4) detected in 2017. C. On March 12, 2018, during a walk-through of the facility, discoloration was observed (b)(4) The firm explained that the discoloration is due to (b)(4) and that this level of (b)(4) has no product impact.
- Observation 8
Discoloration observed in open operations room
Discoloration resembling (b)(4) was observed on (b)(4) located in the (b)(4) of the Operations Building Room (b)(4) during a walkthrough of the area on 3-12-18. Open operations related the manufacturing of such as the addition of (b)(4) components into (b)(4) used in the (b)(4) and (b)(4) process are performed in this room.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Prothya Biosolutions BelgiumD-U-N-S 375250156
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003208230 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003208230. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.