Skip to content

Glenmark Pharmaceuticals Limited

Plot No 2, Pharma Zone Sez Pithampur; Phase - 2, Dhar, India

FEI 3008565058DUNS 862603186

Company: Glenmark Pharmaceuticals Inc., USA · Linked by exact D-U-N-S match (130597813) in FDA registration data

FDA has 8 inspections on file for Glenmark Pharmaceuticals Limited in Dhar, India (FEI 3008565058), from 2013 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Four of the five FOIA requests for this site have asked FDA for this inspection's records.

5 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Glenmark Pharmaceuticals Inc., USA (D-U-N-S 130597813), has registered 8 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
8, 2013–2025
1 OAI · 3 VAI · 4 NAI
Inspections with 483 observations shown
3 of 8
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
5 requests, latest Jul 24, 2025
Import refusals
5 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Observation 1

      Inadequate cleaning and cross-contamination controls

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, you failed to implement adequate contamination control procedures to ensure drug products manufactured at your site using non-dedicated equipment are not cross-contaminated by residues from the (b><. A. Since (b)(TC, there were approximately [illegible] after cleaning of non-dedicated major production [illegible] detected residue level exceeded the [illegible]; processes are not able to consistently remove [illegible], resulting impacted batches were rejected later on. This equipment (b)(4) (b)ljmug products, including [illegible] shown below. B. Cleaning validation studies [illegible]. (b) Tablets (validation report) [illegible]. LOD: (bH ppm, LOQ: (bfe ppm) are inadequate [illegible]. Minimum acceptable residue can [illegible]; moreover, you [illegible] products manufactured using shared equipment. a. From (bff) No routine monitoring of [illegible] during product change over cleaning and/or [illegible] examples of (bfe) and shipped to the US that are still within expiry. For example (b)l4l the site shipped approximately [illegible] (b)C4l bottles. b. From (bH) to current: you started monitoring of change over cleaning a [illegible] ppm level for Ctiff Tablets. From (bfe) products. C. The firm's VP Quality stated on [illegible] decontamination agent in the facilities used in the processing of [illegible]; confirmed major production equipment used [illegible] decontaminated before it is used to manufacture [illegible]. D. The firm's control procedure CM/PD121, "Entry and Exit Procedure into the Production Facility" allows operators working in processing areas the same day by following gowning and de-gowning procedures. E. The site does not periodically test equipment/facilities to ensure these products do not contain traces about (Cb)l4! F. The firm uses dust collectors (for re-circulated air) in these areas that are not product specific. Instead, the same filter is used for all other (C6)r4 products. The site does not [illegible] residue. You received two consumer complaints on 10/18/2023 and 12/14/2024 respectively in which patients reported an adverse event while using (Cb)l4 tablets related to facilities, equipment, and air supply that is used for (CbTr4 tablets). Your investigations for both complaints were inadequate as you failed to assess potential cross-contamination that may occur when (Cbfl"l drugs are manufactured using shared facilities and equipment.

    2. Observation 2

      Insufficient segregation and area controls

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Separate or defined areas to prevent contamination are deficient re (bf(\.l ,.l.. mg products (CbH Tablets) at your facility. For example: A. You failed to ensure sampling, dispensing, [and] [illegible] for (6) (CbH Tablets) are carried out using dedicated [illegible] systems. For example: • Sampling areas, equipment, and [illegible] mg products are shared with approximately [illegible] Cb><-ous mg product configurations. After sampling and dispensing mg products, you use these areas to sample & dispense (b)(4) mg products without any verification by [illegible] equipment, and air is free from residues (CbTT4l. 2. Areas, major production [illegible] used for other routine (liJ1 a [illegible] of [illegible] mg products; you use these areas for mg products without a verification by appropriate testing that these areas and air is free from residues of other products. 3. c;· packing areas, equipment, and (b)(4) mg products are shared with approximately [illegible] using product configurations. After packing, you use these areas for other [illegible] drug products without any verification that these areas and air are free from residues of (Cb)l4l drug products. B. You don't have cross-contamination prevention and control plan and monitoring of facilities, personnel, equipment and air handling systems to demonstrate routine drug products manufactured at the site using shared facilities and air handling systems are not being contaminated with traces of other products. Your risk assessment (RA/1111/2023/0029) is inadequate as it does not include such controls.

    Show 8 more observations
    1. Observation 3

      Inadequate OOS investigations and reviews

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. Multiple Out of Specification (OOS) and [illegible] specific root causes were identified; however, by statistical evaluation you have attributed failures to the previously validated [illegible] the (CbTT-tl stage. Though the annual stability batch in 2023 (batch# [illegible]) showed OOS results at various stability time points, as part of finding all reserve samples from (CbTT~ of the remaining [illegible]. All [illegible] batches were manufactured using the validated [illegible]. Batches tested you received an additional OOS (OOS/Il 11/2024/0056, Batch# [illegible]) and the batch was recalled. The remaining [illegible] data. Since then, your firm has released [illegible] without re-validating the (CbH~ suspected root cause. B. The root causes assigned to the following arising from dissolution failures were not adequately supported to explain all the data. The specific [illegible] were not documented but an after-failure interview was used to reach a conclusion of analyst error with the use of [illegible] with new samples to obtain passing results. The batches were ultimately released to the US market. - OOS/1104/2024/0045: This investigation was opened on 9/16/2024, when dissolution testing for (t&TT1) Capsules USP (C4~mg) (Batch# [illegible]) gave OOS results during release test. - OOS/1104/2024/0059: This investigation was opened on 11/14/2024, when dissolution testing for (6) Capsules USP (r~mg) (Batch# [illegible]) gave OOS results during release test. - OOS/1104/2024/0060: This investigation was opened on 11/16/2024, when dissolution testing for (Cb1T1) Capsules USP (~ mg) (Batch# [illegible]) gave OOS at 9M stability test. The above three initial OOS results on dissolution test for [illegible] were obtained by three different analysts on different days. The root cause identified as the improper [illegible] and the use of a specific type of [illegible] does not explain how the passing results were obtained with remainder of the capsules in the same sample sets. C. Your firm has recorded 8 OOS investigations for [illegible] in 2024. All of them were for dissolution test and were found to be [illegible]. The causes identified could not be adequately supported as the failure continued until the production was terminated on (bJC), attributed the probable root cause to the [illegible]; however, it would not explain how the product did not have any dissolution issues during the prior three years when approximately [illegible] API source or specification. On 20 Jan 2025 you have added an addendum to your OOS investigations with a new root cause potentially arising [illegible]. D. Approximately 75 instances of extraneous peaks have been recorded during dissolution, assay, content uniformity and impurities tests by HPLC resulting from potential contaminations since 2023. Sources of contaminations have not always been identified or have root causes been adequately supported. The root causes such as 'instrument error' (23 times), 'human error' (6 times), 'other(s)' (42 times) are under investigation.

    2. Observation 4

      Unvalidated analytical test methods

      The accuracy, sensitivity, specificity and reproducibility of analytical methods have not been adequately documented. Specifically, Commercial drug products and Active Pharmaceutical Ingredients (API) test methods, including in-house and compendial test methods were not validated or verified appropriately. More than [illegible] and APIs are routinely released by testing with analytical test methods that have not been adequately validated or verified. The test methods include [illegible] rotation, identification test by IR, UV and TLC. Appropriate parameters like specificity or precision have not been validated or verified. The drug products have [illegible] were distributed to customers in the US and are currently in [illegible], limited to, the following: [illegible].

    3. Observation 5

      Quality unit responsibilities and delays

      The quality control unit lacks responsibility to approve all procedures or specifications impacting on the quality of drug products. Specifically, Since 01 Jan 2023, approximately [illegible] US commercial samples [illegible] completed in a timely manner. These testing delays at [illegible] stations as shown below: This delay is potentially causing several commercial batches to be in the market without having concurrently [illegible] supporting testing. DATES OF INSPECTION (as printed elsewhere on document): 2/03/2025(Mon), 2/04/2025(Tue), 2/05/2025(Wed), 2/06/2025(Thu), 2/07/2025(Fri), 2/10/2025(Mon), 2/11/2025(Tue), 2/12/2025(Wed), 2/13/2025(Thu), 2/14/2025(Fri).

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    6. Mfg / Processing Operations Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.

    7. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve all procedures or specifications impacting on the quality of drug products.

    8. Test methods

      The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unvalidated cleaning test methods

      The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented. Specifically, Your firm's QC laboratory has not validated analytical methods used in the determination of active residue from equipment's used for processing of the following products: HP® Capsules USP? mg &P® mg, 2)? Tablets USP me.§ mg {§ mg &[H me. 3)@@ Tablets, 4)0@ Tablets, 5)0@ Capsules USP™® mg, and 6)P@ Tablets USPP® mg & P97 mg

    2. Observation 2

      Inadequate sampling methodology

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that conform to appropriate standards of identity, strength, quality and purity. Specifically, Your SOP CM/QA034 "Sampling Methodology for [7 is deficient in section 5.5 ¢ sample of ®® |, subsection 5.5.2 indicates "The ®@ sample shall be collected as gram unless and otherwise mentioned in the sampling [ / process validation / batch production record. [+ bags / Glass Bottles with stoppers shall be used for collecting the | samples". For example, There is no mention of the sampling amount collected during unloading of the ®* from @@ locations. IPQA employee responsible for sample collection was unable to explain the sampling amount collected from each location. Additionally, there is no weighting tape indicating the weight of sample collected each time from different locations and the gross weight to make it to gram. - The sampling instructions mentioned in your process validation and batch production records are deficient as there is mention of the glass bottle size and ®® instructions for the samples collected from ®@ locations. SOP CM/QAO034, section 5.5 is used for ®® sampling of the following products: . PW Tablets USP”? mg &®® mg, and . PE Tablets USP“ mg

    Show observations 3 to 5
    1. Observation 3

      Failure to investigate discrepancies

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, e Your firm's QC unit did not investigate in to the issues of API peak seen in the blank injections during method validation for related substances by HPLC method. Additionally, system suitability (precision) standard injections (| ppm) peaks were not integrated A The reintegration of these peaks changed the area of standards by over ™®" ie 30%. o In the past two years, your firm has initiated approximately sixteen (16) Incident reports related to power outages in your QC laboratories which occurred during testing of samples on HPLC and GC equipment. During our review of these incident reports, it was observed that “chromatographers” who processes data and Analytical Quality Assurance (AQA) reviewers who review processed data do not have the user privilege “Verify Incomplete Data in Raw Data Files” in Empower 3. For this reason, during the review of two such incidents during dissolution testing for finished products, the investigation by your firm determined that the interrupted sample injections were processed by chromatographers and showed that the sample did not run. However, during our review of electronic data in the QC laboratory, it was observed that QC managers and the system administrator have the user privilege to “Verify Incomplete Data in Raw Data Files”. Subsequently, we requested your manager to verify the incomplete data and reprocess the injection for both sample sets (two different incidents) and discovered that the injected samples did in fact run, the first incident with approximately ®® minutes out of minutes, and the second with approximately @'| minutes out of’ minutes, with both injections resulting in elution of the principal peak. After reprocessing the incomplete data, your firm performed rate of release calculations on the unreported processed injections, which appeared to be within specification. However, this discrepancy in your firm’s ability to review and investigate all electronic raw data is a significant gap in your Data Integrity procedures and practices reviewed during the current inspection.

    2. Observation 421 CFR 11

      Lack of Part 11 computer controls

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Your firm's manufacturing equipment are not 21 CFR part 11 compliant. For example, A) There are total standalone manufacturing equipment which are not equipped with HMI/PLC/SCADA system. There is no time stamped audit trail, data management, alarm management, archival and retrieval of records on these standalone manufacturing equipment. These equipment includes but are not limited to and that are operated at speed per manufacturing instructions given in BMRs. However, there is no setting as ®@ on these equipment. Your production operator was unable to explain and show the equipment operating speed. This information was not clearly defined at the time of process validation that could significantly impact the quality of products manufactured for the U.S. market. B) Your firm's total % standalone production equipment has an inbuilt HMI system but none of these equipment have time stamped audit trail, data management, alarm management, archival and retrieval of records. These equipment includes but are not limited to C) Your firm's total ®® standalone production equipment has an inbuilt SCADA system but none of these equipment have time stamped audit trail, data management, alarm management, archival and retrieval of records. These equipment have capabilities for printing of audit trail report in real time for only critical process parameters which is complied with the BMRs.

    3. Observation 5

      Quality unit oversight and document control failures

      The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your firm's Quality Unit has no adequate oversight on the raw data pertaining to production and QC laboratory. For example, 1) On 05/15/2018, we observed torn balance printouts, shredded documents, torn draft investigation reports, etc. Your firm's interim investigations pertaining to balance printouts confirmed that production employees dismantled printouts pertaining to balance number EPD292 on 05/10/2018 for the operation of fib tablets ®“ mg, batch number rAd frikid of lot). Your firm's production employees deviated from SOP CQA 061 "Data lifecycle management" section 5.1.2 "Raw Data" and 5.1.3. "Metadata (data about data)" must be contemporaneously and accurately recorded by permanent means. 2) Your firm maintains a total of document destruction bins at various locations throughout the facility and the documents gets shredded using a shredder located in QA documentation cell and shredder area as per SOP CM/QAO050 "Procedure for disposal of GMP documents by shredding". Your SOP CM/QA050 per ANNEXURE-III allows shredding of investigations reports (draft), records of supporting documents to change control, etc. We observed entries for several investigations reports (draft) in your document disposal records that were shredded per SOP CM/QA050. 3) On 05/21/2018, we observed that your firm has no control over the issuance of qualification protocols and worksheets used for recording of equipment qualification activities. The equipment qualification protocols and worksheets are maintained on both production and QA computers and can be printed without seeking an approval from the QA department as it was evident for Compression ID: EPD264. Your SOP CM/QA028 "Preparation and Approval of document" is deficient for the control over issuance and control of qualification documents.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established. Electronic records are used, but they do not meet systems validation, operational system check, employee accountability/responsibility policy, and systems documentation control requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

    2. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Electronic records are used, but they do not meet systems validation, system access limitation, audit trail, operational system check, employee accountability/responsibility policy, systems documentation control, and open systems control requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

    3. Control procedures fail to include the following

      Control procedures fail to include tablet or capsule weight variation and adequacy of mixing to assure uniformity and homogeneity.

  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Jul 24, 2025.

  • Inspection ending Feb 14, 2025OAI

    4 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jul 24, 2025FDA-FOIA-2025-9090Form 483· 1 of 3 sitesClosed
    2. Jun 18, 2025FDA-FOIA-2025-7775Form 483· 1 of 10 sitesWithdrawn
    3. Mar 3, 2025FDA-FOIA-2025-1847Form 483Closed
    4. Feb 19, 2025FDA-FOIA-2025-1558Inspection records· 1 of 2 sitesClosed
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Mar 24, 2025FDA-FOIA-2025-2697Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 8 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3008565058, one row per refused product line.

5 refusals from 2019-01-24 to 2024-11-04 · charged UNAPPROVED on 5 · no FDA sample analysis

FDA firm profile
  • 2024-11-04

    OFLOXACIN (ANTI-BACTERIAL, PART II) (NOT ANTIBIOTIC)61GDY85

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-5875841-6/61/1

  • 2020-08-24

    AMLODIPINE BESYLATE (ANTI-HYPERTENSIVE, PART II)62ODA14

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-7725026-1/21/1

  • 2020-08-24

    TELMISARTAN (ANTI-HYPERTENSIVE - PART II)62ODA09

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsAEK-7725026-1/11/1

  • 2019-01-24

    SEVELAMER HYDROCHLORIDE (PHOSPHATE BINDER)63LDA04

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast Imports113-8490170-5/21/1

  • 2019-01-24

    SEVELAMER HYDROCHLORIDE (PHOSPHATE BINDER)63LDA04

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast Imports113-8490170-5/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Glenmark Pharmaceuticals Inc., USAD-U-N-S 130597813

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Glenmark Pharmaceuticals Inc., USA (D-U-N-S 130597813) as the registrant for this site and the 8 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3008565058 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3008565058. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.