Skip to content

Glenmark Pharmaceuticals Limited

Plot No S - 7, Colvale Industrial Estate, Colvale, India

FEI 3004672766DUNS 677318665

Company: Glenmark Pharmaceuticals Inc., USA · Linked by exact D-U-N-S match (130597813) in FDA registration data

FDA has 7 inspections on file for Glenmark Pharmaceuticals Limited in Colvale, India (FEI 3004672766), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. Two of the four FOIA requests for this site have asked FDA for this inspection's 483.

The most recent OAI inspection ended on May 20, 2022. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.160(b) and 21 CFR 211.192.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Glenmark Pharmaceuticals Inc., USA (D-U-N-S 130597813), has registered 8 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
7, 2009–2026
1 OAI · 5 VAI · 1 NAI
Inspections with 483 observations shown
4 of 7
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
4 requests, latest FY2023
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate equipment cleaning and disinfectant validation

      Equipment and utensils are not cleaned or sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. Specifically, A. Inadequate Cleaning Procedures-Insufficient Time Allocation Your firm's written cleaning procedure, SOP CM/PD002 "Cleaning and Sanitization of Production Areas, Other than Production Areas, Wash Areas and Drain Points", establishes requirements for Type A cleaning and Type B cleaning of (b)(4) manufacturing rooms. Type A cleaning is performed during continued production of the same product, while Type B cleaning is performed during product changeover to prevent cross-contamination between different drug products. Review of cleaning records for (b)(4) rooms revealed documented cleaning times that are physically insufficient to complete all required procedural steps. 1. Type A Cleaning - Examples of Inadequate Times Type A cleaning requires sequential steps for (b)(4) operations. The following examples demonstrate that documented cleaning times do not allow completion of all required steps: March 17, 2026: (b)(4) Room (b)(4) (1 minute) - documented as completing (b)(4). August 18, 2025: (b)(4) Room (b)(4) (5 minutes) - documented as completing (b)(4). March 18, 2026: (b)(4) Room (b)(4) (5 minutes) - documented as completing (b)(4). 2. Type B Cleaning - Examples of Inadequate Times Type B cleaning is performed during product changeover and requires more extensive cleaning than Type A, including wet cleaning (using (b)(4)) and visual inspection of cleaned areas to confirm (b)(4) effectiveness. Review of Type B cleaning records revealed that documented times are insufficient to complete all required steps: April 22, 2026: (b)(4) Facility (Unit (b)(4)), Room (b)(4) (14 minutes) - documented as completing wet cleaning of (b)(4) operations, and visual inspection of floor corners, edges, and under-equipment areas. January 16, 2025: (b)(4) Facility (Unit (b)(4)) Room (b)(4) (8 minutes) - documented as completing wet cleaning of (b)(4) operations, and required visual inspection. February 13, 2025: (b)(4) Facility (Unit (b)(4)) Room (b)(4) (5 minutes) - documented as completing wet cleaning of (b)(4) and required visual inspection. February 21, 2025: (b)(4) (Unit (b)(4)) Room (b)(4) (11 minutes) - documented as completing wet cleaning of (b)(4) operations, and required visual inspection. Your firm has not established a minimum or validated cleaning time for Type A and Type B cubicle cleaning. Without scientifically justified time requirements, there is no basis to determine whether documented cleaning times are adequate to complete all required procedural steps. B. Lack of Validated Contact Time for Disinfectants 1. Protocol MSP/QC/2023/005/00/CMPD002 (effective 13/02/2023) and Summary Report MSR/QC/2023/005/00/CMPD002 (dated 01/06/2024) were conducted to demonstrate the effectiveness of the disinfectants used in the sanitization procedure. However, the study design cannot demonstrate disinfectant efficacy because it lacks the following critical elements: Positive controls, Pre-cleaning microbial counts, Deliberate microbial challenge, Untreated control surfaces, Inadequate Acceptance Criteria. 2. The study's acceptance criteria of "Total aerobic Microbial count: NMT (b)(4) cfu/plate" fails to demonstrate disinfectant efficacy for two reasons: The acceptance criteria is identical to routine environmental monitoring limits for Grade D areas and therefore does not demonstrate disinfectant efficacy. The acceptance criteria measures surface cleanliness, meaning there is no scientific basis to distinguish between effective disinfection and low baseline contamination. There is no scientific justification for the absence of a log reduction calculation requirement. Your firm's own 2016 validation (Protocol VP/MM/QC/206) established acceptance criteria of (b)(4)% reduction for vegetative organisms and ≥(b)(4)% reduction for spores, yet these st

      Shortened here; the PDF has the full text.

    2. Observation 2

      Inadequate controls over computerized manufacturing systems

      Appropriate controls were not exercised over computer or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, A. (b)(4) machines - the (b)(4) are all documented as having no electronic data storage or audit trail capability. These machines are used to manufacture multiple tablet products for distribution in the United States, including (b)(4). As a result: 1. The (b)(4) machines lack electronic data storage and audit trail functionality. While printed reports are generated and subsequently scanned for archival, the original electronic data on the machines themselves cannot be retrieved, trended, or audited. This prevents verification of: a. Authorization status of changes at the time they were made b. Detection of unauthorized modifications to data other than process parameters c. Systematic trending of parameter drift or equipment performance degradation. 2. There is no documented procedure establishing acceptable limits on the number or magnitude of parameter adjustments an operator may make during a single batch run within the validated range. An operator may make unlimited corrections to (b)(4) or other parameters without documented justification, and there is no mechanism to detect whether such frequent adjustments indicate process instability or equipment drift. 3. While non-critical alarms are logged in batch records and a Work Request Memo (WRM) system exists to document equipment issues requiring engineering intervention, there is no documented procedure establishing threshold criteria (frequency or severity triggers) that define when non-critical alarms require investigation and escalation beyond routine maintenance. B. (b)(4) machines - the (b)(4) are used to manufacture multiple tablet products for distribution in the United States, including (b)(4). Although these machines are equipped with electronic data storage and backup capability, appropriate controls are not exercised to assure that changes to process parameters are instituted only by authorized personnel, and procedures do not establish monitoring and investigation requirements for equipment "Non-Critical" alarms and parameter deviations. Specifically: 1. While the electronic audit trail captures date, time, personnel identity, old value, and new value of parameter changes, your procedures do not establish requirements to review the audit trail for: the sequence and frequency of parameter changes during a batch, whether changes were made for documented reasons, whether the pattern of changes indicates process instability or equipment drift, or whether changes were appropriate given the product and process stage. The audit trail is reviewed only for compliance with specification limits, not for assessment of the adequacy or appropriateness of the changes themselves. 2. Your procedures do not establish requirements to monitor the frequency or pattern of non-critical alarms, define investigation criteria or trigger points for repeated non-critical alarms that may indicate emerging equipment problems, or require documentation of non-critical alarm occurrences for trend analysis. 3. While your SOPs establish acceptance limits for process parameters and define alarm thresholds, the procedures do not establish predefined investigation criteria for parameter deviations that do not generate alarms. The SOPs do not establish predefined trigger points for investigation of parameter drift within acceptable limits or trend monitoring of parameters that remain within specification but show directional drift.

    Show observations 3 to 6
    1. Observation 3

      High-risk components not tested per container

      Each component is not tested for conformity with all written specifications for purity, strength, and quality. Specifically, Your firm failed to perform individual container testing, including identity testing with limits for (b)(4) (NMT (b)(4)%), on each individual container of each shipment of each lot of high-risk drug components prior to their use in manufacturing of drug products distributed to the United States market. Your procedure for sample testing, Sampling, Testing and Release of Raw Materials, SOP 19/QC006, allows analysis of (b)(4) samples. The high-risk raw materials tested using (b)(4) samples include: Raw Material Most recent Glenmark material batch # (b)(4). These raw materials have been used to manufacture commercial product intended for the US market including (b)(4).

    2. Observation 4

      Inadequate contamination and cross-contamination controls

      Control systems for the firm's operations are not adequate to prevent contamination or mix-ups. Specifically, A. Differential pressure in the manufacturing areas of the (b)(4) facility (Unit (b)(4)) is not adequately monitored and recorded, and no alarm system is in place to detect differential pressure excursions. A review of the Batch Production Record (BPR) for Batch (b)(4) ((b)(4) USP (b)(4) mcg), confirmed that the differential pressure is recorded only during active batch production, approximately (b)(4), with no continuous monitoring or alarm system to ensure pressure differentials are maintained. Your firm manufactures (b)(4) drug products approved for the U.S. market in Unit (b)(4). Approximately (b)(4) distinct batches - including (b)(4) - were shipped to the U.S. between January 2023 and June 2026. Your firm also manufactures (b)(4) tablets in the same facility as (b)(4) products and these (b)(4) tablets are (b)(4) tablets for at least (b)(4) commercial products marketed in the U.S. All these (b)(4) batches remain within their approved expiry dates as of the date of this inspection (June 30, 2026). B. Although a risk assessment with containment study was done in 2023 and 2025, your firm has not conducted a comprehensive risk assessment prior to this inspection on June 22, 2026, to evaluate the potential for cross-contamination between the (b)(4) manufacturing facility (Unit (b)(4)) and the (b)(4) facility (Unit (b)(4)). The Units are located approximately (b)(4) away from each other. For example, your firm has not performed a scientific evaluation of potential cross-contamination between the (b)(4) two facilities, including an assessment of the location and (b)(4) points of the (b)(4) systems in relation to the (b)(4) facility; the adequacy and a program for periodic environmental monitoring between the facilities; the (b)(4) vents of the (b)(4) facility's (b)(4).

    3. Observation 5

      Annual product reviews omitted complaint records

      Written procedures for annual product reviews are not followed, and the reviews are deficient in that they do not address a review of complaint records for each drug product. Specifically, Your firm failed to include a review of all complaints in the Annual Product Quality Review (APQR). Your procedure, "SOP CM/QA005, Revision 17: Periodic Review of Product Quality of Drug Products," requires the compilation of market complaints for the APQR. However, complaints were not included in the APQR for the following products: A. Product: (b)(4) Tablets The APQR for the review period of March 25, 2024, to March 24, 2025 (APQR/25/US/007) reported zero (0) market complaints. However, a review of your firm's complaint records identified eleven (11) complaints associated with this product within the review period that were not included in the APQR including complaints for lack of efficacy and missing blisters. B. Product: (b)(4) Tablets The APQR for the review period of January 19, 2024, to January 18, 2025 (APQR/25/US/001) reported one (1) market complaint. However, a review of your firm's complaint records identified a total of two (2) complaints associated with this product within the review period. Complaint number MC/I102/2024/0065 for missing blister was not included in the APQR.

    4. Observation 6

      Incomplete lab data due to Empower privileges

      Laboratory records do not include complete data derived from all tests, examinations, and assays necessary to assure compliance with established specifications and standards. Specifically, Your analysts have been granted user privileges within the Empower software that allow them to view numerical results in the review window - including area counts of peaks - while changing processing methods, without requiring the chromatograms to be saved. This configuration allows for the potential previewing of data. While these series of controls were in place, your firm has tested over (b)(4) batches of finished drug products for assay and/or impurities by HPLC since January 2023. These products include, but are not limited to, (b)(4). Furthermore, prior to this inspection, your firm did not conduct a comprehensive risk assessment to identify and control the data integrity risks introduced by these user privilege configurations.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

    3. Prepared for each batch, include complete information

      Batch production and control records do not include complete information relating to the production and control of each batch.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    5. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.

    2. Valid stability test methods

      The written stability program for drug products does not include reliable, meaningful and specific test methods.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    4. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed.

    2. Written Procedures Not Followed

      Written procedures are not followed for the storage of drug product containers and closures.

    3. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Four requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Jun 30, 2026VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Oct 1, 2026FDA-FOIA-2026-9538Form 483Records released
    2. Jul 7, 2026FDA-FOIA-2026-6470Form 483Records released
  • Inspection ending May 20, 2022OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. FY2023FDA-FOIA-2022-8394Form 483Withdrawn
    2. May 23, 2022FDA-FOIA-2022-3786Form 483Withdrawn

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 7 inspections, with how many of them cited each.

Show all 12

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Glenmark Pharmaceuticals Inc., USAD-U-N-S 130597813

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Glenmark Pharmaceuticals Inc., USA (D-U-N-S 130597813) as the registrant for this site and the 8 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3004672766 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3004672766. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.