21 CFR 211.63: Equipment design, size, and location
FDA's inspection data lists 701 Form 483 citations of 21 CFR 211.63 at 586 facilities, from October 2008 to July 31, 2026. 24 warning letters state a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 701
- At 701 inspections
- Facilities cited
- 586
- Distinct FEIs
- Most recent citation
- Jul 31, 2026
- Episciences Inc
- Warning letters
- 24
- State a violation of it
The regulation
The current text of 21 CFR 211.63 from the Electronic Code of Federal Regulations.
§ 211.63 Equipment design, size, and location.
Equipment used in the manufacture, processing, packing, or holding of a drug product shall be of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance.
21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart DRead on eCFR
Citations by year
Form 483 citations of 21 CFR 211.63 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 73 in 2024
| Year | Form 483 citations |
|---|---|
| 2008 | 4 |
| 2009 | 37 |
| 2010 | 37 |
| 2011 | 43 |
| 2012 | 38 |
| 2013 | 32 |
| 2014 | 25 |
| 2015 | 38 |
| 2016 | 28 |
| 2017 | 31 |
| 2018 | 44 |
| 2019 | 51 |
| 2020 | 15 |
| 2021 | 25 |
| 2022 | 45 |
| 2023 | 56 |
| 2024 | 73 |
| 2025 | 60 |
| 2026 | 19 |
How FDA words this citation
FDA's short descriptions and citation text on these 701 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Equipment Design, Size and Location701 citations
Citation text
- “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.”370 citations
- “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.”128 citations
- “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.”49 citations
- “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use and cleaning and maintenance.”36 citations
Show 2 more
- “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use.”30 citations
- “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance.”15 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 211.63, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Biochemical and Scientific Consultants cc2026-07-20 · FEI 3013131635Equipment Design, Size and Location
- Advanced Cosmetic Research Laboratories, Inc.2026-06-26 · FEI 3003059934Equipment Design, Size and Location
Show 4 more
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.63 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 25 observations tie this way. The highlighted sentence is the matched wording.
TAILSTORM HEALTH INC2026-08-28 · Observation 3
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance. Specifically, [illegible] System (b) (4) A. We observed a leaking diaphragm valve after the final (b) (4) step on the (b) (4) skid used to supply (b) (4) for all sterile injectable drugs that contain (b) (4). Examples of drugs that contain (b) (4) from this …
This observation opens with FDA's standard wording for 21 CFR 211.63.
Rubicon Research Limited2026-07-03 · Observation 1
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use. Specifically, (b)(4) used in the [illegible] 122, which is listed as the equipment [illegible] for manufacturing for (b)(4) mg strengths of (b)(4) Tablets, is not qualified. Only an installation qualification has been completed. B) (b)(4) Machine …
This observation opens with FDA's standard wording for 21 CFR 211.63.
Jubilant HollisterStier LLC2026-06-17 · Observation 4
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the quality unit failed to requalify the existing (b)(4) system following the addition of an (b)(4) storage tank and distribution loop in 2011. The (b)(4) system supplies the (b)(4) system, which is used in the manufacture of (b)(4) drug products. A) No Installation …
This observation opens with FDA's standard wording for 21 CFR 211.63.
Show 2 more
Lyophilization Services of New England, Inc.2026-06-10 · Observation 5
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm is unable to use some (b)(4) (b)(4) without breaking first air to open vials. For example, (b)(4) on the (b)(4) (b)(4) which your firm uses for routine interventions during the filling process for sterile drug product (b)(4), cannot be introduced into the (b)(4) …
This observation opens with FDA's standard wording for 21 CFR 211.63.
PQ Pharmacy LLC2026-06-01 · Observation 2
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm has not established adequate procedures and controls for the maintenance, certification, and qualification of HEPA filters, laminar air flow hoods (LAFH), biological safety cabinets (BSC), and cleanroom HVAC systems used for sterile drug production. HVAC failures …
This observation opens with FDA's standard wording for 21 CFR 211.63.
Warning letters stating a violation of 21 CFR 211.63
24 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your firm failed to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance. (21 CFR 211.42(c) and 21 CFR 211.63).”
- USV Private LimitedIssued 2026-11-02
“Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance (21 CFR 211.113(b) and 21 CFR 211.63).”
- Rohto Pharmaceutical Co., Ltd.Issued 2026-10-14
“Your firm failed to perform operations within specifically defined areas of adequate size and to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups in aseptic processing areas. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance (21 CFR 211.42(c)(10) and 21 CFR 211.63).”
- PReye, LLCIssued 2026-08-18
“Your firm failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance (21 CFR 211.63).”
Each letter below states the violation in these words.
- International Medication Systems LimitedIssued 2026-07-02
- Fareva Morton GroveIssued 2026-03-03
- Cosmetic Manufacturers Pty Ltd.Issued 2026-02-06
Often cited at the same inspection
Of the 701 inspections where FDA cited 21 CFR 211.63, the share where it also cited each of these sections.
- 21 CFR 211.22Responsibilities of quality control unit358 (51%)
- 21 CFR 211.67Equipment cleaning and maintenance323 (46%)
- 21 CFR 211.100Written procedures; deviations288 (41%)
- 21 CFR 211.160General requirements286 (41%)
- 21 CFR 211.192Production record review275 (39%)
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures232 (33%)
Ask FDAgent about 21 CFR 211.63
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.