Form 483 citations
701
At 701 inspections
Facilities cited
586
Distinct FEIs
Most recent citation
Jul 31, 2026
Episciences Inc
Warning letters
24
State a violation of it

The regulation

The current text of 21 CFR 211.63 from the Electronic Code of Federal Regulations.

§ 211.63 Equipment design, size, and location.

Equipment used in the manufacture, processing, packing, or holding of a drug product shall be of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance.

21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart DRead on eCFR

Citations by year

Form 483 citations of 21 CFR 211.63 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 73 in 2024

Form 483 citations of 21 CFR 211.63 by inspection year
YearForm 483 citations
20084
200937
201037
201143
201238
201332
201425
201538
201628
201731
201844
201951
202015
202125
202245
202356
202473
202560
202619

How FDA words this citation

FDA's short descriptions and citation text on these 701 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Equipment Design, Size and Location701 citations

Citation text

  • “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.”370 citations
  • “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.”128 citations
  • “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.”49 citations
  • “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use and cleaning and maintenance.”36 citations
Show 2 more
  • “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use.”30 citations
  • “Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance.”15 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 211.63, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Show 4 more

What the observations say

Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.63 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 25 observations tie this way. The highlighted sentence is the matched wording.

  • TAILSTORM HEALTH INC2026-08-28 · Observation 3

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance. Specifically, [illegible] System (b) (4) A. We observed a leaking diaphragm valve after the final (b) (4) step on the (b) (4) skid used to supply (b) (4) for all sterile injectable drugs that contain (b) (4). Examples of drugs that contain (b) (4) from this …

    This observation opens with FDA's standard wording for 21 CFR 211.63.

  • Rubicon Research Limited2026-07-03 · Observation 1

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use. Specifically, (b)(4) used in the [illegible] 122, which is listed as the equipment [illegible] for manufacturing for (b)(4) mg strengths of (b)(4) Tablets, is not qualified. Only an installation qualification has been completed. B) (b)(4) Machine …

    This observation opens with FDA's standard wording for 21 CFR 211.63.

  • Jubilant HollisterStier LLC2026-06-17 · Observation 4

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the quality unit failed to requalify the existing (b)(4) system following the addition of an (b)(4) storage tank and distribution loop in 2011. The (b)(4) system supplies the (b)(4) system, which is used in the manufacture of (b)(4) drug products. A) No Installation …

    This observation opens with FDA's standard wording for 21 CFR 211.63.

Show 2 more
  • Lyophilization Services of New England, Inc.2026-06-10 · Observation 5

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm is unable to use some (b)(4) (b)(4) without breaking first air to open vials. For example, (b)(4) on the (b)(4) (b)(4) which your firm uses for routine interventions during the filling process for sterile drug product (b)(4), cannot be introduced into the (b)(4) …

    This observation opens with FDA's standard wording for 21 CFR 211.63.

  • PQ Pharmacy LLC2026-06-01 · Observation 2

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, your firm has not established adequate procedures and controls for the maintenance, certification, and qualification of HEPA filters, laminar air flow hoods (LAFH), biological safety cabinets (BSC), and cleanroom HVAC systems used for sterile drug production. HVAC failures …

    This observation opens with FDA's standard wording for 21 CFR 211.63.

Warning letters stating a violation of 21 CFR 211.63

24 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.

“Your firm failed to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance. (21 CFR 211.42(c) and 21 CFR 211.63).”
“Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance (21 CFR 211.113(b) and 21 CFR 211.63).”
“Your firm failed to perform operations within specifically defined areas of adequate size and to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups in aseptic processing areas. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance (21 CFR 211.42(c)(10) and 21 CFR 211.63).”
“Your firm failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance (21 CFR 211.63).”

Each letter below states the violation in these words.

Often cited at the same inspection

Of the 701 inspections where FDA cited 21 CFR 211.63, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 211.63

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.63; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.