Jubilant HollisterStier LLC
Washington, USA
FEI 3010477DUNS 069263643
Company: Jubilant HollisterStier LLC · Linked by exact D-U-N-S match (069263643) in FDA registration data
FDA has 19 inspections on file for Jubilant HollisterStier LLC in Washington (FEI 3010477), from 2009 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on May 10, 2013. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Jubilant HollisterStier LLC (D-U-N-S 069263643), has registered 1 other site.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 19, 2009–2026
- 1 OAI · 14 VAI · 3 NAI
- Inspections with 483 observations shown
- 5 of 19
- 1 posted 483 not matched to an inspection
- Requested under FOIA
- 3 requests, latest Aug 21, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
19 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetPosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Incomplete identification testing of raw materials
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, your firm does not always perform complete identification testing of raw materials (b)(4) that is used as an ingredient in the manufacture of your (b)(4) injection and (b)(4) solution (b)(4) products. For (b)(4) raw materials supplied to you by your client used in the manufacture of (b)(4) injection, (b)(4) used in (b)(4), your firm relies solely on the client and raw material supplier's certificates of analysis (CoA) for the analysis of (b)(4) (b)(4) and (b)(4) concentrations. Your firm only performs USP spectroscopic identification testing on (b)(4) raw material supplied to you by your client. The (b)(4) received by your firm from your client, is received in (b)(4) containers. Your firm samples and performs complete identification testing on only (b)(4) lot for each (b)(4) received. At the conclusion of manufacturing finished product (b)(4), your firm tests spent (b)(4) containers used in the manufacture of (b)(4) to confirm the identification of the material used. An analysis for (b)(4) and (b)(4) (b)(4) concentrations is not performed using material from the spent (b)(4) containers used to manufacture (b)(4). Also, these spent containers are not tested prior to manufacturing for identity or (b)(4) and (b)(4) concentrations.
- Observation 2
Expired components not segregated per procedure
Written procedures are not followed for the storage of components. Specifically, Your firm's written procedure (SOP 000497-R2, Disposing of Obsolete/Outdated Warehouse Inventory, Revision: 2, Effective Date: 30 Oct 2023) requires that materials reaching their retest or expiry date be physically segregated. On 06/08/2026 and 06/12/2026, expired components were observed co-mingled with released raw materials, with no physical separation or quarantine designation including, but not limited to: (b)(4) API/USP, Batch: (b)(4), Expiration Date: (b)(4) USP-NF, Batch: (b)(4), Expiration Date: (b)(4) (b)(4) (b)(4), Batch: (b)(4), Expiration Date: (b)(4) (b)(4) Sterile Goggles, Batch: (b)(4), Expiration Date: (b)(4) API/USP, (Batch: (b)(4), EXP: (b)(4)) was used in the manufacturing of (b)(4) (lot #(b)(4)) on (b)(4) and distributed on 03/31/2025. (b)(4) batches of (b)(4) (batch: (b)(4), EXP: (b)(4)) were used in the manufacturing of (b)(4) (i.e., lot #(b)(4)) from (b)(4) (b)(4) batches of (b)(4) (Batch: (b)(4), Expiration Date: (b)(4)) were used in the manufacturing of (b)(4) (i.e., lot #(b)(4)) between (b)(4)
Show observations 3 to 8
- Observation 3
Inadequate investigation of recurring endotoxin failures
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. Specifically, your quality unit failed to adequately investigate fourteen (14) recurring endotoxin out-of-specification (OO) and out-of-trend (OOT) results at (b)(4) system ports (b)(4) and (b)(4) spanning July 2024 through January 2026. These include, but are not limited to the following events: 2024: PR243379, PR248495, and PR252381 2025: PR268501, PR288414, and PR296936 The Quality Unit was unable to identify the source of these recurring failures and implemented CAPAs proved ineffective in preventing recurrence of failures. The source of endotoxin contamination has not been identified. The Quality Unit attributed the failures to biofilm growth and (b)(4) degradation. However, no root cause for the contamination source or the reason for (b)(4) failure has been determined. Furthermore, investigations were not expanded to include adequate monitoring of the (b)(4) system downstream. The (b)(4) system supplies the (b)(4) system, which is used in the manufacture of drug products on Lines (b)(4). The approximate number of commercial drug products by (b)(4) manufacturing line and regulatory center is as follows: Manufacturing Line Regulatory Center Approximate Number of Drug Products (b)(4) (b)(4) CDER Line CBER Line CDER Line Line CBER
- Observation 4
Water system changes without requalification
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. Specifically, the quality unit failed to requalify the existing (b)(4) system following the addition of an (b)(4) storage tank and distribution loop in 2011. The (b)(4) system supplies the (b)(4) system, which is used in the manufacture of (b)(4) drug products. A) No Installation Qualification (IQ), Operational Qualification (OQ), or Performance Qualification (PQ) was conducted for the (b)(4) storage tank ((b)(4)), distribution loop, (b)(4) pump ((b)(4)), or (b)(4) ((b)(4)) B) In Critical Change Request (CCR) 11-177, the firm marked Validation/Revalidation as "Not Required" (NR) without providing justification. C) (b)(4) sampling was redirected to new ports (b)(4) and (b)(4) without re-establishing the validated state of the system at these locations. D) No impact assessment was performed to evaluate the effect of the updated (b)(4) system on the (b)(4) system. E) The quality unit failed to assess the suitability of materials of construction used in the updated (b)(4) system. Specifically, the (b)(4) storage tank (b)(4) is constructed of (b)(4) and the distribution loop piping is constructed of (b)(4). No assessment was performed to determine whether these materials are suitable for use in a system that subsequently supplies (b)(4) (b)(4) system. F) The firm has not established written specifications for (b)(4) and did not evaluate the impact of transitioning between (b)(4) on the (b)(4) system or the (b)(4) system. G) A dead leg was observed in the (b)(4) system.
- Observation 5
Endotoxin test sensitivity and mixing deficient
The sensitivity of test methods have not been established. Specifically, the sensitivity of test methods has not been established. Bacterial endotoxin testing (BET) samples are inadequately mixed, which may produce results that are not representative. On 06/12/2026 a BET of a (b)(4) sample was observed. The (b)(4) sample was collected on 06/11/2026 from port (b)(4) on the (b)(4)-Loop which supports (b)(4) line. During the testing process it was noted that the (b)(4) tubes used to collect the samples were majorly filled with sample volume. Prior to removing sample aliquots for testing, the samples were (b)(4) It was observed that high sample volume did not allow for adequate sample (b)(4) mixing. Products manufactured on line include CDER and CBER regulated drug products.
- Observation 6
No sampling plan for water quality monitoring
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that components conform to appropriate standards of identity, strength, quality and purity. Specifically, the firm does not test or monitor (b)(4) quality at intermediate (b)(4) steps, (b)(4) (b)(4), or (b)(4) storage tank. The quality unit has not established monitoring for incoming feed (b)(4) quality across key chemical attributes, including, but not limited to, (b)(4). No (b)(4) sampling ports or monitoring points are established downstream of (b)(4) equipment, including the (b)(4) unit. This (b)(4) (b)(4) supplies the (b)(4) system, which is used in the manufacture of drug products. (b)(4) The firm's current monitoring of the (b)(4) system and incoming feed (b)(4) is limited to (b)(4) sampling locations, as defined in SOP 015665, titled "EM Sampling: Utility Sampling," Revision 10: (b)(4)
- Observation 7
Lab reprocessing without following procedures
Established test procedures are not followed. Specifically, your firm conducts reprocessing of laboratory analytical samples without following firm procedures, for example: Bacterial Endotoxin Test: A. On 06/15/2026 I reviewed SOP-001186 (b)(4) Method", revision 22, which describes the in-vitro assay for the detection and (b)(4) quantitation of bacterial endotoxin in (b)(4) drugs or solutions for (b)(4) and other biological products. In SOP-001186, in attachment A under section "5. DATA REVIEW", the document describes that after analysis, the laboratory notebook, electronic data, and the audit trail must be reviewed by a secondary analyst. In section 5.1.1, the steps specifically document how to perform the check of the (b)(4) Audit Trail. When reviewing the audit trail associated laboratory event #PR 266255, involving (b)(4) Batch #(b)(4) which, and product, (b)(4) Batch was used to manufacture product, (b)(4) Batch #(b)(4), there was no secondary analyst time stamp indicated in the audit trail. The last time #(b)(4) stamp logged on the audit trail was from the primary analyst who performed the testing and then subsequent data reprocessing. Furthermore, a lead Microbiologist confirmed that if the SOP was followed correctly, the audit trail would stamp a second analyst time stamp. B. SOP-000974 "Data Integrity for Quality Control" serves as a policy document and describes the views and practices of the QC laboratory regarding data integrity. Section 2.3 describes the requirement for reprocessing electronic data. In section 2.3.3, it states specifically that supervisor/manager signature, authorizing the stated changes, must be obtained prior to data reprocessing. While reviewing notebook, NB25018-02 p. 60, which contains the raw data involving (b)(4) testing which was used to manufacture product, (b)(4), Batch #(b)(4), and product, (b)(4) Batch #(b)(4), there was no supervisory signature Batch #(b)(4) documented in the footnote identifying that the data was reprocessed.
- Observation 8
QC data integrity procedures deficient
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, 1) SOP-000974 "Data Integrity for Quality Control, Rev. 3" Attachment 2, provides a general overview only, of your audit trail procedure which governs all audit trail enabled equipment. On 06/17/2026 during discussion with your QC Compliance Scientist of said audit trail protocol for HPLC (b)(4) ((b)(4)) data, it was determined there is no procedure utilized that ensures software specific review is conducted nor that audit trails are conducted in a repeatable manner. SOP-000974 was the only procedure noted as being utilized to conduct said audit trails. Furthermore: A. On 6/16/2026, during discussion of (b)(4) Bacterial Endotoxin Test: (b)(4) Method", one of your lead microbiologists stated that there were two avenues in which the audit trail for the (b)(4) could be accessed. One way, detailed by the procedure, SOP-001186 (b)(4) Bacterial Endotoxin Test: (b)(4) Method", revision 22, which when followed, records a time stamp for accessing the audit trail, with name and date of the user. The analyst explained there was an additional way the audit trail could be accessed, which gave read-only access, and did not provide a time stamp and no trail of date or name of user. The lack of access controls to the audit trail undermines the ability to reconstruct the full course of events related to electronic data review. B. On 6/16/2026, during review of Laboratory Event PR #266255 (b)(4) Batch #(b)(4) Data Reprocessing" which was used to manufacture product, (b)(4) Batch #(b)(4), and product, (b)(4) Batch #(b)(4) audit trail and Laboratory Event PR #289263 "Data Reprocessing for endotoxin testing session: Inadvertently added three negative controls" audit trail, there was no secondary analyst time stamp (no user name nor date), which would document the review of the data reprocessing changes made as indicated in SOP-000974 "Data Integrity for Quality Control", Section 2.3.3. 2) SOP-000974 "Data Integrity for Quality Control, Rev. 3" Attachment 1, section 7.5. "Guidelines for (b)(4) Integration" addresses the use of (b)(4) integration when processing chromatographic data however there is no specificity which outlines practices and review to prevent the manipulation of raw data with (b)(4) integration. 3) There is no policy or procedure which governs the periodic review of your meta-data to ensure the validity and accuracy of your data is maintained over the entire data life cycle. 4) On 06/15/2026, during discussion of your (b)(4) chromatography data, your QC Compliance Scientist stated that there is no procedure which outlines the periodic review of the "message center" in (b)(4) The (b)(4) message center is a centralized troubleshooting and monitoring tool that tracks system events, instrument errors and processing failures. Periodic review of this software feature is critical to ensure the equipment and ultimately data, is true and accurate.
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance18 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Drug product sample
Drug product samples are not representative of the entire batch.
Calculations performed are in the records
Laboratory records do not include a record of all calculations performed in connection with the test.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Lab written procedures
Laboratory written procedures are not followed to ensure that the lab equipment is routinely calibrated.
Sterility/pyrogens - test methods written, followed
Test procedures relative to appropriate laboratory testing for sterility and pyrogens are not written and followed.
Show 13 more citations
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Signatures and dates--person who performs test
Laboratory records do not include the date(s) the tests were performed.
Drug products - samples representative, identified properly
Samples taken of drug products for determination of conformance to written specifications are not representative.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.
Mixing adequacy
The in process control procedures were deficient in that they did not include an examination of the adequacy of mixing to assure uniformity and homogeneity.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Electronic records are used, but they do not meet systems validation, system access limitation, audit trail, and signature to record linking requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, storage, handling, testing, approval, and rejection of components.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
Show 8 more citations
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Written program not followed
The written stability testing program is not followed.
Written in-process control procedures
Written procedures are not established that describe the examinations to be conducted on appropriate samples of in-process materials of each batch.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product.
In-process materials specifications
In-process specifications are not consistent with drug product final specifications and derived from previous acceptable process average and process variability estimates where possible.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Stability sample storage conditions described
The written stability program for drug products does not describe the storage conditions for samples retained for testing.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Documentation of Sampling Performed
The batch production and control records are deficient in that they do not include documentation of sampling performed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Test methods
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Aug 21, 2026. Each one asked for a Form 483.
Inspection ending Jun 17, 2026Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Aug 21, 2026FDA-FOIA-2026-8126Form 483· 1 of 4 sitesRecords released
Inspection ending Jun 6, 2024
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Aug 27, 2024FDA-FOIA-2024-7543Form 483Closed
Inspection ending Aug 31, 2021VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 3, 2023FDA-FOIA-2023-8461Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 17 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 19 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features3 of 4
- 21 CFR 211.113Control of microbiological contamination3 of 4
- 21 CFR 211.22Responsibilities of quality control unit2 of 4
- 21 CFR 211.25Personnel qualifications2 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 4
- 21 CFR 211.160General requirements2 of 4
- 21 CFR 211.165Testing and release for distribution2 of 4
- 21 CFR 211.192Production record review2 of 4
Show all 17
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
- 21 CFR 211.80General requirements1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.166Stability testing1 of 4
- 21 CFR 211.167Special testing requirements1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
- 21 CFR 211.194Laboratory records1 of 4
- 21 CFR 212.60What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?1 of 4
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Jubilant HollisterStier LLCD-U-N-S 069263643
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Jubilant HollisterStier LLC (D-U-N-S 069263643) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Jubilant HollisterStier LLCSpokane, Washington · FEI 3023006244Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3010477 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3010477. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.