Skip to content

21 CFR 211.160: General requirements

FDA's inspection data lists 3,046 Form 483 citations of 21 CFR 211.160 at 1,769 facilities, from October 2008 to September 18, 2026. 88 warning letters state a violation of it.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
3,046
At 2,446 inspections
Facilities cited
1,769
Distinct FEIs
Most recent citation
Sep 18, 2026
Nova Laboratories Limited
Warning letters
88
State a violation of it

The regulation

The current text of 21 CFR 211.160 from the Electronic Code of Federal Regulations.

§ 211.160 General requirements.

(a) The establishment of any specifications, standards, sampling plans, test procedures, or other laboratory control mechanisms required by this subpart, including any change in such specifications, standards, sampling plans, test procedures, or other laboratory control mechanisms, shall be drafted by the appropriate organizational unit and reviewed and approved by the quality control unit. The requirements in this subpart shall be followed and shall be documented at the time of performance. Any deviation from the written specifications, standards, sampling plans, test procedures, or other laboratory control mechanisms shall be recorded and justified.

(b) Laboratory controls shall include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity. Laboratory controls shall include:

(1) Determination of conformity to applicable written specifications for the acceptance of each lot within each shipment of components, drug product containers, closures, and labeling used in the manufacture, processing, packing, or holding of drug products. The specifications shall include a description of the sampling and testing procedures used. Samples shall be representative and adequately identified. Such procedures shall also require appropriate retesting of any component, drug product container, or closure that is subject to deterioration.

(2) Determination of conformance to written specifications and a description of sampling and testing procedures for in-process materials. Such samples shall be representative and properly identified.

(3) Determination of conformance to written descriptions of sampling procedures and appropriate specifications for drug products. Such samples shall be representative and properly identified.

(4) The calibration of instruments, apparatus, gauges, and recording devices at suitable intervals in accordance with an established written program containing specific directions, schedules, limits for accuracy and precision, and provisions for remedial action in the event accuracy and/or precision limits are not met. Instruments, apparatus, gauges, and recording devices not meeting established specifications shall not be used.

21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart IRead on eCFR

Citations by year

Form 483 citations of 21 CFR 211.160 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 243 in 2011

Form 483 citations of 21 CFR 211.160 by inspection year
YearForm 483 citations
200833
2009148
2010211
2011243
2012208
2013157
2014170
2015220
2016222
2017240
2018209
2019210
202040
202195
2022126
2023133
2024134
2025170
202677

How FDA words this citation

FDA's short descriptions and citation text on these 3,046 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Scientifically sound laboratory controls1,452 citations
  • Following/documenting laboratory controls359 citations
  • Calibration - at intervals, written program, remedial action294 citations
  • Lab controls established, including changes218 citations
  • Establishment of calibration procedures143 citations
Show 3 more
  • Deviations from laboratory control requirements134 citations
  • Instruments, apparatus, et. al. not meeting specs63 citations
  • Acceptance of drug products58 citations

Citation text

  • “Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.”288 citations
  • “The calibration of instruments is not done at suitable intervals in accordance with an established written program.”81 citations
  • “Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.”77 citations
  • “Established laboratory control mechanisms are not followed.”71 citations
Show 2 more
  • “Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.”57 citations
  • “Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.”55 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 211.160, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Show 4 more

What the observations say

Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.160 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 81 observations tie this way. The highlighted sentence is the matched wording.

  • Hikma Pharmaceuticals USA Inc.2024-06-12 · Observation 2

    Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, your firm's co-validated method transfer, Report CHH15181 Method Transfer Report for SOP CHH15817 (TMD227) Determination of Fentanyl in Fentanyl Citrate in 0.9% Sodium Chloride Injection IV Bags omits established …

    This observation opens with FDA's standard wording for 21 CFR 211.160(b).FDA also lists this citation for this inspection.

  • LeeSar Inc2026-09-23 · Observation 5

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, A. Your firm established a pH specification of (b)(4) as of 08/19/2022 for finished compounded drug product Azithromycin 500mg in a 250mL Dextrose 5% IV Bag but expanded the specification to (b)(4) on 12/03/2025 …

    This observation opens with FDA's standard wording for 21 CFR 211.160(b).

  • RC Outsourcing LLC2026-09-03 · Observation 6

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm continues to fail to provide a scientific rationale to support the established method and limits for subvisible particle testing of Avastin (bevacizumab) 1.75 mg/0.07 mL for intravitreal injection. Your …

    This observation opens with FDA's standard wording for 21 CFR 211.160(b).

Show 2 more
  • TAILSTORM HEALTH INC2026-08-28 · Observation 5

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Growth Media A. QC microbiology personnel use Standard Methods (b) (4) (Plate Count (b) (4)) for all (b) (4) bioburden samples. There is inadequate …

    This observation opens with FDA's standard wording for 21 CFR 211.160(b).

  • STAQ Pharma of Ohio LLC2026-08-19 · Observation 1

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm's visual inspection qualification procedure for sterile injectable drug products compounded and packaged in syringes is inadequate to ensure that visual …

    This observation opens with FDA's standard wording for 21 CFR 211.160(b).

Warning letters stating a violation of 21 CFR 211.160

88 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.

“Your firm failed to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity (21 CFR 211.160(b)).”

Each letter below states the violation in these words.

“Failure to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality, and purity, as required by 21 CFR 211.160(b).”

Often cited at the same inspection

Of the 2,446 inspections where FDA cited 21 CFR 211.160, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 211.160

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

Topics that count this section:Laboratory controls

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.160; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.