TAILSTORM HEALTH INC
Arizona
FEI 3015929581DUNS 167439715
Company: MEDIVANT HEALTHCARE · Linked by exact D-U-N-S match (167439715) in FDA registration data
FDA has 3 inspections on file for TAILSTORM HEALTH INC in Arizona (FEI 3015929581), from 2021 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.
The most recent OAI inspection ended on May 23, 2025. No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing and repacking, through Dec 31, 2027. Its registrant is TAILSTORM HEALTH INC DBA MEDIVANT HEALTHCARE (D-U-N-S 167439715).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 3, 2021–2026
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 3
- 1 PDF not read yet
- Requested under FOIA
- 2 requests, latest Jul 29, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Aseptic areas deficient for sterile processing
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, (b) (4) operational/dynamic certification of the (b) (4) Vial Filling, Stoppering and Sealing Machine, ISO 5 (b) (4) Filling Line cleanroom suite does not represent routine production operations. For example, ISO 5 Filling Line was not fully assembled or in-operation, and there was one cleanroom technician outside the (b) (4) during dynamic nonviable particulate (NVP) monitoring. We observed up to (b) (4) technicians inside the ISO 7 buffer room for the ISO 5 (b) (4) during filling of Lidocaine 2% Injection, 10 mL vial, batch 2608002. Records reviewed included: Project AZ-MVDT261801C-1, (b) (4) Cleanroom Testing and Certification, dated April 2026; and Project AZ-MVDT251301C-1, Cleanroom Suite Certification, dated October 2025. All sterile drugs are manufactured on ISO 5 Filling Line. The personnel, line setup, and production operations inside the ISO 5 (b) (4) are the same for aseptically filled and (b) (4) sterilized drugs. Examples of aseptically filled drugs include Lorazepam Injection USP, 2 mg/mL, lot 2510002; and Lorazepam Injection USP, 2 mg/mL, lot 2511001.
- Observation 2
Sterile contamination prevention procedures inadequate
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, Autoclave Qualification and routine monitoring of the (b) (4) equipment ID #PE001, is deficient. A. There is inadequate written justification to place (b) (4) in the (b) (4) of the (b) (4) as the only process verification for routine sterilization loads. The rationale for the location of the within the (b) (4) is inadequate. B. Operators do not use Biological Indicators (BIs) (b) (4) sterilization (b) (4). The approved procedures only require BIs during (b) (4) qualification of (b) (4) loads. The most recent (b) (4) qualification is documented in (b) (4).PQ.0004, Performance Qualification-(b) (4) Report, (b) (4) PE001, report approved 06/19/26. C. Your procedures only require a (b) (4) air removal test during (b) (4) qualification of the (b) (4). Technicians do not perform (b) (4) tests before any routine (b) (4) cycles. There is inadequate written justification for the frequency of air removal tests. Technicians use (b) (4) PE001 to (b) (4) sterilize finished drug products and sterilize reusable product-contact parts, (b) (4) tubing, (b) (4), utensils, and other items used during production of all commercial sterile drugs on ISO 5 Filling Line. Examples of drugs manufactured with product-contact equipment sterilized in PE001 and then (b) (4) sterilized in PE001 include: Ketamine 10% USP, 100 mg/mL, 5 mL, SDV, lot 2602003; Lidocaine HCl 1%/Epinephrine Bitartrate 10 mcg/mL Injection USP, 10 mL, SDV, lot 2603001; Albuterol Sulfate 0.5%, 10 mL, lot 2512002; and Bupivacaine Hydrochloride 0.5%/Epinephrine Bitartrate 5 mcg/mL Injection, 10 mL vial, lot 2608001. Media Fill D. Operators do not verify the [illegible] of prepared (b) (4) culture medium used in aseptic process simulation media fills on ISO 5 Filling Line. There is inadequate assurance that the (b) (4) is suitable to validate the aseptic filling process for Lorazepam Injection. We reviewed the batch record for Media Fill, batch CHMF/26/001, completed (b) (4), approved 06/11/26. E. Technicians do not use BIs for routine or periodic monitoring of the (b) (4) cycle used for (b) (4) of ISO 5 Filling Line and the ISO 7 buffer room before filling. F. The (b) (4) surface remains folded inside the open (b) (4) pouch during the (b) (4) cycle for ISO 5 Filling Line and the ISO 7 buffer room. There are no BIs or (b) (4) placed inside the partially open pouches to demonstrate the (b) (4) adequately (b) (4) the (b) (4) that are exposed to the environment during installation of the (b) (4) in (b) (4). Personnel Monitoring G. Personnel monitoring specifications for (b) (4) hands, forearms, chest, and forehead are not scientifically justified. Your firm uses the ISO 7 microbial monitoring limits ((b) (4) CFU/plate alert and CFU/plate action) to evaluate samples from operators that use (b) (4) to perform closed-door interventions in the ISO 5 Filling Line. Samples collected from operators after open-door interventions are the only personnel samples held to the ISO 5 microbial limits ((b) (4) CFU/plate).
Show observations 3 to 5
- Observation 3
Equipment design unsuitable for intended use
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance. Specifically, [illegible] System (b) (4) A. We observed a leaking diaphragm valve after the final (b) (4) step on the (b) (4) skid used to supply (b) (4) for all sterile injectable drugs that contain (b) (4). Examples of drugs that contain (b) (4) from this system include: Ketamine 10% USP, 100 mg/mL, 5 mL, SDV, lot 2602003; Lidocaine HCl 1%/Epinephrine Bitartrate 10 mcg/mL Injection USP, 10 mL, SDV, lot 2603001; Albuterol Sulfate 0.5%, 10 mL, lot 2512002; Bupivacaine Hydrochloride 0.5%/Epinephrine Bitartrate 5 mcg/mL Injection, 10 mL vial, lot 2608001. B. There is an approximately one-foot-long (b) (4) connected to the (b) (4) for the (b) (4) on the (b) (4) System. [illegible] We observed numerous deficiencies with the design, use, testing, and maintenance of the ambient temperature, (b) (4) construction (b) (4) System dedicated to supply (b) (4) to the [illegible] equipment ID #PE001, inside the [illegible] Line Cleanroom suite. Operators use (b) (4) [illegible] reusable product-contact parts and (b) (4) sterilize injectable drugs on ISO 5 Filling Line. C. The (b) (4) System is not sampled or tested for conformance with any written specifications for chemical, microbiological, or physical attributes. D. [illegible] step which was the beginning of the distribution line is closed. (b) (4) remains stagnant in the (b) (4) System, ambient temperature (b) (4) distribution line, flexible hose connection to the (b) (4) and (b) (4) tank inside the (b) (4) for more than (b) (4) when there is no production scheduled. There was no written justification for the start-up procedure for the (b) (4) System or (b) (4) PE001. The (b) (4) System includes numerous insanitary threaded connections, hose clamp connections, and (b) (4). This includes E. [illegible] hose clamp connections after the final (b) (4) step. F. [illegible] G. [illegible] H. [illegible] I. [illegible] J. [illegible] sterilize the individually wrapped (b) (4) and then install them on the (b) (4) before the (b) (4) cycle for each (b) (4) sterilized or aseptically filled batch. K. There is no validation data to support unlimited (b) (4) sterilization cycles of (b) (4) before replacement. (b) (4) are not individually identified. The number of uses and sterilization cycles are not tracked. Examples of drugs manufactured with product-contact equipment sterilized in [illegible] PE001 [illegible] include: Ketamine 10% USP, 100 mg/mL, 5 mL, SDV, lot 2602003; Lidocaine HCl 1%/Epinephrine Bitartrate 10 mcg/mL Injection USP, 10 mL, SDV, lot 2603001; Albuterol Sulfate 0.5%, 10 mL, lot 2512002; and Bupivacaine Hydrochloride 0.5%/Epinephrine Bitartrate 5 mcg/mL Injection, 10 mL vial, lot 2608001.
- Observation 4
Investigations into discrepancies not documented
Written records are not always made of investigations into unexplained discrepancies. Specifically, Particulate Matter A. Production processes, procedures, and equipment do not adequately exclude particulates and other potential contaminants from sterile injectable and oral inhalation drug product vials. I reviewed the two most recent (b) (4) reports for Trending of Visible Particle at Visual Inspection. The trend reports include results from 100% visual inspection and AQL inspection of finished sterile drug vials. a. PROT.GSP.0025, Visible Particle Trending August-Dec 2025, approved 02/03/26, documents personnel found visible particulates in multiple vials from all batches manufactured and inspected during the review period. The number of vials rejected for particulate matter ranged from (b) (4) (0.03%) to (b) (4) (0.46%) vials in batches that were released. b. PROT.GSP.0035, Visible Particle Trending January 2026-June 2026, approved 08/18/26, documents personnel found visible particulates in at least one vial from all batches manufactured and inspected during the review period. The number of vials rejected for particulate matter ranged from (b) (4) (<0.01%) to (b) (4) (0.16%) vials. B. There is no written investigation of how extrinsic controlled particulates such as non-shedding cleanroom wipes, cleanroom (b) (4), and goggles material routinely enter vials during filling. C. There is inadequate scientific justification for the (b) (4) Reject Acceptance Rate Limit for critical defects per batch. Balances D. Dispensing room Balance PE026 was found out-of-tolerance at the (b) (4) and (b) (4) weights during the 10/08/25 calibration. Balance PE026 was found out-of-tolerance at the (b) (4) weight during the 04/15/25 calibration. There was no investigation documented. E. Dispensing room Balance PE027 was found out-of-tolerance at the (b) (4) and (b) (4) weights during the 10/08/25 calibration. Balance PE027 was found out-of-tolerance at the (b) (4) and (b) (4) weights during the 04/15/25 calibration. There was no investigation documented. Warehousing F. The (b) (4) Environmental Monitoring Trend Report for the Raw Material (b) (4) storage area (May 1-31, 2026) documents the temperature readings from sensors (b) (4) and (b) (4) exceeded the High Warning Limit of (b) (4) on multiple occasions throughout the month of May 2026. Maximum temperature readings on both sensors approached or reached the High Alarm Limit of (b) (4) during the same period. Quality management stated they notified the engineering department but did not document the excursion or initiate an investigation. Your firm does not have an SOP that addresses maintaining adequate storage conditions, and temperature controls, for raw materials and finished goods stored in the warehouse with instructions on documenting and investigating high warning or high alarm temperature limits excursions.
- Observation 5
Laboratory controls lack appropriate specifications
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Growth Media A. QC microbiology personnel use Standard Methods (b) (4) (Plate Count (b) (4)) for all (b) (4) bioburden samples. There is inadequate justification to use this high (b) (4) (b) (4) instead of (b) (4) designed to recover microorganisms from low (b) (4) (b) (4) systems. Growth promotion on the manufacturer COA for Plate Count (b) (4) only lists Staphylococcus aureus, Escherichia coli, and Enterococcus faecalis. It does not include waterborne pathogenic microorganisms of interest such as B. cepacia or P. aeruginosa that are known to colonize high purity (b) (4) systems. B. The firm accepts Plate Count (b) (4) plates based on manufacturer COA and does not perform growth promotion before use. Nitrogen Your firm uses nitrogen for pre-gassing vials and blanketing drug product solution in all lots of Lidocaine/Epinephrine Injection, Bupivacaine/Epinephrine Injection, and Lorazepam Injection. We observed multiple apparent deficiencies related to nitrogen. C. There was inadequate written justification to confirm that (b) (4) testing of nitrogen generated in-house ensured the nitrogen met all applicable standards each time it was used as a product-contact gas in sterile injectable and oral inhalation drugs. Drugs that require a nitrogen overlay include all lots of Lidocaine/Epinephrine Injection, Bupivacaine/Epinephrine Injection, and Lorazepam Injection. Examples of drugs manufactured with nitrogen generated in-house are Lidocaine HCl 1%/Epinephrine Bitartrate 10 mcg/mL Injection USP, 10 mL, SDV, lot 2603001; and Lorazepam Injection USP, 2 mg/mL, lot 2510002. D. Manufacturing personnel do not (b) (4) test the (b) (4) attached to ISO 5 Filling Line. There is no scientific justification for the (b) (4) replacement interval for this point-of-use nitrogen (b) (4). E. The firm did not conduct ID tests or any other analyses on Ultra High Purity (UHP) Nitrogen, lot (b) (4) accepted based on supplier COA. This is a product-contact gas used during production of Bupivacaine Hydrochloride 0.5%/Epinephrine Bitartrate 5 mcg/mL Injection, 10 mL vials, lot 2608001. F. Operators confirmed the (b) (4) of the (b) (4) they attach to the connection point for UHP Nitrogen cylinders in February 2026. Engineering technicians remove the (b) (4) when not in-use and install it when requested by production personnel. Technicians used the (b) (4) in August 2026 without performing a (b) (4) test. There is no written justification for the (b) (4) test interval. Operators (b) (4) gas from UHP Nitrogen cylinder, lot (b) (4) (b) (4), during production of Bupivacaine Hydrochloride 0.5%/Epinephrine Bitartrate 5 mcg/mL Injection, 10 mL vials, lot 2608001. Ethylene Glycol and Diethylene Glycol Testing G. Your firm did not perform all specific identity tests for Propylene Glycol, lot (b) (4) and Polyethylene Glycol 400, lot (b) (4) [illegible] for Diethylene Glycol and Ethylene Glycol [illegible] high-risk drug components. These high-risk components were used in the manufacturing of Lorazepam Injection USP, 2 mg/mL, lot 2510001 (first distribution 12/02/25), lot 2510002 (first distribution 12/01/25), and 2511001 (first distribution 05/11/26). Also, your SOP titled (b) (4).LAB.0025 - Sample Pooling Strategy for Diethylene Glycol and Ethylene Glycol (DEG/EG), effective 21 Oct 2025, instructs personnel to pool [illegible] for testing of [illegible] drug [illegible] used in manufacturing [illegible].
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
Equipment for Environmental Control
Equipment for adequate control over micro-organisms is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
- FDCA 503B(a)(10)
Container label, outsourcer facility
The container labels of your outsourcing facility's drug products are deficient.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 29, 2025. Each one asked for a Form 483.
Inspection ending May 23, 2025OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 29, 2025FDA-FOIA-2025-9184Form 483· 1 of 5 sitesClosed
Inspection ending Jul 21, 2021VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jan 27, 2025FDA-FOIA-2025-731Form 483Withdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 3 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- TAILSTORM HEALTH INC DBA MEDIVANT HEALTHCARED-U-N-S 167439715
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as TAILSTORM HEALTH INC
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
TAILSTORM HEALTH INCFEI 3022483154Phoenix, AZ, United States
Last inspected 2025-11-14
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015929581 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015929581. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.