21 CFR 211.46: Ventilation, air filtration, air heating and cooling
FDA's inspection data lists 226 Form 483 citations of 21 CFR 211.46 at 206 facilities, from November 2008 to August 21, 2026. 1 warning letter states a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 226
- At 218 inspections
- Facilities cited
- 206
- Distinct FEIs
- Most recent citation
- Aug 21, 2026
- Natco Pharma Limited
- Warning letters
- 1
- State a violation of it
The regulation
The current text of 21 CFR 211.46 from the Electronic Code of Federal Regulations.
§ 211.46 Ventilation, air filtration, air heating and cooling.
(a) Adequate ventilation shall be provided.
(b) Equipment for adequate control over air pressure, micro-organisms, dust, humidity, and temperature shall be provided when appropriate for the manufacture, processing, packing, or holding of a drug product.
(c) Air filtration systems, including prefilters and particulate matter air filters, shall be used when appropriate on air supplies to production areas. If air is recirculated to production areas, measures shall be taken to control recirculation of dust from production. In areas where air contamination occurs during production, there shall be adequate exhaust systems or other systems adequate to control contaminants.
(d) Air-handling systems for the manufacture, processing, and packing of penicillin shall be completely separate from those for other drug products for human use.
21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart CRead on eCFR
Citations by year
Form 483 citations of 21 CFR 211.46 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 21 in 2010
| Year | Form 483 citations |
|---|---|
| 2008 | 4 |
| 2009 | 18 |
| 2010 | 21 |
| 2011 | 14 |
| 2012 | 10 |
| 2013 | 15 |
| 2014 | 16 |
| 2015 | 16 |
| 2016 | 8 |
| 2017 | 21 |
| 2018 | 11 |
| 2019 | 16 |
| 2020 | 5 |
| 2021 | 8 |
| 2022 | 10 |
| 2023 | 8 |
| 2024 | 7 |
| 2025 | 11 |
| 2026 | 7 |
How FDA words this citation
FDA's short descriptions and citation text on these 226 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Equipment for Environmental Control167 citations
- Air filtration system lacking in production area21 citations
- Exhaust systems inadequate to control air contamination21 citations
- Penicillin air handling systems not kept separate7 citations
- Adequate ventilation not provided6 citations
Show 1 more
- Air recirculation of dust from production areas4 citations
Citation text
- “Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.”40 citations
- “Equipment for adequate control over temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.”33 citations
- “Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.”23 citations
- “Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination occurs during production.”21 citations
Show 2 more
- “The production area air supply lacks an appropriate air filtration system.”21 citations
- “Equipment for adequate control over micro-organisms is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.”14 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 211.46, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Element Materials Technology Boston - Acton Inc.2026-05-04 · FEI 1000148174Equipment for Environmental Control
- Tan-Alize Kozmetik ve Temizlik Urunleri Sanayi ve Ticaret A.S.2026-02-27 · FEI 3004135088Air filtration system lacking in production area
Show 4 more
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.46 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 4 observations tie this way. The highlighted sentence is the matched wording.
Family Pharmacy of Statesville2020-02-12 · Observation 9
Air is recirculated to production areas, without adequate measures to control recirculation of dust. Specifically, your uncontrolled lab ceiling vent had visible dust and the filter alarm in your [(6) (~) I hood indicated that filters in this hood containing both scales needed to be changed. This area is where you prepare the following non-sterile drug products: 1. Metronidazole 4%, Lidocaine 5% topical ointment lots: •10232019@1 •12122019@6 …
This observation opens with FDA's standard wording for 21 CFR 211.46(c).
Dr. Reddy's Laboratories Ltd.2019-08-20 · Observation 5
OBSERVATION 5 Equipment for adequate control over air pressure, micro-organisms, dust, humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product. Specifically, The "Air Flow Visualization for Clean Room / Zones" document #SOP-DFTO-QA-0041, dated 23 May 2019 defines Unidirectional flow as follows, "An airflow moving in a single direction, in a robust and uniform manner, and at …
This observation opens with FDA's standard wording for 21 CFR 211.46(b).
PharMEDium Services, LLC.2018-01-05 · Observation 9
OBSERVATION #9 The production area air supply lacks an appropriate air filtration system. ****THIS IS A REPEAT OBSERVATION FROM THE 2013 INSPECTION**** Specifically, A review of the firm's dynamic smoke study videos, dated March 2017 of the ISO 7 cleanroom environment certification, indicated that the pressure differential (airflow) between the cleanroom and ante rooms appeared neutral. According to the smoke study report, signed by QA on …
This observation opens with FDA's standard wording for 21 CFR 211.46(c).
Show 1 more
Hospira, Inc.2012-01-04 · Observation 5
Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination occurs during production Specifically, Smoke studies are not representative of actual production practices which assess whether or not appropriate air changes and laminar air flow exists and can be maintained in a Grade A filling area. On 12/2/2011 I observed an intervention on the [illegible] line at the needle assembly hopper during …
This observation opens with FDA's standard wording for 21 CFR 211.46(c).
Warning letters stating a violation of 21 CFR 211.46
1 warning letter FDA posted states a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your firm failed to provide equipment for adequate control over air pressure, micro-organisms, dust, humidity, and temperature when appropriate for the manufacture, processing, packing, or holding of a drug product (21 CFR 211.46(b)).”
- Right Value Drug Stores, LLC dba Carie Boyd PharmaceuticalsIssued 2024-12-17
Often cited at the same inspection
Of the 218 inspections where FDA cited 21 CFR 211.46, the share where it also cited each of these sections.
- 21 CFR 211.67Equipment cleaning and maintenance97 (44%)
- 21 CFR 211.22Responsibilities of quality control unit91 (42%)
- 21 CFR 211.192Production record review88 (40%)
- 21 CFR 211.160General requirements83 (38%)
- 21 CFR 211.113Control of microbiological contamination81 (37%)
- 21 CFR 211.42Design and construction features78 (36%)
Ask FDAgent about 21 CFR 211.46
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.46; FDAgent quotes that sentence exactly.