Skip to content

Dr. Reddy's Laboratories Ltd.

P1 To P9 & Q1 To Q5, Phase - Iii, Vsez, Duvvada, Visakhapatnam, India

FEI 3006549835DUNS 650446243

Company: Dr. Reddy's Laboratories Limited · Linked by exact D-U-N-S match (650562841) in FDA registration data

FDA has 9 inspections on file for Dr. Reddy's Laboratories Ltd. in Visakhapatnam, India (FEI 3006549835), from 2009 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

The most recent OAI inspection ended on Mar 8, 2017. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, Dr. Reddy's Laboratories Limited (D-U-N-S 650562841), has registered 13 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
9, 2009–2024
2 OAI · 5 VAI · 2 NAI
Inspections with 483 observations shown
5 of 9
Form 483s posted by FDA
↗
4 posted
Requested under FOIA
1 request, latest Aug 21, 2019
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    2. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Change control and incident handling

      The responsibilities and procedures applicable to the quality control followed. Specifically, procedure for change control does protocols, handling of incidents and out of trends procedures are. For example, A) The change control to protocols. Addit~ protocol. For example, 1) has two revisions. The revi Protocol Revision information Ver. Approval date Change 01 08 Jun 2020 Original protocol 02 25 Sept 2020 Product changes 03 23 Jan 2021 To in line According to the process validat manufactured would be considered after approval. The process vali tested for viscosity to go from failing 2) include a reference to the placebo 3) The placebo batch e 1ent11cat the requirement numbering system does not have a record for B) The handling of incidents procedure is not. For example, 1) Incident 200374932 for major with in- The handling of incidents proc On 06/23/2021, the visual inspection for inspection conducted was observed. Incident 200374932 states that due to black particles was trending particles was approximately ~ The initiation date for Incident critical and major visual inspection incident number (200374932). The reports w The SAP system does not include 2) The ma=i~.i~~ ~£.i~b.;rmacopoe 11 1 for the SP test method of pharmacopoeia updates procedure pharmacopeia/ supplements, not implemented after shall be routed through current version of USP test methods the USP monograph. The - was updated in December testing and release of drug There is no incident [illegible] monograph.

    2. Observation 2

      Laboratory control and test methods

      Laboratory controls do not include the establishment specifications, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards. Specifically, the drug substance and drug product plans and test methods. The following examples are for the Drug product, B. The viscosity specification for equipment not being capable of producing precise in-process viscosity failures for three exhibit process conducted. The method feasibility study conducted produce results. The justification provided for C. The particulate matter visible and subvisible procedure makes reference to USP <771> for no method description (i.e. instructions). Incident 2003656855 is for the abnormal obscuration for particle size greater than specification. articles per ml. The measurement D. The related substances test method deviation of mli6 for system suitability method validation was conducted at justification provided for the change. The Analytical method validation related substances by liquid chromatography criteria be the same. The method validation, transfer and samp - There is no deviation written. There is no scientifically sound data to support E. The test method for ~ system suitability for Assay, Pres During [illegible] batch - an incident (200352321) There was a discrepancy between the test method system suitability requirement template was NM-. The correction for the test method. The correction is not validated is NMT•. F. [illegible] from a theoretical batch size of - inspection of filled and sealed containers by using July 16, 2021, was updated to change failed to provide scientific evidence demonstrating to detect particulate matter of your theoretical. The following example is for the Drug substance, G. The test method fo- SP for enantiomeric pu~od system suitability requirements of signal

    Show observations 3 to 8
    1. Observation 3

      Environmental monitoring deficiencies

      Aseptic processing areas are deficient regarding the system. Specifically, you failed to provide scientific justification environmental monitoring process represent the 4) "Re-evaluation for viable monitoring sites 24, 2019. You failed to provide a robust - Equipment ID: 2604824) that could negatively impact aseptically filled [illegible] led for viable monitoring. viable monitoring as the 3) Difficult to clean surfaces identified for environmental monitoring. Examples [illegible] were not interviewed 5) You failed to perform a risk evaluation for not conducting viable personnel monitoring for aseptic filling operators who participate in aseptic filling. Aseptic process qualification for the Grade C area consist PR-0133). During participation, viable monitoring for personnel is not conducted. You failed to perform an assessment of the human flora recoveries and impact control for your Grade C area. Examples active and settle plates from roo nishinomyaensis, Staphylococcus haem pathogen recoveries from the Grade C area are not investigated unless alert and action levels are observed. Furthermore, integrity [illegible] misused by aseptic filling operators. The rationale for not 6) Viable monitoring selection for Grade C filling "FT9PRPQP087-00", effective December 22, 2021, during media fill simulation for viable monitoring: H. Human-Machine Interface (HMI serial number: frequently touching the HMI during production simulation. A scientific justification why the HMI is not monitored was not provided. I. Personnel movement was observed between the bottle filling [illegible] and located on the [illegible] was not provided. Your environmental monitoring process is not robust products.

    2. Observation 4

      Aseptic/sterilization validation gaps

      Procedures designed to prevent microbiological contamination did not include adequate validation of the aseptic and sterilization process. Specifically, your c~ent qualification ~onitoring of the provide assurance that your current process control 4) against newly added items. Examples After location cha adequacy of your justification why validation has not been conducted. During- development studies and Cl in the groove of the environment for the Your failed to provide assurance and is free of viable microorganisms. 5) [illegible] or Grade C roo 17 is inadequate. You failed to evaluate against the placed in the room. Additionally, conditions of the r calibration dat of calibration date 6) You failed to adequately challenge you utilized to items used on your distribution studies wer 002-00'. During 7) risk assessment was conducted, however, you material and

    3. Observation 5

      Supplier certificate validation lacking

      Establishment of the reliability of the component supplier's report results are not appropriately validated at appropriate. Specifically, results are taken from the manufacturer an appropriate interval. Your procedures do include the requirement for Packaging Material (SOP~C-0094) at a specified Materials (SOP~C-0113) and Sampling procedures allow for test results to be taken from availability of in-house testing facility. There is no the manufacturer certificate of analysis are validated Your firm manufactures drug products sterile injectable Reduced Testing Procedure for Raw Materials and applicable for submission batches/ regulatory fil packaging materials, etc. used in those batches. The following materials used in the manufacture In the last two been used in the manufacture of approximately were packaged and shipped to the United States

    4. Observation 6

      Analytical method validation gaps

      The accuracy, specificity and reproducibility Specifically, not all the drug substance and drug documented. For example, C) verification, validation, or transfer include a. Viscosity Profile (As a function of - b. Particulate matter for sub-visible D) Spectroscopic identification test has not been verified for -

    5. Observation 7

      Inadequate investigations and CAPAs

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, investigations into atypical recoveries Microbiology Head of Department, investigations recoveries. Per your "Microbial Identification Program", objectionable microorganism will be investigated. recoveries in the Grade C area are not investigated. The where is located: Gardnerella vaginalis, Past pneumotropica, Additionally, investigations into any unexplained appropriate root cause and implement adequate 8) Investigation into Incident 200355767 investigation fai • .. 4 4 .. contamination arising from the number compounding of injection compounding ro covered: micrococus lutes and Rothis mucilaginosa. handling of media plates during transfer, and the increase compared to routine production. You failed to establish the number your compounding room. You failed to evaluate previous recoveries to ensure your compounding room was not exhibiting environmental warning trends. 9) You failed to establish an adequate corrective and preventative action for failure personnel in evaluating critical maintenance breakdown conducted on the - 200355914 initiated September 6, 2020, attributed to maintenance being performed potential root cause into the excursion was the pressure differential fluctuations prior to product filling. Your corrective action was to update work instruction impact assessment section. Environmental trending was not conducted to ensure your clean room was not trending out of environmental control. A scientific justification was not provided for the investigation inadequacies. 10) You failed to implement an adequate corrective and 200358029. On ~~020, during mug/vial bate~~ Alert recov area. The identified and the operator forgot to knowledge justifying the a was to revise "SOP-FT09-PR-0015", incident date). You failed to implement an adequate corrective action to assure that your production employees are knowledgeable in their job functions and can adequately perform their duties in a manner that would not negatively impact aseptically filled products. 11) Incident 200361222 initiated on November 27, your env filling of Grade C filling room recovered Curvuleria lunata. cleaning and conduct settle plate monitoring for the room. justification detailing a reason why surface and active air monitoring was failed to provide assurance that your clean room was brought back to established operating conditions.

    6. Observation 8

      Cleaning/WFI and cross-contamination risks

      The control systems necessary to prevent contamination Specifically, you failed to establish detailed instructi Injection (WFI). Prior t and after bat. ucket from the oom ning is conducted by dipping a Ii strokes. Per your cleaning operator, the WFI water dirty. Scientific knowledge demonstrating the adequacy of your potential cross contamination from the is lacking. The effectiveness of your cleaning process and microbes that could negatively impact your aseptically filled product.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      QC unit lacks investigation authority

      OBSERVATION 1 The quality control unit lacks authority to fully investigate errors that have occurred. Specifically, On 14/08/19 while observing the routine aseptic filling operations being performed in the [ at approximately ®® we observed a small accumulation of liquid, pooling (approximately 5-10 ml) beneath a support structure that holds the ®® in place. There appeared to be a small steady stream of liquid moving downward on the support. The Associate Director of Quality Assurance initially explained that this was due to condensate and the aseptic filling process and operations was not terminated. However, it was determined that the leakage was due to a hole in the ©“ tubing that is connected to the At approximately a production operator repositioning the ®@ tubing by pushing the tubing upward onto the connecting tube such that the hole stopped dispelling liquid out. There was an additional placement of a zip tie (now a third zip tie) to re-secure the tubing onto the tube. The repositioning of the ® tubing and the addition of a third zip tie appeared to address the leaking ®® into ®® finished drug product. Not until after we communicated that it appeared that they were filling non-sterile finished drug product did the Associate Director of Quality Assurance state (at ®®) they would "abort" the batch.

    2. Observation 2

      Sterilization process not adequately validated

      OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the sterilization process. Specifically, The "Performance Qualification Protocol for [ A" document #FTAPROP366-00 dated 05/05/2016 includes the following documented objective: "To demonstrate that the ©f a) : A; i ©)@ Be)" is consistent and sufficient to the bearing equipment Id PR-E340. The scope of the qualification includes, but is not limited to, ®® concentration verification during [B15] cycle, warm-up status during cycle and "Microbiological monitoring data of pre & post study." The load configuration consisted of [illegible] number of items (e.g., containment parts & utensils); specifically the protocol establishes that it "...shall be ®". The current "Performance Re-Qualification Report for [lin(ly)] (PR-E346) document #VALRP-FT-07-000118 dated 27/03/2019 load configuration is not consistent with the validated load configuration performed in 05/05/2016, for example: FTAPROP366-00; VALRP-FT-07-000118; Brief description 05/05/2016 / location | 27/03/2019 / location [illegible table content] In addition: a. There are no explicit details to describe the specific placement of the various items and equipment parts that are placed inside the [during] the 05/05/16 initial performance qualification. And, there is no manner with which the current 27/03/2019 load configuration can be compared to the original 2016 validated load configuration in support of the process. The Team Leader MSAT and Quality Assurance Team Leader Manufacturing & MSAT Team member confirmed there are no diagrams or photographs that assist to illustrate the load configuration; b. The "Cycle Development for [©]" protocol dated 12/05/16 objective include but not limited to the "...develop parametric cycle parameters from a series of progressive studies" and "to qualify the developed cycle through biological indicator (BI) challenges." The acceptance criteria for the BI challenge consists of placement "where the BI's look the longest time to change", "where the temperature were both highest and lowest", "placed [illegible]". However, there were no other considerations with respect to determining or evaluating other possible locations to be [illegible]; the current BI challenge locations may not represent the worst challenge locations and there may be other challenge locations that the firm may not be knowledgeable of with respect to where the [illegible] did not contact, and/or the [illegible] was less than adequate to penetrate the ®® interior surfaces;

    Show observations 3 to 5
    1. Observation 3

      Unjustified deviations from procedures

      OBSERVATION 3 Deviations from written production and process control procedures are not justified. Specifically, There is an "Incident Investigation Report" document #WI-DFTO-QA-0118 regarding the manufacture of an injection ®® mg/vial B. No. [in Line]. The incident consisted of a microbiological excursion dated 10/01/2019 that occurred at regarding L21SMG10 and L21SMG2 at 15:43 from the (PR365A-1). For microbiological counts for L21SMG10 and L21SMG2 in Grade A area was TNTC and (§) CFU, respectively. The microbiological count in the [illegible] was © CFU/m2 (mold). The genus and species were identified as Bacillus species for L21SMG10 and Sphingomonas paucimobilis for the latter two locations. It was determined that the EM microbiological sampling swabs were not placed in the required configuration (e.g., individually placed), consequently they were not subject to [illegible]. In addition: d. There are several in-process control questionnaire checklists that require the In-Process Quality Assurance (IPQA) team to verify prior to commencing the aseptic fill operations. One of the questionnaire checklist is the "Check List for Review of Aseptic Operations, Practices in the Critical Area" document #FORM-DFTO-QA-0107 dated 03/08/2019. The checklist includes the following i.c., = as per the validated [illegible]. The above observation document, despite the establishment of the IPQA checklist, there is a gap with the IPQA verification process; The "Operation of Integrity Tester (Skan Wireless GT) (Line)" document #WI-FT07-PR-0202, dated 09/08/2019 establishes the visual verification process of the © which includes a verification for "(rupture/puncture/pin hole) color change, cleanliness of ®®". The visual verification is documented in the "Pre Check Points To Start Integrity Test (Line §)" Form-FT-07-PR-0298. The pre-checks are performed, however the Associate Director of Quality Assurance confirmed that QA does not review and approve the visual verification to assure that the requisite evaluation is performed and rightly obtained.

    2. Observation 4

      Deficient aseptic area air supply monitoring

      OBSERVATION 4 Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, The "Performance Requalification Protocol of [Fr *]" document #VALPR-FT07-000030 dated 27/03/2019 includes Non-Viable Particle (NVP) count monitoring. "The objective of this test is to verify that the concentration of airborne particles inside meet Grade A requirements." A "Rationale for the Selection of NVPC Location" establishes, for example, the locations for includes [illegible]. The locations are near to [illegible]. During routine aseptic filling operations, there are no NVP [instruments] located between the [stoppering station] and the [filling area]. The distance between the NVP [location] near the [illegible] [illegible]. a. Following the pit stoppering station the filled vials are automatically transferred to the [illegible] via a conveyor system. There is no NVP monitoring performed during the transferring / conveying process of the vials to the [illegible]; and, b. There is no record to document that the filled vials are maintained in a Grade A (ISO-5) environment during the transferring process to the [illegible] which precludes from substantiating that the Grade A environment is maintained to the requisite specification. The "Environmental Monitoring in Injectable of Block *" document #SOP-FT07-PR-0172, dated 02/11/2018 establishes monitoring of NVP of critical area that include manufacturing room #[illegible]. The standard procedure defines an "In operation" state as, "...the conditions where the installation is functioning in the defined operating mode with the specified number of personnel working." The manufacturing room is a classified Grade D in an "In operation" state. As established in the standard procedure, NVP monitoring is performed on a [illegible] basis. There is no document to describe the scientific rationale that established the NVP monitoring frequency. In addition: e. In 2018 and 2019 there were a total of [illegible] batches of finished drug products manufactured in room #[illegible] i.e., [illegible] and [illegible] batches, respectively. In 2018 and 2019 NVP monitoring of the manufacturing room was performed [illegible] times, respectively; f. NVP measurements are taken from separate locations in manufacturing room (Grade D during in operation conditions). NVP sampling locations include [illegible] of manufacturing room and from a set between the [illegible] The Associate Director of Quality Assurance confirmed there is no personnel activities that occur at [illegible] of the sample locations of the room; and, g. The initial [line] that is used to transfer the bulk solution to the [illegible] and [illegible] that is used to sterilize the finished drug product is manually connected next to the [illegible] within a Grade D environment. As previously noted, NVP monitoring locations do not include the personnel manual activities that occur within the area where the initial [line] is connected.

    3. Observation 5

      Inadequate environmental and airflow control

      OBSERVATION 5 Equipment for adequate control over air pressure, micro-organisms, dust, humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product. Specifically, The "Air Flow Visualization for Clean Room / Zones" document #SOP-DFTO-QA-0041, dated 23 May 2019 defines Unidirectional flow as follows, "An airflow moving in a single direction, in a robust and uniform manner, and at sufficient speed to reproducibly sweep particles away from the critical processing or testing area." In addition, the standard procedure establishes "Airflow should be unidirectional in nature and should show uniform flow patterns with minimum turbulence or eddies. Any turbulence or eddies should be justified with environmental monitoring studies or other justifications." Furthermore, the "study is to evaluate the impact of all the production interventions performed by human, machine during routine operation on air flow pattern demonstrated at operation." Despite the establishment of the standard procedure, the air flow pattern evaluations document a number of instances where the airflow does not demonstrate a "unidirectional" uniform manner of movement and/or the evaluations lack the ability to demonstrate the unidirectional airflow is appropriately achieved and maintained during the dynamic operations. This ultimately prevents the ability to "evaluate the impact of all the production interventions..." upon the "air flow pattern demonstrated at operation." Note: the summary information provided in the following table is not intended to be an all-inclusive and/or exhaustive list of concerns.

  4. VAIObjectionable conditions found; FDA took no regulatory actionDevices · Compliance: DevicesPosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Validation acceptance criteria missing

      Acceptance criteria were not established prior to the performance of validation activities. 4 A Ps . : (b) (4) . Specifically, is not clear how your firm determined the acceptance criteria for the Functionality Testing (Break loose force &, Glide force) conducted as part of finished product release specification for IB Injection®® mg@nL. For example, your firm explained that the worst-case condition was considered for the applied injection @@ “based on the container size as part of the criteria to test the anples. Your data was only obtained 4% the” “samples from stability study for 24 months for’ (Batches: ed as reference data for Break loose force of @ Newton and Glide force of Newton. ~ . PR) (b) . However, your firm established the test limit for Break loose force as @ Newton and for Glide force as Newton as the finished product release specification test limits. This was not supported by scientific data that demonstrated the impact to the end user or to the finished product functionality.

    2. Observation 2

      Design not translated into specs

      The device design was not correctly translated into production specifications. Specifically, your Acceptance Quality Limit [AQL] does not take into account the component critical dimensions specification during receipt of components for the manufacture of Injection ©@ ho @nL such as®® and stoppers.

  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate sealing process controls

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Your Quality Unit failed to implement adequate and reliable controls for ensuring that distributed liquid injectable drug products or any of its components always comply with the quality they represent to possess. All the following adverse incidents correspond to sterile liquid drug product lots that were sealed in the sealing equipment PR-E007. In January, 2018, your firm recalled one (1) lot of Docetaxel Injection USP 20 mg/mL (USA market); Lot H7044; expiration date 05/2019, due to consumer complaints related to critical sealing defect (i.e. seal and stopper comes off the vial, making vial wide open and exposed). This critical defect was acknowledged in each of the four (4) complaints reported for the affected lot. First complaint was received on 10/20/2017. The complainant stated that “had seven (7) vials of Docetaxel Injection USP 20 mg/mL; Lot H7044 where the entire top comes off when trying to administer the medication and the whole vial is wide open, exposing the inside of the vial”. Your Quality Unit initiated a manufacturing Investigation Report (IR) 200263810 on 10/21/2018. No Field Alert (FAR) was submitted to the agency. IR 200263810 disclosed that all in-process controls and released testing, for Lot H7044 were as expected. However, based on the complaint nature, the investigation identified major contributors for the confirmed critical sealing defects. None of the referenced sealing critical process parameters were validated in the sealing equipment PR-E007 by the time the referenced complaint was received. As part of the manufacturing investigation IR 200263810, representative reserve samples of lots were evaluated for seal removal. It was identified that one (1) vial from lot of Injection (Indian market); Lot [illegible] showed also the critical sealing defect. As corrections, your Quality Unit proposed the implementation of manual functionality test during sealing activity and qualification of sealing critical process parameters. Second complaint for Docetaxel Injection USP 20 mg/mL (USA market); Lot H7044 was received on 11/08/2018. The complainant stated “the whole top of the vials is loose and when tried to pull the cap off, the whole metal part comes off (aluminum seal)”. Your firm initiated the manufacturing IR 200266437 and submitted a FAR to the agency on 11/09/2018. For the period from 10/20/2017 (first complaint was received) to 11/09/2017 (second complaint was received) approximately [illegible] vials of Docetaxel Injection USP 20 mg/mL; Lot H7044 were distributed into USA market. After the second complaint received for Lot H7044, your Quality Unit determined to recall this lot. Additional complaint was received on 12/26/2017 for Injection [illegible] mg/mL (USA market); Lot [illegible]; expiration date [illegible]. The complainant reported two (2) observations: vial 1 - liquid leak found between the cap and the vial; vial 2 - seal came off from the vial where the cap remains on the seal. Manufacturing IR 200273645 was initiated and a FAR was submitted to the agency on 12/28/2017. The IR 200273645 disclosed no discrepancy during the manufacturing process of Lot [illegible]. All the in-process controls and released testing for Lot [illegible] were as expected. As part of the investigation, the reserve samples of Lot [illegible] were also inspected, and no loose seal or leakage was observed. Your Quality Unit concluded that if seal is on its place, the vial is integral. No additional actions were considered. As corrections, your Quality Unit defined for removal of [illegible] in alignment with the supplier specification (06/2018); implemented functionality test (02/2018), and carried out validation activities of the sealing critical process parameters [a vials (12/2017)]. The lack of qualifyin

      Shortened here; the PDF has the full text.

    2. Observation 2

      Failure to investigate OOS across batches

      Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product that may have been associated with the specific failure or discrepancy. Specifically, investigations into confirmed Out of Specification (OOS) results and identified manufacturing equipment defects were not included and considered for batch disposition of previously manufactured products, on the affected manufacturing equipment. The Quality Unit did not expand the sampling and testing program on the affected batches observed with low or OOT assay results, manufactured with known equipment defect. Tablet, mg, batch# was rejected due to a confirmed OOS (A.V.= 1, exceeding the A.V. value of [illegible] for Uniformity of Dose (UOD). This batch also yielded low assay results. The OOS investigation 310016050 was initiated on 31Aug18, identified a defect on the seal to the machine (PR-E648), resulting in poor operations on the [illegible]. The seal leak resulted in the process control (HMI) to run the [illegible] to maintain the [illegible] deviating from the typical [illegible] on [illegible]. The OOS investigation identified low assay values on previously manufactured batches of [illegible] Tablets, manufactured on the same defective Machine (PR-E648). Batch numbers [illegible] expiration date [illegible] reported lower assay results of [illegible] respectively (assay specification limit = [illegible]). During the manufacturing of the previously manufactured Tablet batches the [illegible] were operating near the [illegible] indicating the same equipment defect. No additional tests were performed to justify the release of the impacted batches, manufactured on the equipment with known equipment defect. All impacted batches of [illegible] Tablets were released for distribution to USA market. Repeat Observation from WL 320-16-02 & FDA-483 March 2017.

    Show observations 3 to 8
    1. Observation 3

      Inadequate aseptic procedures and media fills

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established or followed. Your control procedures SOP FTDQA007-02; dated on 02/28/2018 “Aseptic Process Simulation (Media Fill)” and SOP FT07-QA-0022; dated on 07/31/2018; version 2.0 “Handling of Interventions during routine production activity” were found inadequate. Specifically, these control procedures do not require a periodic simulation of new and highly critical intervention (corrective intervention) observed during routine commercial process. A. For example, Incident Report (IR) 200241685 was initiated on 05/29/2017, due to a new corrective intervention observed on 05/27/2017 by two (2) operators in PR-E007 filling Line operation of drug product Injection [illegible] mg/vial; Lot [illegible] expiration date [illegible]. The fill volume adjustment and filling operation were completed. The IR 200241685 identified a damage in the [illegible] as the root cause for this new corrective intervention. Same corrective intervention was also carried out on 07/04/2017, in PR-E007 filling Line operation of drug product Injection [illegible] mg/vial; Lot [illegible] expiration date [illegible]. However, no incident report was initiated to assess the impact of the intervention over the aseptic filling operations for Lot [illegible]. Moreover, no root cause was identified to prevent reoccurrence of having a mechanical intervention in the PR-E007 while processing. This corrective intervention was simulated during set-up process of the PR-E007 filling Line in two (2) successive media fill Lots (dated on 05/31/2017) and (dated on 06/07/2017). However, your firm simulated the intervention during the set-up process of the filling Line instead of simulating it during aseptic filling process, which is where the worst condition is represented. Moreover, there is no evidence in the media fill batch records (Lots [illegible]) which demonstrate the corrective intervention was performed by two (2) operators. Your Quality Unit failed to include the intervention in the list of the corrective and highly critical interventions that should be periodically simulated as part of your media fill program. Your firm has carried out approximately nine (9) media fill runs in aseptic filling Line PR-E007 since the corrective action was observed on 07/04/2017. Repeat Observation from WL 320-16-02. B. There is no assurance that your process simulation studies (media fills) performed in the PR-E007 filling Lines are truly representative of the conditions observed and/or that might occur during routine aseptic filling operations of vials. This is evidenced in that, although corrective and inherent operator's interventions are simulated during the media fills, the duration at which these interventions are simulated is not established based on an historical and/or retrospective evaluation. Your current practice does not ensure the extension of each of the interventions is accurately simulated during the aseptic-process (media fill) runs. C. The control procedure SOP FT7QC247; dated on 05/29/2018; “Microbiological Viable Monitoring Program” establishes the following rationale for selecting the sample sites for microbiological monitoring into the ISO 5 area of PR-E007: * Sites where activities that contribute spread of contamination; * Sites, which if contaminated, have adverse effect on product quality. Per control procedure SOP FT7QC247, [illegible] located in ISO 5 area of PR-E007 was selected for surface sampling monitoring. This location was selected to ensure aseptic conditions of the filling area. The control procedure SOP FT7QC247 was found inadequate, in that it does not require that surface sampling (swab sampling method) must be collected from the [illegible] that was in use during the aseptic filling process. For example, on 10/29/2018, I witnessed the aseptic filling process of Injection [illegible] mg/vial; Lot [illegible]. This lot was

      Shortened here; the PDF has the full text.

    2. Observation 4

      Deficient airflow visualization studies

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. The control procedure SOP FTDQA004-00; dated on 09/14/2017; “Air flow Visualization for Clean Rooms/Zones” establishes/requires: * Section 6.3.18.1 — The study is to evaluate the impact of all the production interventions performed by human, machine during routine operation on air flow pattern demonstrated at operation. * Section 6.3.18.20 — Interventions: all the aseptic manipulations and interventions shall be captured during the dynamic smoke study i.e. inherent interventions that occur during operational conditions and corrective interventions that may occur when machinery is not operating. Nonetheless, your air flow pattern study conducted during filling equipment assembly and process for PR-E007, and documented in the DVD; Doc. FTTAPRPQP235-11(A) “Air Flow Visualization Study; Vial Line Blockfilling Injection” dated 01/11/2017, utilized to ensure unidirectional airflow during manufacture of aseptically filled drug products, is deficient in that it does not demonstrate how the air flow pattern of the ISO-5 area of the PR-E007 vial filling Line is affected by a new corrective intervention position from [illegible] to [illegible] or vice versa. Per media fill run DVD; Lot [illegible] (dated on 05/31/2017), the corrective intervention was performed by two (2) operators. One of the operator was in the [illegible] of the filling Line and the other operator was in the [illegible] of the filling Line. Both operators simultaneously carried out the intervention in the ISO-5 area of the PR-E007 vial filling Line. Repeat Observation from FDA-483 March 2017.

    3. Observation 5

      Failure to review unexplained discrepancies

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, your Quality Unit failed to conduct a comprehensive evaluation and implement appropriate and effective corrective and preventive actions to prevent reoccurrence of aborted HPLC sequence events. During the period between 01Jan2018 to 15Oct2018, there were approximately 175 events identified as “repeated incidences” from QC, including at least 19 events due to column conditioning and 15 poor column performances that resulted in aborted or invalid HPLC sequence runs. Based on your assessment and identified root causes, insufficient actions were taken by the Quality unit to ensure the robustness and suitability of the analytical test procedures and the equipment. Incident events with similar root causes were not thoroughly reviewed for historical trends and corrective actions were not implemented to reduce the occurrences of atypical events from similar root causes. Repeat Observation from WL 320-16-02 & FDA-483 March 2017.

    4. Observation 6

      Insufficient employee training and competency

      Employees engaged in the manufacture and processing of drug product lack the training and experience to perform their assigned functions. Specifically, A. The firm’s training program does not provide comprehensive trainings to conduct the assigned job responsibilities. The training programs do not define the requirements for the on-the-job trainings or the qualifications for technical procedures, including operation/calibration of dissolution apparatus, GC, pH meter, Karl Fisher, etc. The self-conducted, SOP trainings are required for most operations and there are no training assessments conducted to verify the training effectiveness. Firm’s personnel showed insufficient knowledge of the written procedures on the routine operations for the assigned job, resulting in numerous incidences of atypical events. B. There are insufficient trainings provided for observed procedural or practical deficiencies, identified from atypical incident events. Refresher trainings are not always required or provided to all affected personnel, for the root causes identified in the reoccurring atypical events. Repeated atypical events from similar root causes have resulted in numerous aborted HPLC sequence runs. During Jan-Oct 2018, I've identified at least 34 repeated atypical events, related to insufficient handling of HPLC columns, 19 aborted sequence runs from improper column conditioning and 15 events from poor column performance.

    5. Observation 7

      Batch records missing operator identification

      The batch production and control records are deficient in that they do not include identification of persons performing each significant step in the operation. Specifically, per media fill run DVD; Lot [illegible] (dated on 05/31/2017), the corrective intervention carried out by two (2) operators. One of the operator is in the [illegible] of the PR-E007 filling Line and the other operator is in the [illegible] of the filling Line. Both operators simultaneously carried out the intervention in the ISO-5 area of the PR-E007. However, the media fill batch records for Lots [illegible] and the commercial batch records for aseptic process of Injection [illegible] mg/vial; Lots [illegible] aseptically filled in PR-E007 filling Line only document the name of one (1) manufacturing operator when the corrective intervention was performed.

    6. Observation 8

      Delayed Field Alert Report submission

      A Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application. On 10/20/2017, your Quality Unit received one (1) customer complaint related to a critical sealing defect (i.e. observed in seven (7) vials of Docetaxel Injection USP 20 mg/mL (USA market); Lot H7044; expiration date 05/2019). Manufacturing Investigation Report (IR) 200263810 was initiated and identified major contributors for the confirmed critical sealing defects. Investigation IR 200263810 also disclosed that none of the referenced sealing critical process parameters were validated in the PR-E007 filling Line (sealing equipment) by the date (10/20/2017) the complaint for Lot H7044 was received. PR-E007 was used during the sealing process of Lot H7044. Your Quality Unit did not submit a FAR to the agency until they received on 11/09/2017, a second complaint reporting the same critical sealing defect in lot H7044. For the period from 10/20/2017 (first complaint was received) to 11/09/2017 (second complaint was received) approximately [illegible] vials of Docetaxel Injection USP 20 mg/mL; Lot H7044 were distributed into USA market. Lot H7044 was recalled.

  6. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Aug 21, 2019. It asked for a Form 483.

  • Inspection date not given

    1 request.

    1. Aug 21, 2019FDA-FOIA-2019-7565Form 483Open

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 2 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 9 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
Dr. Reddy's Laboratories LimitedD-U-N-S 650562841

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Dr. Reddy's Laboratories Limited (D-U-N-S 650562841) as the registrant for this site and 13 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Other FEIs recorded as Dr. Reddy's Laboratories Ltd.

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3006549835 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3006549835. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.