Dr. Reddy’s Laboratories Limited
(Village), Ranasthalam (Mandal), Srikakulam, Andhra Pradesh, India
FEI 3009193040DUNS 860037244
Company: Dr. Reddy's Laboratories Limited · Linked by exact D-U-N-S match (650562841) in FDA registration data
FDA has 6 inspections on file for Dr. Reddy’s Laboratories Limited in Srikakulam, Andhra Pradesh (FEI 3009193040), from 2014 to 2025. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, Dr. Reddy's Laboratories Limited (D-U-N-S 650562841), has registered 13 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 6, 2014–2025
- 0 OAI · 3 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 6
- Requested under FOIA
- 3 requests, latest Dec 22, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetDrug Product ManufacturerPosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to investigate OOS results
OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, (b)(4)(b)(4) A. On 4/28/2025, you recorded non-conformances 310028189 and 310028200 for (b)(4)(b)(4)(b)(4) for Dissolution by HPLC. The OOS results were recorded (b)(4)(b)(4)(b)(4) for Batch No’s. (OOS No. 310028189) and (OOS No. 310028200). Both the batches failed the dissolution test for Tablet Unit- % (Batch No. (b)(4)(b)(b)(4)(b)) and(4)% (Batch No. ) against the Specification NLT (not less than) % (Q)(4)(b)(4)(b)(b)(4) of the labeled amount of dissolved in (4)(b)(4)(b)(4). The above two batches were analyzed in a set of three batches, Batch No’s; (b)(4)(b)(4)(b)(4)(b)(6) in that order) by the same analyst ( ). In Phase I, you confirmed the OOS result via Re-Measurement Testing. No root cause was identified in Phase I. You assumed that “OOS result might be the cause of paddle not placed for subjected unit (Unit ”. Based on this hypothesis, you repeated the analysis with fresh sample preparation and based on the passing results (DS- % for Batch No. , DS- % for Batch No. ), you invalidated the initial OOS results and released the batch. You carried out Phase II Manufacturing investigation only to verify the various process (b)(4)(b)(6)(b)(4)(b)(4) parameters. Your Site QA Head stated that the is on test and batch (b)(4)(b)(4)(b)(4) or batch whichever is earlier is tested for description, assay, and (b)(4)(b)(4)(b)(4) KF. You stated that the for the subject batches Batch No’s and were 2 and 3 batches for 2025 and did not need testing. (b)(6)(b)(4) On 12/9/2025, your analyst reviewed FORM-FS01-QC-0358 Version 4.0, Check List for the Dissolution Analysis for the dissolution test for the implicated batches and confirmed that the paddles were placed as per the numbering. The analyst also confirmed in the Check List that Tablets were disintegrated completely at the end of the run. These recorded information by the analyst (at the time of analysis) in the Check List does not support the root cause and retesting. (b)(4)(b)(4)(b)(4)(b)(4) The Batch No’s and were used to manufacture (b)(4)(b)(4) Batch No’s (Mfg. date 4/6/2025 and Expiry date (b)(4)(b)(4) and (Mfg. date 4/15/2025 and Expiry date (b)(4) respectively. You shipped a total of bottles ( tablets) of the above batches to the US market. (b)(4) B. On 1/23/2025, you recorded a major deviation, DV2000020047 for (b)(4) mg for Dissolution by HPLC. The deviation was recorded for Batch No. when an (b)(4)(b)(4) extraneous peak at was recorded for Tablet Unit- % against to standard area (b)(4) response, Specification NMT %. Remeasurement of the Same vial confirmed the extraneous peak, but this peak was missing from the Bench top solution. Phase I investigation did not reveal any assignable root cause. You concluded that the dropper (that was used to transfer the test solution into the HPLC vial) could be the most probable cause for the extraneous peak. You then made new sample and based on the passing dissolution test values, you invalidated the initial results and released the batch. The Batch No. was used to manufacture (b)(4)(b)(4)(b)(4) Batch No. (Mfg. date 1/11/2025 and Expiry date (b)(4)(b)(4)(b)(4)(b)(4) You shipped a total of bottles tablets) of the above batches to the US market. (b)(4) C. You have received multiple market complaints for and made several markets recalls on a select campaign batches. You unsubstantiated the Market Complaints for (b)(4) the batches that were not part of this campaign. E. g. on 1/28/2025 you (b)(4)(b)(4) received a Market Complain # 200433853 for Batch No’s. (b)(4) and . The pharmacy reported, “One tablet with the incorrect imprint on it which (b)(4)(b)(4) matches the strength however the color of the tablet is correct as similar to other tablets.” These two batches were not part of the campaign that were i
Shortened here; the PDF has the full text.
- Observation 2
Unrequalified tablet compression machines
OBSERVATION 2 Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. (b)(4) Specifically, you qualified your Tablet Compression Machine ID # PR034 and (b)(4)(b)(4) ID # PR034 in Room as per the Performance Qualification Report FTS1PRPR034-01 (Effective date 8/8/2013). On 3/16/2024 the ID # PR034 underwent (b)(4)(b)(4) breakdown during the manufacturing of Batch No. . You (b)(4)(b)(4) replaced ID # PR034 with a different ID # PR182 and continued with the manufacturing of Batch No. . (b)(4) As of 12/12/2025, you have not requalified your Tablet Compression Machine ID # PR034 and (b)(4)(b)(4)(b)(4) ID # PR182 assembly in Room . The make and model of the (b)(4)(b)(4) (b)(4)(b)(4)(b)(6) ID’s # are different. Your Head of Production stated that (b)(4) the working principles for are same thus requalification is not needed. (b)(4) You manufacture multiple drug products on Tablet Compression Machine ID # PR034 and (b)(4)(b)(4)(b)(4) ID # PR182 in for the US market. E. g. (b)(4)(b)(4)(b)(4) , , (b)(4)(b)(4)(b)(4) ), (b)(4)(b)(4)(b)(4) (b)(4)(b)(4) , and .
Show observations 3 to 5
- Observation 3
Cleaning validation not revalidated
OBSERVATION 3 Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, you practice cleaning validation for equipment trains for the worst-case molecule. The (b)(4) cleaning validation for your Tablet Compression Machine ID # PR034 and (b)(4)(b)(4)(b)(4) ID # PR034 in was conducted in an equipment train for Tablet as the (b)(4) worst-case molecule as reported in Cleaning Validation Report for Tablets VALRP-FS01-000310 (Effective date 10/6/2020). On 3/16/2024 the (b)(4) ID # PR034 (b)(4) underwent breakdown during the manufacturing of Batch No. (b)(4)(b)(4)(b)(4). You replaced ID # PR034 with a different (b)(4) ID # PR182. After changing the equipment, you did not re-validate the cleaning of the (b)(6)(b)(4) new equipment train. Your Head of Production ( ) stated that the surface area of PR182 ( ) (b)(4) 2 is higher than PR034 ( ). After multiple requests, you were unable to provide surface area (b)(4) calculations for the ID # PR034 for verification.
- Observation 4
Inadequate assay validation and inspections
OBSERVATION 4 Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. Specifically, A. Section 5.10.6 of your procedure, SOP-GLOB-QC-0085 Version 13.0 Good Analytical Practices (b)(4) (Effective date 7/25/2025) requires measurements from each preparation for assay test methods by HPLC. However, you have validated the assay test methods by HPLC from a single measurement from each preparation. E. g. (b)(4) (b)(4)(b)(4)(b)(4)(b)(4) a. Tablets USP mg Assay Method Validation Report No. RP-FS01-000060 Version 2.0 (Effective date 3/27/2020). (b)(4)(b)(4) (b)(4) Linearity of test method was established from concentration range μgm/mL – (b)(b)(4)(b)(4) μgm/mL ( % - % of the standard solution) at intervals with a single (4) measurement at each concentration. You routinely use this test method to release (b)(4) (b)(4)(b)(4)(b)(4)(b)(4) Tablets USP mg to the US market. (b) (b)(4)(b)(4)(b)(4) b. in Table(4) mg/ mg, Assay (by HPLC) Method Validation Report No. RP-FS01-002324 Version 1.0 (Effective date 7/11/2024). Linearity of test method was established from concentration (b) (b) (b)(4) (4) range(4) % to % (of the standard solution) at ntervals with a single measurement at (b)(4) each concentration. You have used this test method for the exhibit batches of (b) (b)(4)(b)(4)(b)(b)(4) Tablet(4) mg/ and(4) mg that are manufactured (b)(4) to support (b) (b)(4)(b)(4)(b)(4) c. in Tablet(4) mg/ mg, Assay (by HPLC) Method Validation Report No. RP-FS01-002337 Version 1.0 (Effective date 7/11/2024). Linearity of test method was established from concentration range to (b) (4) (b) % (of the standard solution) a(4) ntervals with a single measurement at each (b)(4) concentration. You have used this test method for the exhibit batches of (b)(4) that are manufactured to (b)(4)(b)(4) support B. Your procedure SOP-FS01-PR-0067 Version 14.0 Production Procedure and Controls (Manufacturing + Packing) (Effective date 12/13/2023) does not ensure that the visual inspectors are adequately qualified. Section 5.2.30 requires taking units of good tables and add defective tables. These tablets are mixed and used as test kit to qualify the visual inspectors. There is no information about the type of defects and the number of defective tables in the test kit. Review of an inspector evaluation form, FORM-FS01-PR-0328 Version 2.0 executed on (b) (b) (b)(6) 10/11/2025 for an Inspector (6) confirmed that (4) defective tables were added and were (b)(6)(b)(4) identified by the Inspector . However, the form did not have information about the number (b)(6)(b)(4) of good tables used in the test kit. Your Production Head confirmed that it was the standard practice to qualify the Visual Inspectors. Your Production Manager also stated that the firm has created a new procedure to qualify the visual inspector, SOP-FS01-QA-0025 Version 1.0 Inspection Evaluation Process (Effective date 12/7/2025). As of 12/11/2025, you have not implemented the procedure, and you also did not have the test kit. You have recorded multiple market complaints for defective tablets, capsules, and commingled products. E. g. Market Complaint No’s. 200434402 (physical defects in capsules), 200434810 (foreign products), 200425820 (comingled tablets), 200436426 (discolored tablets with black (b)(4)(b)(4) spots), 200433853 (tablet is the correct color, but the imprints match the strength).
- Observation 5
Improper sampling of APIs/excipients
OBSERVATION 5 Written procedures are not followed for the sampling of drug substance and excipients. Specifically, your sampling practices are not scientifically sound and appropriate to ensure that your raw materials conform to established standards of quality and purity. Section 5.5.2.1 of your SOP-GLOB-QC-0113 Version 15.0 Sampling and Testing of Raw Materials (Effective date 5-Nov-2025) requires (b)(4) (b) (4) use of to collect samples from of the containers or bags. You use (b) (4) (b) (4) sterile scoop cm) and spoons to collect the samples for the active pharmaceutical ingredients (APIs). You have recorded multiple OOS results for drug products for related substances where APIs (b)(4) were sampled with sterile scoops and spoons. Some such examples are listed in Table 1. Table 1. Sampling of APIs (select examples) Entry API Batch No. Sampling tool Drug Product Name Batch No. OOS No. Test (b)(4) (b)(4) (b)(4) 1 Sterile scoop 310028627 Related Substances Measuring (b)(4) (b)(4) , (b) (b)(4) (b)(4) scoop and (b)(4) 310028958 Related Substances (4) 2 spoon
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate lab processing for release testing
OBSERVATION 1 Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. ... (b)(4) Specifically, in testing results of (b)(4) Powder (b)(4) mg packed in sachets for exhibit batches/lots we observed: 1. On 16 December 2015, the initial release testing results was generated using manual integration for related substance testing for all three exhibit batches. 2. Different processing methods were used to process system suitability solution, standard, and sample injections for the following release testing and stability samples: (b)(4) A. Powder release testing (b)(4) and accelerated samples: o 3 month, lots o 6 month, lots o 5 month, lots In addition, related substance for assay testing for [illegible], which is a component in (b)(4) Powder (b)(4) mg, was also processed using separate processing methods for system suitability solution, standard, and sample injections during the 3 and 6 month long term and accelerated stability samples, and 5 month accelerated stability sample of exhibit lots. C. Tablets (b)(4) [illegible] mg tablets, lot [illegible] packed in [illegible] and [illegible] count bottles, for nine month long term stability sample. [illegible] 09 mg tablets, lot packed in [illegible] and [illegible] count bottles, for nine month long term stability sample. [illegible] mg tablets, lots [illegible] and for initial release testing sample. [illegible] mg tablets, lot for initial release testing sample.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Dec 22, 2025. Each one asked for a Form 483.
Inspection ending Dec 12, 2025Not classified yet
2 requests. In the inspection history above. FDA has posted its Form 483.
- Dec 22, 2025FDA-FOIA-2025-14294Form 483No records found
- Dec 15, 2025FDA-FOIA-2025-13972Form 483Records released
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Mar 21, 2025FDA-FOIA-2025-2641Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 6 inspections.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Dr. Reddy's Laboratories LimitedD-U-N-S 650562841
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Dr. Reddy's Laboratories Limited (D-U-N-S 650562841) as the registrant for this site and 13 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- DR. REDDY'S LABORATORIES LIMITEDNalgonda, India · FEI 30054479657 inspections7latestMay 24, 2025VAI1 warning letter, Nov 5, 2015
- DR. REDDY'S LABORATORIES LIMITEDSrikakulam, India · FEI 30029490856 inspections6latestJun 7, 2024VAI1 warning letter, Nov 5, 2015
- DR.REDDY'S LABORATORIES LIMITEDVisakhapatnam, India · FEI 30065498359 inspections9latestMay 17, 2024VAI1 warning letter, Nov 5, 2015
- Industrias Químicas Falcón de México, S.A. de C.V. (DR. REDDY'S MEXICO)Jiutepec, Mexico · FEI 30028082973 inspections3latestAug 7, 2015NAI1 warning letter, Jun 3, 2011
- DR. REDDY'S LABORATORIES LIMITEDRansthalam Mandal, Srikakulam District, India · FEI 30053368823 inspections3latestNov 14, 2025NAINone on file
- Dr. Reddy's Laboratories (EU) Ltd.Mirfield, United Kingdom · FEI 30028075443 inspections3latestSep 5, 2025VAINone on file
- DR REDDY'S LABORATORIES LIMITEDPydibhimavaram, India · FEI 30124144621 inspection1latestJul 18, 2025VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDJinnaram Mandal, Hyderabad, India · FEI 30054480305 inspections5latestNov 19, 2024VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDMedchal-Malkajgiri District, India · FEI 30029490998 inspections8latestOct 27, 2023VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDJinnaram, India · FEI 30031844975 inspections5latestJun 16, 2023NAINone on file
- DR. REDDY'S LABORATORIES LIMITEDRanasthalam Mandal, Srikakulam, India · FEI 30111715111 inspection1latestMay 12, 2023VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDSangareddy, Hyderabad, India · FEI 30028068515 inspections5latestMay 5, 2023VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3009193040 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3009193040. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.