FDA has 3 inspections on file for Dr. Reddy's Laboratories in Mirfield, United Kingdom (FEI 3002807544), from 2013 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 7 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, Dr. Reddy's Laboratories Limited (D-U-N-S 650562841), has registered 13 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2013–2025
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- 1 posted 483 not matched to an inspection
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate microbial testing evaluation
Failure to establish adequate specifications, sampling plans, and testing procedures to ensure that raw materials and APIs meet accepted quality standards and are consistent with the manufacturing process. Specifically, A. Your firm failed to perform an adequate assessment to determine whether microbial testing is required for the finished active pharmaceutical ingredient (API). This API is intended for use in the manufacture of drug products and utilizes water as an ingredient during [illegible]. It is intended for US market distribution, and since 2020, batches have been distributed into the US market. Given that this API is intended for use and water is incorporated during [illegible], your firm should have conducted [illegible] or any other evaluation to determine appropriate microbial testing requirements, to assure that the API have the quality, and purity they purport or are represented to possess. B. Your firm failed to perform Burkholderia cepacia testing per USP. Water used as an ingredient during [illegible] and the API is intended [illegible] and since 2020, batches have been distributed into the US market. API is shipped to the firm's main facility in India to be used in [illegible] which are intended to be distributed into the US market.
- Observation 2
Reliance on supplier COAs only
Certificates of analysis from raw material suppliers are accepted in lieu of testing each component for conformance to written specifications, without performing at least one component-specific identity test or establishing the reliability of the supplier's analyses through appropriate validation at appropriate intervals. Specifically, During the inspection conducted from September 1-5, 2025, record review revealed that your firm [illegible] lots [illegible] from [illegible] between December and June 2025. These lots were released to production based solely on the supplier's certificate of analysis. Your firm failed to [illegible] methods since establishing the business relationship. In addition, no identity or microbiological testing was performed to ensure that the [illegible] conform to established standards of quality and purity. [Illegible] used during the [illegible] stage of processing as part of [illegible]. API is intended for use in the manufacture of finished drug products.
Show observations 3 to 7
- Observation 3
Lack of cleaning validation
Failure to adequately validate written procedures for the cleaning and maintenance of equipment. Your firm did not perform cleaning validation to demonstrate the effectiveness of its cleaning procedures for the [illegible] used to package API. According to the equipment cleaning records, the [illegible] has been cleaned [illegible] times since the last batch of API was packaged on [illegible]. However, during the inspection walkthrough conducted on September 1, 2025, we observed what appeared to be residue on [illegible] on the top of the [illegible] despite the equipment being identified as clean. Therefore, by not performing cleaning validation for the [illegible], your firm fails to ensure complete removal of product residues and demonstrate that cleaning procedures are effective in preventing cross-contamination between different batches.
- Observation 4
Incomplete OOS investigations and CAPAs
Written records of investigations into unexplained discrepancies do not always include the conclusion and follow-up. Investigations initiated and performed by your Quality Unit in response to laboratory investigation reports (OOS) for active pharmaceutical ingredients, are not always comprehensive to determine all potential root causes. Additionally, Corrective and Preventive Actions (CAPA) as a result of investigations are not always comprehensive to address root causes or adequately documented to have been performed. For Example, A. Since 2021, your firm has initiated six OOS investigations for [illegible] API related to [illegible] impurities stability testing at 24, 36, and 48-month timepoints, all of which were confirmed as valid OOS results. These investigations include: OOS/21/001 dated January 11, 2021 (batch [illegible]); OOS/22/004 dated February 4, 2022 (batch [illegible]); OOS/24/021 dated August 19, 2024 (batch [illegible]); OOS/25/005 dated February 19, 2025 (batch [illegible]) and OOS/25/006 dated February 21, 2025 (batch [illegible]). Your firm has not adequately addressed this recurring deficiency despite the repeated nature of these failures. Your firm's root cause analysis attributes these OOS results to hydrolysis in the presence of water, potentially due to stability sample packaging deficiencies. The investigations revealed additional significant deficiencies in your quality systems. OOS/24/021 resulted in a product recall for batch [illegible] after your investigation identified production process issues and the discovery of a previously missed out-of-trend (OOT) result at an earlier testing timepoint. Similarly, OOS/25/005 revealed that your firm had failed to identify and investigate an OOT and OOS result at a previous testing station, indicating failures in data review and trending. Furthermore, although OOS investigations 25/005 and 25/006 have been closed and the results confirmed as valid, your firm appears to have failed to notify customers of these product quality failures as required by your quality agreements. B. From 2003 to the current inspection, your firm initiated at least four OOS investigations (OOS/23/003, dated January 9, 2023; OOS/23/004, dated January 19, 2023; OOS/25/004, dated January 24, 2025; and OOS/25/016, dated July 25, 2025) for out-of-specification assay results for API batch numbers [illegible]. Your firm's root cause analyses for these investigations consistently identified the same recurring issues: sonication deficiencies and the potential use of [illegible] glassware instead of the required [illegible] glassware. However, CAPA 290013144, dated January 19, 2023, which detailed additional procedures for sonication, proved inadequate as evidenced by the occurrence of additional OOS results in 2025, demonstrating ineffective corrective actions. Furthermore, although your firm identified the critical need for glassware during sample preparation and testing in 2023, this deficiency was not addressed until the initiation of CAPA 290019376 on July 30, 2025, a delay of over two years that allowed the same root cause to persist and contribute to repeated OOS occurrences. C. OOS Investigation 24/031, dated October 24, 2024, was initiated for KSM used in the manufacture of [illegible], with out-of-specification results of [illegible] and [illegible] versus the specification of NLT [illegible] (as is). The OOS investigation was initiated on October 24, 2024; however, the investigation was not completed until approximately April 16, 2025, nearly six months later, reportedly due to prioritization of other investigations. Your firm's identified root cause of "gross failure and variation between sample weights" lacks adequate scientific justification to explain the observed analytical results. Furthermore, by the time the investigation was conducted, the original analyst involved in the testing had departed your firm, potentially compromising the completeness and accuracy of the investi
Shortened here; the PDF has the full text.
- Observation 5
QC unit oversight and audit deficiencies
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. A. Quality unit oversight over quality control operations is deficient, including laboratory electronic systems and data review. Your firm currently maintains [illegible] networked HPLC and [illegible] networked GC instruments which utilize Empower 3. Your Quality Unit does not always review all electronic raw data generated by all HPLC/GC laboratory equipment and has not demonstrated a clear understanding of various communication errors and circumstances that can lead to aborted, interrupted, or incomplete sequences during HPLC and GC testing using Empower 3 software. During the inspection, we observed at least 28 sample set projects in Empower 3 where interruptions occurred in the form of project integrity failures. These failures were not adequately reviewed and evaluated by your Quality Unit, and no laboratory incidents were initiated by your firm at the time of these failures. The interrupted sequences were observed during the review of "Project Integrity Failed" messages, which generated "Data Incomplete" chromatographic data. During the inspection, we were able to verify the incomplete data related to API and KSM analysis. This prompted the software to convert "data incomplete" chromatograms (where no chromatograms were observed) to observable chromatograms, a conversion that your firm did not perform. During the inspection, your firm retrieved this incomplete data and performed test analysis calculations for a sample set to evaluate the interrupted sample set. Furthermore, our review found that your firm has not performed the necessary investigations and risk assessments to determine and understand the root cause for these interrupted sequences. B. Your firm's self-inspection program fails to effectively utilize quality data from ongoing monitoring activities. SOP No. MIR/07/026/08, "Self Inspection (Internal Audit)" (effective date June 13, 2024), establishes that internal audit frequency should be based on previous audit findings, including those from customer and regulatory audits. However, this procedure excludes findings from your firm's own Quality Walkthrough program conducted under SOP No. MIR/07/080/01, "Quality Walkthroughs" (effective date May 18, 2023). Our review of approximately [illegible] of Quality Walkthrough data revealed too numerous to list deficiencies, including inappropriate approved and expired raw material storage, that your firm identified but failed to address systematically. Your firm does not generate incidents for Quality Walkthrough findings, eliminating the ability to trend deficiencies and identify recurring problem areas. As a result, important quality information that could help determine when and where to conduct internal audits is not being used, creating a disconnect between your ongoing quality monitoring and formal self-inspection activities.
- Observation 6
Inadequate document control, shredding issues
Document control procedures under Quality Unit oversight are inadequate. During our walkthrough on 09/01/2025, an email document dated August 27, 2025, was discovered in your firm's outside trash bin detailing a quality walkthrough of [Areal Building] where [OD] API is manufactured. This walkthrough identified multiple deficiencies including ancillary items such as hoses and adapters in wrong boxes, dusty bags and boxes, and peeling [illegible] on the ceiling that was not properly adhered. According to your firm's SOP No. MIR/07/080/01, titled "Quality Walkthroughs" (effective date May 18, 2023), quality walkthroughs are performed by the quality assurance unit to focus on adherence to good manufacturing practices; however, your firm indicated this was an "informal quality walkthrough" that was not documented in the quality unit system. Additionally, your firm utilizes shred bins for record disposal without maintaining written procedures detailing shredding operations and which documents are permitted to be shredded. During inspection of the QA and QC office, the following records requiring retention for traceability purposes were observed in shred bins awaiting third-party destruction: Torn paper with handwritten warehouse material numbers for reconciliation. Handwritten notes summarizing [7] water sampling points. Two draft incident reports for incident #200435667 regarding an anomaly with water supply [illegible] during routine maintenance. QC analytical worksheet for determination of purity and [illegible], [illegible] caring analyst signature.
- Observation 7
Inadequate material segregation in warehouse
Manually managed materials in the warehouse and facilities are not separated during storage. This is a repeat observation from the last inspection, and your firm's corrective actions appear to have been inadequate. We reviewed Incident 200433432, dated December 2, 2024, which documented materials that were labeled as approved despite being past their retest date. Quality Walkthroughs dated [illegible] identified deficiencies including inadequate segregation of materials and rejected materials in your warehouse facilities. Additionally, there is no justification for your firm's failure to open incidents as a result of the deficiencies observed during the Quality Walkthroughs performed by QA.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Dr. Reddy's Laboratories LimitedD-U-N-S 650562841
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Dr. Reddy's Laboratories Limited (D-U-N-S 650562841) as the registrant for this site and 13 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- DR. REDDY'S LABORATORIES LIMITEDNalgonda, India · FEI 30054479657 inspections7latestMay 24, 2025VAI1 warning letter, Nov 5, 2015
- DR. REDDY'S LABORATORIES LIMITEDSrikakulam, India · FEI 30029490856 inspections6latestJun 7, 2024VAI1 warning letter, Nov 5, 2015
- DR.REDDY'S LABORATORIES LIMITEDVisakhapatnam, India · FEI 30065498359 inspections9latestMay 17, 2024VAI1 warning letter, Nov 5, 2015
- Industrias Químicas Falcón de México, S.A. de C.V. (DR. REDDY'S MEXICO)Jiutepec, Mexico · FEI 30028082973 inspections3latestAug 7, 2015NAI1 warning letter, Jun 3, 2011
- DR. REDDY'S LABORATORIES LIMITEDSrikakulam, India · FEI 30091930406 inspections6latestDec 12, 2025None on file
- DR. REDDY'S LABORATORIES LIMITEDRansthalam Mandal, Srikakulam District, India · FEI 30053368823 inspections3latestNov 14, 2025NAINone on file
- DR REDDY'S LABORATORIES LIMITEDPydibhimavaram, India · FEI 30124144621 inspection1latestJul 18, 2025VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDJinnaram Mandal, Hyderabad, India · FEI 30054480305 inspections5latestNov 19, 2024VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDMedchal-Malkajgiri District, India · FEI 30029490998 inspections8latestOct 27, 2023VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDJinnaram, India · FEI 30031844975 inspections5latestJun 16, 2023NAINone on file
- DR. REDDY'S LABORATORIES LIMITEDRanasthalam Mandal, Srikakulam, India · FEI 30111715111 inspection1latestMay 12, 2023VAINone on file
- DR. REDDY'S LABORATORIES LIMITEDSangareddy, Hyderabad, India · FEI 30028068515 inspections5latestMay 5, 2023VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002807544 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002807544. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.