Skip to content

Dr. Reddy's Laboratories Limited CTO VI

APIIC Industrial Estate, Pydibhimavaram, Ranasthalam Mandal, Srikakulam, India

FEI 3002949085DUNS 650443430

Company: Dr. Reddy's Laboratories Limited · Linked by exact D-U-N-S match (650562841) in FDA registration data

FDA has 6 inspections on file for Dr. Reddy's Laboratories Limited CTO VI in Srikakulam, India (FEI 3002949085), from 2011 to 2024. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 4 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Apr 4, 2017. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, Dr. Reddy's Laboratories Limited (D-U-N-S 650562841), has registered 13 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
6, 2011–2024
2 OAI · 2 VAI · 2 NAI
Inspections with 483 observations shown
3 of 6
Form 483s posted by FDA
↗
3 posted
Requested under FOIA
1 request, latest Sep 9, 2024
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Unvalidated/ unverified analytical methods

      Analytical methods were not validated or verified under the actual conditions of use. These methods are used for testing of final Active Pharmaceutical Ingredients (API) before releasing the APIs for the manufacturing of drug products. Specifically, A. The following test methods, including in-house and compendial test methods, were not validated or verified appropriately for the commercial APIs. These APIs have active US Drug Master Files (DMF) and batches were distributed to customers and are currently in the market. API IUSDMF# Test Description Specification# (b)(4) Specific Optical Rotation S-08-ADG-01/08 Identification by IR SP-CTO06-003570 Identification by IR SP-CTO06-002687 Specific Optical Rotation SP-CTO06-003013 Specific Optical Rotation SP-CTO06-002538 Specific Optical Rotation at [illegible] SP-CTO06-002617 Identification by IR S-08-IG/06 Identification By Mass Spectrometry Identification by IR SP-CTO06-002685 Specific Optical Rotation Water Content by KF SP-CTO06-002756 Identification by IR Water Content by KF SP-CTO06-003026 Identification by IR SP-CTO06-003561 Identification by IR SP-CTO06-002658 Identification by IR SP-CTO06-002663 XRD (b)(ii) Identification test for SP-CTO06-002807 Identification by IR SP-CTO06-002676 Identification by IR SP-CTO06-003929 Identification by IR SP-CTO06-002968 Identification by IR SP-CTO06-003459 Water Content by KF Identification by IR SP-CTO06-002588 Water Content by KF Identification by IR Water Content by KF SP-CTO06-002677 Optical Rotation by Polarimeter XRD SP-CTO06-002894 Water Content by Coulometer SP-CTO06-004059 Identification by IR SP-CTO06-003243 Identification by IR SP-CTO06-003495 Specific Optical Rotation SP-CTO06-003679 Identification for SP-CTO06-002622 You received a customer complaint #200428799 for the API (b)(4), which identified that the API you supplied (Batch# [illegible]) showed OOS for Water Content test, with a result of (b)(4) against specification limit NMT (b)(4)% which had been released with non-validated test method. B. The analytical method used to quantitate residual (b)(4) in (b)(4) API was not adequately validated prior to the release of API batches. From 2020 to 2023, an unknown peak characterized as (b)(4) was identified during the GC residual solvent analysis release testing in approximately (b)(4) batches of API. Once the characterization of the unknown peak as (b)(4) was completed, an internal control limit of not more than (b)(4) ppm was determined and established for this impurity. Of the (b)(4) batches of (b)(4) manufactured, approximately (b)(4) batches were released and shipped, including batches (b)(4) and (b)(4) which were intended for use in US marketed products, based on results obtained for the (b)(4) content following a GC developed method. However, analytical method validation was not performed for this GC method. Subsequently, a [illegible] chromatography method was developed and validated on 01 May 2022 for quantitation of (b)(4). However, the (b)(4) batches shipped were not retested using this validated procedure to ensure the content was within the internal specification, including batches (b)(4) and (b)(4). Furthermore, batches (b)(4) and (b)(4) were released on 26 Jun 2021; however, communication about the detection of (b)(4) and the subsequent control limit was not communicated to the customer until November 2022.

    2. Observation 2

      Manufacturing process not validated

      There is a failure to ensure that manufacturing processes are maintained in a validated state. Specifically, From May 2022 to January 2024, 17 out-of-specification results have been obtained for (b)(4) API from in-process checks or during final release testing due to elevated levels of (b)(4) not meeting the pre-defined specification limit. These investigations led to the reprocessing of all 17 batches of (b)(4) including approximately [illegible] batches intended for use in US marketed products. Various root causes have been hypothesized and addressed through corrective actions, including but not limited to, correction of the [illegible], additional controls of humidity during the stages of [illegible], and controlling the length of time in which the material can be held before further processing during various stages. 1) Incident 200429644 was initiated on 20 Apr 2024 due to an out of specification result obtained for (b)(4) of (b)(4) ppm (specification not more than (b)(4) ppm) during in-process sampling of Batch (b)(4). The root cause of the investigation was identified as smaller API particles being generated during the (b)(4) phase of the manufacturing process. 2) Out-of-specification 310026212 was initiated on 09 Apr 2024 due to an out-of-specification result obtained for (b)(4) of (b)(4) ppm (specification not more than (b)(4) ppm) during release testing of Batch (b)(4). The root cause was determined to be improper sampling during in-process sampling and testing since there is a chance of non-material uniformity by inadequate mixing prior to sampling. Although corrective actions have been identified and have been or are being implemented into the (b)(4) API Master Batch Record, there has been no holistic review or assessment performed to ensure that the process is under adequate control and the process has been maintained in a validated state. In addition, the recent investigations conducted indicate a lack of process controls during (b)(4) operations as well as potential non-homogeneity of the material held during (b)(4) operations.

    Show observations 3 to 4
    1. Observation 3

      Inadequate OOS investigations and CAPA

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, A. The attributed root causes for the Out of Specification (OOS) investigations are not adequately supported with scientific evidence. For example, 1) OOS investigation 310024[illegible]- An investigation was initiated on [illegible], 2023, when an annual stability batch of (b)(4) (Batch# [illegible], DMF# [illegible]) gave an OOS result for Related Substances by HPLC (Method-1) at 12M on long term stability conditions (25±2°C). The result was (b)(4)% against a specification of NMT (b)(4)%. The investigation concluded that sample pouch might have exposure to light/air during sampling of individual stability interval station and resulting in increase of the (b)(4). However, this root cause was not adequately justified with scientific evidence. 2) API (batch# (b)(4)) gave (b)(4) content by potentiometry a result of (b)(4) (Specification limit: [illegible]). Attributed root cause: A. bubbles in the dispensing tube. However, this root cause was not adequately justified with scientific evidence. 3) OOS# 310023657/31002365[illegible]/310023685/310023686/31002[illegible]/310021705 - (b)(4) six batches (b)(4) (b)(4) (b)(4) (b)(4) (b)(4) (b)(4) had residual solvents by GC in content range of (b)(4) ppm to (b)(4) ppm against specification limit of NMT (b)(4) ppm. Attributed root cause: cleaning of sampling area with (b)(4). However, this root cause was not adequately justified with scientific evidence. 4) OOS# 310026212, (b)(4) API (batch# (b)(4)) - residual solvents by GC (b)(4) ppm against a specification limit of NMT (b)(4) ppm. Attributed root cause: in-process sampling may be an issue. However, this root cause was not adequately justified with scientific evidence. B. Investigations do not always implement adequate corrective and preventive actions to address the identified root causes and prevent recurrence. For example, 1) During the GC residual solvents release testing performed for (b)(4) API from January 2020 to June 2023, an unknown peak identified as (b)(4) was observed in approximately (b)(4) batches. The batches were subsequently investigated, and the root cause of the unknown peak was attributed to the key starting material, as the raw material in its synthesis. The corrective action identified for controlling the presence of (b)(4) in the final API was to maintain a higher volume of retained (b)(4) during the (b)(4) operation as the impurity (b)(4) during the manufacturing process. The corrective action to maintain the volume between (b)(4) to (b)(4) was implemented in June 2020; however, this volume value was changed back to the original control in October 2020. Since October 2020, 60 instances of the unknown peak present were obtained with the same root cause, however no additional corrective actions were implemented to adequately control the manufacturing process as identified originally in June 2020 until September 2023. 2) Incident 200414087 was initiated on 22 Apr 2023 due to residual (b)(4) solvent content in (b)(4) result exceeding the cleaning specification of not more than (b)(4) ppm during cleaning validation of (b)(4). The root cause of the investigation was contamination in the [illegible] container used for (b)(4) rinsing which (b)(4) is also used. It was concluded that no impact to any other batches, and corrective actions, including incorporating (b)(4) cleaning procedures between solvent changes, were identified. Additionally, Incident 200426113 was initiated on 23 Jan 2024 with a similar root cause for inadequate cleaning of (b)(4) containers and similar corrective actions identified. However, there was no assessment performed of other cleaning records where there is lack of instruction in cleaning and use of the [illegible] containers nor were preventive actions identified to c

      Shortened here; the PDF has the full text.

    2. Observation 4

      Materials released without complete QA release

      There is a failure to ensure that materials are not released before the satisfactory completion of evaluation by the quality unit. Specifically, Batches of (b)(4) API intended for use in US marketed products were released by the quality unit without completion of all applicable release tests prior to distribution. (b)(4) API is tested following specifications SP-CTO06-002815 and CS/IO12/04 and requires additional testing for particle size distribution. Change controls CC1000087928 and CC1000098929 were initiated on 14 Jul 2022 for batch (b)(4) and on 03 Dec 2022 for batches (b)(4), (b)(4), and (b)(4), respectively, to release the batches without completion of the particle size distribution testing, as required per the specification. The Certificates of Analysis were issued with a note indicating that particle size testing was not performed with reference to the respective change controls. Change controls CC1000087928 and CC1000098929 were closed and approved by the quality unit on 19 Jul 2022 and 28 Dec 2022, respectively.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate process validation

      OBSERVATION 1 Process Validation is not performed adequately for manufactured products Specifically, your process validation for the (b)(4) Out of Specification (OOS) 2019 for manufacturing of commercial batches. Solvents (RS) by Gas Chromatography (GC) specification limit of NMT (b)(4) ppm. (b)(4) OOSs were rejected and (b)(4) for shipment. (b)(4) batches are awaiting to be Your firm reported a full-scale investigation summary report November 30, 2019 to investigate the failure batches (b)(4). The OOS evaluated an out of Chromatography for batch #(b)(4) with an issue with the (b)(4) reported. Additionally, "no impact on the further batches"

    2. Observation 2

      Inadequate OOS investigations

      OBSERVATION 2 Investigations are inadequate in that they do not evaluate all potential root causes. Specifically, A. Investigations for the following Out of Specifications (OOS) and Incidents were not performed adequately. For example, 1. For OOS # 310018104 and Incident # (b)(4) with report date December (b)(4) (b)(4) process (b)(4) cause is determined to be by inadvertent human error. The batch was then moved for further production, however, during release testing 310018104 was observed. The batch failed for Solubility testing and failed for residual solvent (b)(4) (ppm) on December 23, 2019. During the final release investigation, the most probable cause was identified that the original test results for the in-process run (b)(4) which was initially identified to be '(b)(4)' results were discarded with documented justification. 2. OOS # 310017867 with report date October (b)(4). An OOS result was reported for (b)(4) content (b)(4) (b)(4) as (b)(4). The OOS was for (b)(4) specification limit of (b)(4) ppm. Your firm only performed a laboratory investigation. The documented most probable root cause was determined (b)(4) weighing balance or the micropipette during laboratory analysis without (b)(4) manufacturing area. 3. OOS # 310016984 with report date (b)(4). An OOS result was (b)(4) (b)(4) % . According to specification NLT: (b)(4) % and NMT: (b)(4) %. The re-analysis was conducted on April (b)(4) (b)(4) specifications '(b)(4) (b)(4) %,'(b)(4)-T provided for the failing reanalysis result (b)(4) from the already used injected vials. (b)(4) United States market. B. During the inspection we observed that (b)(4) batch #(b)(4) for unknown peaks your firm s SOP SOP-GLOB-QC-0018, investigations for residual solvents states (b)(4) determined to have no investigation. These unknown peaks appear to be isomers of (b)(4). C. Risk Assessments titled 'Assessment of (b)(4) CTO-VI Dr. Reddy's Laboratories Limited' with (b)(4) to assess the potential presence of (b)(4) (b)(4) and other (b)(4) impurity in the Key Starting Material (KSM) was (b)(4). Additionally our firm doesn't test for (b)(4). (b)(4) shipped multiple batches of (b)(4). (b)(4) were not notified.

    Show observations 3 to 4
    1. Observation 3

      Inadequate cleaning validation

      OBSERVATION 3 Your firm's cleaning processes for equipment have not been adequately established and validated. Specifically, your firm's Quality Unit failed A. According to section 5.13.1 of your firm's Standard Operating Procedure SOP-GLOB-QA-0048, Cleaning Validation Program for Drug Substance states, "... process involves successful completion". However, your cleaning validation report, titled 'Report on equipment cleaning validation during (b)(4) (b)(4)' date February (b)(4), 2017 was performed with (b)(4). According to the cleaning validation report section VIII states, production plan and no visibility of future plan for (b)(4) facility, the cleaning validation study (b)(4) execution of (b)(4). A new cleaning validation study shall (b)(4) approach of cleaning validation, if warranted. That the firm did not manufacture (b)(4) on (b)(4) 17, 2017. He further stated the '(b)(4) batch' September 10, 2018. The firm manufactured (b)(4) in 2019 and (b)(4) validation (b)(4) runs as required by B. During our review of the surface area of (b)(4) validation, we asked for the raw data for the surface calculations for each equipment. According to the Team Member Process (b)(4) raw data for the surface area calculation for each manufacturing equipment. No raw data, there is no evidence that swab samples were actually analyzed. He further stated that they do not have raw data calculations for all the cleaning validations. C. According to the Team Member Quality Assurance the Quality Unit's point locations for swab samples of product contact surfaces during cleaning validation were based on "experience" and not scientific justification. D. During our review it was observed that (b)(4) (b)(4) observed in the analysis of (b)(4) (b)(4). In addition, the firm has recorded (b)(4) such as (b)(4) United States.

    2. Observation 4

      No trend analysis of API data

      OBSERVATION 4 Trend Analysis of manufactured APIs Specifically, no trend analysis was conducted for manufactured APIs. Your firm has approximately nineteen (19) (b)(4) during our review of the residual solvent from (b)(4).

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete calibration/UV lamp monitoring

      Complete records are not always maintained for periodic calibration of laboratory instruments, apparatus, gauges, and recording devices. [For all High Performance Liquid Chromatography systems (HPLC), the firm failed to monitor the lamp hours of their UV detectors. In addition, monitoring of the QC laboratory’s HPLC units does not include a periodic check of the hours of the UV-Vis lamps after 2000 hours of operation as recommended by the manufacturer. For example, six (6) of the HPLC units, QC-170, QC-169, QC-024, QC-026, QC-122 and QC-021, showed operational hours of 13,003 hours, 11,132 hours, 5,106 hours, 3,475 hours, 3,198 hours, and 2,371 hours respectively without the lamps being replaced or being reset to zero after changing of the lamp.

    2. Observation 2

      Incomplete laboratory chromatogram records

      Laboratory records do not include a complete record of all data secured in the course of each test, including all chromatograms from laboratory instrumentation, properly identified to show the specific components of the drug substance tested. Specifically, laboratory records do not always contain the HPLC standard and sample chromatograms. For example, the laboratory records for USP Batch [illegible] manufactured 2/25/2017, [illegible] manufactured 2/23/2017, [illegible] manufactured 2/22/2017, did not include the HPLC standard and sample chromatograms for Assay and Related Substances instead only results summary reports are attached. The chromatographic data was limited to calculated results for last 3 months.

  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Sep 9, 2024. It asked for a Form 483.

  • Inspection ending Jun 7, 2024VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Sep 9, 2024FDA-FOIA-2024-8000Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002949085, one row per refused product line.

1 refusal on 2020-08-25 · charged UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2020-08-25

    MISCELLANEOUS PATENT MEDICINES, ETC.66VDA99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast ImportsSCS-1528256-1/11/1

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, packing, analysis
Registration runs through
Dec 31, 2027
Registrant
Dr. Reddy's Laboratories LimitedD-U-N-S 650562841

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Dr. Reddy's Laboratories Limited (D-U-N-S 650562841) as the registrant for this site and 13 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3002949085 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3002949085. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.