FDA issued this Form 483 to Dr. Reddy's Laboratories Unit 6 in Srikakulam, India (FEI 3002949085) at the end of a drug inspection that ended April 4, 2017. It lists 2 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Apr 25, 2017. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Apr 4, 2017
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Apr 25, 2017
- 21 days after the inspection
The 2 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Incomplete calibration/UV lamp monitoring
Complete records are not always maintained for periodic calibration of laboratory instruments, apparatus, gauges, and recording devices. [For all High Performance Liquid Chromatography systems (HPLC), the firm failed to monitor the lamp hours of their UV detectors. In addition, monitoring of the QC laboratory’s HPLC units does not include a periodic check of the hours of the UV-Vis lamps after 2000 hours of operation as recommended by the manufacturer. For example, six (6) of the HPLC units, QC-170, QC-169, QC-024, QC-026, QC-122 and QC-021, showed operational hours of 13,003 hours, 11,132 hours, 5,106 hours, 3,475 hours, 3,198 hours, and 2,371 hours respectively without the lamps being replaced or being reset to zero after changing of the lamp.
- 2
Incomplete laboratory chromatogram records
Laboratory records do not include a complete record of all data secured in the course of each test, including all chromatograms from laboratory instrumentation, properly identified to show the specific components of the drug substance tested. Specifically, laboratory records do not always contain the HPLC standard and sample chromatograms. For example, the laboratory records for USP Batch [illegible] manufactured 2/25/2017, [illegible] manufactured 2/23/2017, [illegible] manufactured 2/22/2017, did not include the HPLC standard and sample chromatograms for Assay and Related Substances instead only results summary reports are attached. The chromatographic data was limited to calculated results for last 3 months.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3002949085, newest first.
- Form 483, June 2024Inspection ended Jun 7, 2024 · Posted Jun 20, 2024VAI
- Form 483, January 2020Inspection ended Jan 28, 2020 · Posted Feb 5, 2020VAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.