21 CFR 211.68: Automatic, mechanical, and electronic equipment

FDA's inspection data lists 1,662 Form 483 citations of 21 CFR 211.68 at 1,239 facilities, from October 2008 to September 17, 2026. 29 warning letters state a violation of it.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
1,662
At 1,520 inspections
Facilities cited
1,239
Distinct FEIs
Most recent citation
Sep 17, 2026
Hain-Celestial Canada, ULC
Warning letters
29
State a violation of it

The regulation

The current text of 21 CFR 211.68 from the Electronic Code of Federal Regulations.

§ 211.68 Automatic, mechanical, and electronic equipment.

(a) Automatic, mechanical, or electronic equipment or other types of equipment, including computers, or related systems that will perform a function satisfactorily, may be used in the manufacture, processing, packing, and holding of a drug product. If such equipment is so used, it shall be routinely calibrated, inspected, or checked according to a written program designed to assure proper performance. Written records of those calibration checks and inspections shall be maintained.

(b) Appropriate controls shall be exercised over computer or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Input to and output from the computer or related system of formulas or other records or data shall be checked for accuracy. The degree and frequency of input/output verification shall be based on the complexity and reliability of the computer or related system. A backup file of data entered into the computer or related system shall be maintained except where certain data, such as calculations performed in connection with laboratory analysis, are eliminated by computerization or other automated processes. In such instances a written record of the program shall be maintained along with appropriate validation data. Hard copy or alternative systems, such as duplicates, tapes, or microfilm, designed to assure that backup data are exact and complete and that it is secure from alteration, inadvertent erasures, or loss shall be maintained.

(c) Such automated equipment used for performance of operations addressed by §§ 211.101(c) or (d), 211.103, 211.182, or 211.188(b)(11) can satisfy the requirements included in those sections relating to the performance of an operation by one person and checking by another person if such equipment is used in conformity with this section, and one person checks that the equipment properly performed the operation.

21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart DRead on eCFR

Citations by year

Form 483 citations of 21 CFR 211.68 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 137 in 2017

Form 483 citations of 21 CFR 211.68 by inspection year
YearForm 483 citations
200810
200968
201098
201196
201275
201368
201485
201593
2016104
2017137
2018117
2019126
202041
202174
202298
202387
202488
2025135
202662

How FDA words this citation

FDA's short descriptions and citation text on these 1,662 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Calibration/Inspection/Checking not done702 citations
  • Computer control of master formula records579 citations
  • input/output verification120 citations
  • Written calibration / inspection records not kept119 citations
  • Backup data not assured as exact and complete59 citations
Show 2 more
  • Backup file not maintained51 citations
  • Written record not kept of program and validation data32 citations

Citation text

  • “Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.”538 citations
  • “Routine calibration of equipment is not performed according to a written program designed to assure proper performance.”74 citations
  • “Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.”64 citations
  • “Routine calibration, inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.”64 citations
Show 2 more
  • “Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.”58 citations
  • “Records of the calibration checks of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.”47 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 211.68, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Show 4 more

What the observations say

Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.68 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 34 observations tie this way. The highlighted sentence is the matched wording.

  • RC Outsourcing LLC2026-09-03 · Observation 5

    Routine calibration, inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance. Specifically, Your firm has not performed temperature mapping under the worst-case conditions for your critical equipment during equipment qualification. For example, your firm operates incubators (b)(4); and (b)(4) refrigerators (b)(4), all of which are used for …

    This observation opens with FDA's standard wording for 21 CFR 211.68(a).

  • TOYO Pharmaceutical Co., Ltd.2026-06-12 · Observation 2

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Your firm does not have unique usernames and passwords for each operator using electronic systems in production. Your firm only has one login password for each of the following production equipment using electronic systems for setting …

    This observation opens with FDA's standard wording for 21 CFR 211.68(b).

  • PQ Pharmacy LLC2026-06-01 · Observation 4

    Records of the inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained. Specifically, A) During post-use (b)(4) of the sterilizing (b)(4) used for prednisolone sodium phosphate 1% / moxifloxacin HCl 0.5% / bromfenac 0.09% PF, Lot PMB121525CH BUD 12/15/2026, two (2) consecutive tests resulted in the error message "Error: (b)(4) Not Obtainable"; neither were recorded in the batch …

    This observation opens with FDA's standard wording for 21 CFR 211.68(a).

Show 2 more
  • Shilpa Medicare Limited2026-05-29 · Observation 5

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, Per your Production Manager (b) (6) your firm does not review data, audit trails and alarm reports generated by the HMIs (GT-2708) and SCADA of your non-dedicated equipment ID #PR-E016) (b) (4) and (ID #MB-E030) utilized in the Micro …

    This observation opens with FDA's standard wording for 21 CFR 211.68(b).

  • Zydus Lifesciences Limited2026-05-05 · Observation 7

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Specifically, your firm does not have procedures in place for electronic data review prior to batch release. The procedure titled “Review of Electronic Audit Trails” 0310-SOP-QA-00075, section 6.11.6, indicates that QA is permitted to perform batch …

    This observation opens with FDA's standard wording for 21 CFR 211.68(b).

Warning letters stating a violation of 21 CFR 211.68

29 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.

“Your firm failed to exercise appropriate controls over computer or related systems to assure that only authorized personnel institute changes in master production and control records, or other records (21 CFR 211.68(b)).”

Each letter below states the violation in these words.

Often cited at the same inspection

Of the 1,520 inspections where FDA cited 21 CFR 211.68, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 211.68

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

Topics that count this section:Data integrity

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.68; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.