Zydus Lifesciences Limited
Plot Survey 23,25/P,37,40/P,42 To 47, Opp. Ramdev Masala, Village - Changodar, Sarkhej-Bavla N.H. 8a, Tal Sanand, Ahmedabad, India
FEI 3012977526DUNS 677604722
FDA has 2 inspections on file for Zydus Lifesciences Limited in Ahmedabad, India (FEI 3012977526), from 2023 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant is Zydus Lifesciences Limited (D-U-N-S 677604722).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2023–2026
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the sterilization process.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Show 2 more citations
In-process materials characteristics testing
In-process materials are not tested for quality and approved or rejected by the quality control unit during the production process.
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that floors and walls are not smooth and/or hard surfaces that are easily cleanable.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.192Production record review1 of 1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Zydus Lifesciences LimitedD-U-N-S 677604722
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Zydus Lifesciences Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Zydus Lifesciences LimitedFEI 3013712903India
Last inspected 2025-09-05
Zydus Lifesciences LimitedFEI 3005430968India
Last inspected 2025-08-13
Zydus Lifesciences LimitedFEI 3007621329Matoda, India
Last inspected 2025-06-17VAI
Zydus Lifesciences LimitedFEI 3002806475Dabhasa, Vadodara, India
Last inspected 2025-04-25VAI
Zydus Lifesciences LimitedFEI 3003696998Ankleshwar, India
Last inspected 2025-03-14NAI
Zydus Lifesciences LimitedFEI 3006026405Ahmedabad, India
Last inspected 2025-02-14NAI
Zydus Lifesciences LimitedFEI 3006809732Kalyan, India
Last inspected 2025-02-14NAI
Zydus Lifesciences LimitedFEI 3008957483Ahmedabad, India
Last inspected 2024-07-19VAI
Zydus Lifesciences LimitedFEI 3007938603Matoda, India
Last inspected 2023-03-24VAI
Zydus Lifesciences LimitedFEI 3002984011Ahmedabad, India
Last inspected 2022-08-05VAI
Not every site is listed: these are the most recently inspected sites found under this name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012977526 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012977526. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.