Zydus Lifesciences Limited
Sarkhej-Bavla National Highway No 8a, Survey No 417; National Highway 8a; 419-420 Moraiya Taluka, Ahmedabad, India
FEI 3002984011DUNS 918596198
Company: Zydus Lifesciences Limited · Linked by exact D-U-N-S match (918596198) in FDA registration data
FDA has 10 inspections on file for Zydus Lifesciences Limited in Ahmedabad, India (FEI 3002984011), from 2009 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the six FOIA requests for this site have asked FDA for this inspection's 483, and two more for the 483 from a later inspection, ending Oct 13, 2026, that FDA's Data Dashboard doesn't list yet.
The most recent OAI inspection ended on May 3, 2019. FDA has issued 3 warning letters under this FEI, the latest on (CDER). 4 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.192 and 21 CFR 211.100(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Zydus Lifesciences Limited (D-U-N-S 918596198), has registered 2 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 10, 2009–2022
- 3 OAI · 3 VAI · 4 NAI
- Inspections with 483 observations shown
- 3 of 10
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 6 requests, latest FY2023
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the identification, handling and sampling of components and drug product containers.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 14 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Air filtration system lacking in production area
The production area air supply lacks an appropriate air filtration system.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Backup file not maintained
Failure to maintain a backup file of data entered into the computer or related system.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Show 9 more citations
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Complete instructions, procedures, specifications et. al.
Master production and control records lack complete manufacturing and control instructions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
In-process materials specifications
In-process specifications are not determined by the application of suitable statistical procedures where appropriate.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written record of complaint to include findings, follow-up
Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Mix-up
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning an incident that caused a drug product or its labeling to be mistaken for another article.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Six requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Oct 13, 2026
2 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Oct 30, 2026. FDAgent holds no copy that FDA posted.
- Oct 26, 2026FDA-FOIA-2026-10339Form 483Open
- Oct 14, 2026FDA-FOIA-2026-9980Form 483Records released
Inspection ending Aug 5, 2022VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2023-989Form 483Closed
- FY2023FDA-FOIA-2022-8456Form 483Closed
Inspection date not given
2 requests. FDA released records in answer to a request for its Form 483 on Oct 30, 2026. FDAgent holds no copy that FDA posted.
- FY2023FDA-FOIA-2022-7609Form 483Closed
- Oct 14, 2026FDA-FOIA-2026-10014Form 483Records released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 10 inspections, with how many of them cited each.
- 21 CFR 211.192Production record review3 of 3
- 21 CFR 211.100Written procedures; deviations2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.42Design and construction features1 of 3
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.80General requirements1 of 3
Show all 15
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.111Time limitations on production1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.186Master production and control records1 of 3
- 21 CFR 211.198Complaint files1 of 3
- 21 CFR 314.81Other postmarketing reports1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002984011, one row per refused product line.
4 refusals from 2020-03-11 to 2026-10-21 · charged UNAPPROVED on 4, NOT LISTED on 1 · no FDA sample analysis
FDA firm profile- 2026-10-21
ANTI-DIABETIC N.E.C.61PCA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-2027330-5/60003/1
- 2026-09-08
ANTI-DIABETIC N.E.C.61PDA99
NOT LISTED 502(o), 801(a)(3); MISBRANDING
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports1FX-1476886-6/10002/1
- 2022-11-17
ANASTROZOLE (HORMONE)64RCE17
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-1876875-2/11/1
- 2020-03-11
CHORIONIC GONADOTROPIN (GONAD-STIMULATING PRINCIPLE)64MCY04
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-9125691-8/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Zydus Lifesciences LimitedD-U-N-S 918596198
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Zydus Lifesciences Limited (D-U-N-S 918596198) as the registrant for this site and the 2 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Zydus Lifesciences LimitedAhmedabad, India · FEI 30060264054 inspections4latestFeb 14, 2025NAINone on file
- Zydus Lifesciences LimitedMatoda, India · FEI 30079386035 inspections5latestMar 24, 2023VAINone on file
Other FEIs recorded as Zydus Lifesciences Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Zydus Lifesciences LimitedFEI 3012977526Ahmedabad, India
Last inspected 2026-05-05VAI
Zydus Lifesciences LimitedFEI 3013712903India
Last inspected 2025-09-05
Zydus Lifesciences LimitedFEI 3005430968India
Last inspected 2025-08-13
Zydus Lifesciences LimitedFEI 3007621329Matoda, India
Last inspected 2025-06-17VAI
Zydus Lifesciences LimitedFEI 3002806475Dabhasa, Vadodara, India
Last inspected 2025-04-25VAI
Zydus Lifesciences LimitedFEI 3003696998Ankleshwar, India
Last inspected 2025-03-14NAI
Zydus Lifesciences LimitedFEI 3006809732Kalyan, India
Last inspected 2025-02-14NAI
Zydus Lifesciences LimitedFEI 3008957483Ahmedabad, India
Last inspected 2024-07-19VAI
Zydus Lifesciences LimitedFEI 3007834858Moraiya, India
Last inspected 2020-03-04NAI
Zydus Lifesciences LimitedFEI 3006595385Ahmedabad, India
Last inspected 2014-12-06OAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002984011 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002984011. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.