FEI 3013712903DUNS 873671928

FDA has 3 inspections on file for Zydus Lifesciences Limited in India (FEI 3013712903), from 2022 to 2025. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent has not read its observations yet; the PDF has them. One of the six FOIA requests for this site has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Apr 23, 2024. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing and analysis, through Dec 31, 2027. Its registrant is Zydus Lifesciences Limited (D-U-N-S 873671928).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
3, 2022–2025
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 3
1 PDF not read yet · 1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
4 posted
Requested under FOIA
6 requests, latest Feb 10, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 10 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Following/documenting laboratory controls

      Established sampling plans and test procedures are not followed.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    5. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    Show 5 more citations
    1. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    2. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    3. Cleaning SOPs/instructions

      Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

    4. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    5. Training , Education , Experience overall

      Employees engaged in the manufacture of a drug product lack the training required to perform their assigned functions.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Stability testing delays

      OBSERVATION 1 The written stability testing program is not followed. Specifically, the stability program is not followed to complete the testing within predefined time frame. The Quality Unit failed to test about 250 stability samples within [illegible] days as required under, "SOP for Stability Management (Document# 0317-SOP-QC-00132, Effective Date: 7/23/2021)." Examples of stability samples that were delayed testing include: Product/Material Batch No. Storage Conditions Stability Timepoint Total # of Days Delayed 7 f6)(4) I 25°C/60%RH 275 Day(s) 122 INJECTION USP1[b)] mg/vial {! 7 b)(.f) I 25°C/60%RH 275 Day(s) 122 INJECTION USP1[b)] f6)(4)7 mg/vial {! 7 <6f<-l) I 40°C/75% RH 183 Day(s) 120 f6)(4) INJECTION USP1[b)] mg/vial {! ----p,>(<) Ju 30°C/65% RH 92 Day(s) 109 ~b)(4) INJECTION USP~~' mg/vial I 30°C/65% RH 92 Day(s) 110 7"rc<j Ju INJECTION USP~:> mg/vial f6)(4) I 30°C/65% RH 92 Day(s) 109 ----p,>(<) Ju f6)(4)7 INJECTION USP~:> mg/vial 7 6f(.f) I 25°C/60% RH 183 Day(s) 120 ffif(,1'7 INJECTION USP1[b)] mg/vial {! 7 b)(.f) 40°C/75% RH 183 Day(s) 126 I INJECTION USP1[b)] mg/vial f6)(4)7 {! 7 6f(.f) 25°C/60% RH 183 Day(s) 126 I INJECTION USP1[b)] mg/vial ffif(,1'7 {! 7 b)(.f) I 25°C/60% RH 366 Day(s) 125 f6)(4)7 INJECTION USP1[b)] ffif(,1'7 {!} mg/vial ?H-l) 5°C± 3°C 275 Day(s) 68 INJECTION1[b)] mcg/mL, ~ mL f6)(4)7 {! 7 <6f<-l) 5°C± 3°C 275 Day(s) 68 fb)(4) INJECTION1[b)] mcg/mL, ~ mL {! 7 b)(.f) IE 5°C± 3°C 275 Day(s) 59 INJECTION1[b)] ~b)(4) mcg/mL, mL I {! 7 <6f<-l) 5°C± 3°C 275 Day(s) 59 INJECTION1[b)] mcg/mL, ~ mL fb)(4) {! I 7 b)(.f) 5°C± 3°C 275 Day(s) 59 4 f6)(4)7 INJECTION b)<>mcg/mL,~ mL 7 6f(.f) 5°C± 3°C 275 Day(s) 59 4 Jlif(,1'7 INJECTION b)<>mcg/mL,~mL 5°C± 3°C 275 Day(s) 54 7")(<) JI f6)(4)7 INJECTION~:> mcg/mL, mL 5°C± 3°C 275 Day(s) 54 -isrc<j JI INJECTION1[b)] mcg/mL < mL ffif(,1'7 {! , 7 b)(.f) 5°C± 3°C 275 Day(s) 34 f6)(4)7 INJECTION1[b)] mcg/mL, ~ mL {! - ~fif(.f) 5°C± 3°C 275 Day(s) 34 INJECTION1[b)] ffif(,1'7 {!} mcg/mL, ~ mL 7n-f> I Injection 25°C/60% RH 183 Day(s) 91 mL f6)(4)7 rn mg/mL, The site primarily manufactures injectable drug products for the US market. Significant number of f6>l.il)l batches (representative of the commercial products in the market) were delayed stability testing as well.

    2. Observation 2

      Annual product quality reviews missed

      OBSERVATION 2 Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected. Specifically, written procedure pertaining to the Annual Product Quality Review of the commercial drug products manufactured at the site is not followed. The firm performs Annual Product Quality Reviews (APQR) as per SOP, "Annual Product Quality Review", Document # 0317-SOP-QA-00076, Effective Date: 7/23/2021). Section 6.1.4 of this SOP states, "APQR shall be approved within [illegible] days of scheduled time period." The scheduled time period to complete the review is the [illegible] approval date. The Quality Unit failed to complete the APQRs for the following products within due period: Actual Sr. Intended Total number Product Name completion No. completion date of days delayed date f6>-(4) IInj. 1 12/19/2020 2/24/2021 67 USP mg/ml, ml 6)14) F In j. 2 USP b) mg/ml,~:> ml ~ )14) ~ In j. 3 6/8/2021 7/24/2021 46 USP, b) mg/mL,~:> mL b)(.J) I1nj.:~J 4 mg/mL, ,l mL 6f(4) IInj. ~r~ 5 mg/mL, ,CmL 12/6/2020 12/26/2020 20 b)(.J) I1nj. 6 ~Jmg/mL,,l mL 6f(4) I1nj. 7 ~Jmg/mL, ,( mL

    Show observation 3
    1. Observation 3

      Facility repairs causing contamination risk

      OBSERVATION 3 Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, the Compounding Room used in the manufacturing of sterile injectable drugs is not maintained in a good state of repair to prevent contamination. On 3/2/2022, significant deficiencies were observed during the inspection of Compounding Room (ID: ffiH..f>7) associated with filling line. For example: A. A scratch (about one inch) with missing paint was observed on the ceiling located on top of the compounding vessel (ID: M055). The missing paint was observed on top of the HEPA filter (ID: ME044) installed above the Compounding Vessel. This is an open processing area where the API and excipients are r[f<-l>7 into the compounding vessel fbH-l>7 . B. This Compounding Room (ID: l(b)C>l) has two pipes (for incoming and outgoing supply of b)C> f H~) I) connected to the Compounding Vessel (ID: M055). The sealant applied around the pipes (when they go through the ceiling) was not smooth; hence making it hard to clean surface. Filling line ~ is a high volume machine used to manufacture products with bigger batch size. Currently, this line is used to manufacture ffiJ(-lf7 commercial drug products for the US market.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on Feb 10, 2026.

  • Inspection ending Sep 5, 2025Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Feb 10, 2026FDA-FOIA-2026-1432Form 483Records released
  • Inspection ending Apr 23, 2024OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 1, 2024FDA-FOIA-2024-3899Form 483· 1 of 2 sitesClosed
    2. Apr 24, 2024FDA-FOIA-2024-3788Form 483Closed
  • Inspection ending Mar 10, 2022VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Apr 27, 2022FDA-FOIA-2022-3027Form 483Closed
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its EIR on Jul 25, 2025. FDAgent holds no copy that FDA posted.

    1. Mar 10, 2025FDA-FOIA-2025-2222EIRRecords released
    2. Mar 3, 2025FDA-FOIA-2025-1833Form 483 + EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
Zydus Lifesciences LimitedD-U-N-S 873671928

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other FEIs recorded as Zydus Lifesciences Limited

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Not every site is listed: these are the most recently inspected sites found under this name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3013712903 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3013712903. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.