Zydus Lifesciences Limited
Plot 1a, 8a Pharmez Special Economic Zone; Sarkhej-Bavla N H No, Matoda, India
FEI 3007621329DUNS 650348852
FDA has 9 inspections on file for Zydus Lifesciences Limited in Matoda, India (FEI 3007621329), from 2012 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. One of the four FOIA requests for this site has asked FDA for this inspection's 483, and two more for the 483 from a later inspection, ending Nov 13, 2025, that FDA's Data Dashboard doesn't list yet.
The most recent OAI inspection ended on Mar 27, 2024. No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant is Zydus Lifesciences Limited (D-U-N-S 650348852).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 9, 2012–2025
- 1 OAI · 5 VAI · 3 NAI
- Inspections with 483 observations shown
- 1 of 9
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 4 requests, latest Apr 17, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- Observation 1
Deficient aseptic processing controls
OBSERVATION 1 Aseptic processing areas are deficient regarding the system Specifically, A. From May 2023 until December 2023, your intended to be sterile when your environment not in a state of control. During this time period, you documented 337 action level environmental monitoring excursions for bacterial and fungal recoveries in Grade-A and B areas [for aseptic filling line] to include critical aseptic filling areas, equipment, and personnel. Firm's actions in response to the environmental below: Your firm documented moisture and microbial contamination of environmental monitoring plates received from your supplier in July 2023 investigation IMDD-EM/23/010 (media lots). Despite documentation of the media plates themselves, your monitoring excursions for the [line] aseptic manufacturing area and the plate contamination to a contaminated incubator and continued until December 2023. In December 2023, your [firm] acceptance criteria 1 (b)(1) media lots • contaminated plates from the processing areas (line) during drug product manufacture [injection 1 mg/mL lot (b)(1) (media lot] (b)(4) • Your firm's retrospective evaluation conducted for laboratory investigation LIN- (December 2023) for a failed negative control during aseptic processing line monitoring, is inadequate as a media lot with evaluated and documented as compliant in the retrospective evaluation conducted in December 2023, however, moisture and microbial contamination (bacterial and fungal) in excursion investigation IMDD-EM/23/010. B. Your firm's airflow visualization studies (smoke studies) are inadequate; they use insufficient smoke to demonstrate unidirectional airflow and they demonstrate inadequate aseptic technique as exampled below: • Insufficient smoke was noted in the 2021 smoke study items from the HLA F to the RABS to demonstrate unidirectional non-turbulent airflow. - Shoot 10: During unloading of sterile ... smoke is visible (b)(1) the RABS to demonstrate ... - Shoot 35: During CbH assembly, no smoke is observed over the operator when critical operations are performed (for example from ...) - Shoot 36: During aseptic connection of fill tubing CbH inadequate smoke is observed near the critical area - aseptically connected to the ... • Inadequate Aseptic Technique - in shoot 35 camera ... against the fill tubing and assembly extensively contacts the tubing and ... 0318-SOP-MFG-00018 "Operation of Vial Filling and Stoppering Machine" 6.7.33, "During CbH assembling, ensure that garment should not touch the any machine part of filling and stoppering machine." The procedure is not followed with the instructions in the procedure. Procedure is inadequately designed as it requires the operator to reach over the fill line causing gowning to contact the line in multiple areas.
- Observation 2
Inadequate contamination prevention procedures
OBSERVATION 2 Procedures designed to prevent microbiological contamination are not written and followed. Specifically, A. On 3/21/2024 we inspected the aseptic ... loading the WCl for load pattern ... (b)(H) injection lot ... Per the load pattern ... position ... the noted are used to provide ... B. Your firm's sterility test procedure is inadequate as it only instructs to observe for microbial contamination via turbidity. Procedure does not include instructions for evaluation of samples present as other than turbidity (suspensions, particles, filaments).
Show 6 more observations
- Observation 3
Building maintenance and mold issues
OBSERVATION 3 Buildings used in the manufacturing, processing, packing and holding of drug products are not maintained in a good state of repair. Specifically, On 3/20/2024, we inspected the HVA / filling line ceiling. The roof of the ... had holes and visible light to the exterior. B. On 3/20/2024, we inspected the QC microbiology storage room (classified, CNC) and noted what appeared to be mold on and around the air vent in the ceiling of the room. Your firm stores various QC microbiology supplies in room including canisters for drug product sterility and environmental monitoring. C. Various areas within your facility were observed to have what appeared to be water stained ceilings indicative of prior water leakage events to include: • (b)(1), - CNC hallway leading into line • Laboratory change room (b)(4) • Corridor between retain storage room and material storage room • Drug product retain storage room
- Observation 4
Poor equipment cleaning and maintenance
OBSERVATION 4 Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity. Specifically, On 3/26/2024, we inspected vessel (b)(1) vessel ... in equipment storage area. Vessel (b)(H /MF~V/648) was inspected from the interior side. [There was] tape hanging from the (b)(T) fitting and area that appeared to be rusting. Vessel (b)(Y)(4) ... an [existing] vessel your firm utilizes ... (b)()MFqffiV/648 was utilized to manufacture ... which was shipped for the US market on ... (b)(1) of the tank and noted what appeared to be discolored ... The fitting also appeared to be discolored brown with a ... /MF~V/648 is utilized to ... (b)(Y)(4) to perform aseptic filling ... 1 (b)(1) injection ... DATES OF INSPECTION 3/18/2024-3/27/2024*
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Apr 17, 2026.
Inspection ending Nov 13, 2025
2 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Mar 27, 2026. FDAgent holds no copy that FDA posted.
- Apr 17, 2026FDA-FOIA-2026-3885Form 483Open
- Mar 3, 2026FDA-FOIA-2026-2137Form 483· 1 of 2 sitesRecords released
Inspection ending Jun 17, 2025VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Mar 20, 2026. FDAgent holds no copy that FDA posted.
- Feb 4, 2026FDA-FOIA-2026-1220Form 483· 1 of 2 sitesRecords released
Inspection ending Mar 27, 2024OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jun 18, 2024FDA-FOIA-2024-5384Inspection recordsClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 9 inspections.
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.58Maintenance1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Zydus Lifesciences LimitedD-U-N-S 650348852
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Zydus Lifesciences Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Zydus Lifesciences LimitedFEI 3012977526Ahmedabad, India
Last inspected 2026-05-05VAI
Zydus Lifesciences LimitedFEI 3013712903India
Last inspected 2025-09-05
Zydus Lifesciences LimitedFEI 3005430968India
Last inspected 2025-08-13
Zydus Lifesciences LimitedFEI 3002806475Dabhasa, Vadodara, India
Last inspected 2025-04-25VAI
Zydus Lifesciences LimitedFEI 3003696998Ankleshwar, India
Last inspected 2025-03-14NAI
Zydus Lifesciences LimitedFEI 3006026405Ahmedabad, India
Last inspected 2025-02-14NAI
Zydus Lifesciences LimitedFEI 3006809732Kalyan, India
Last inspected 2025-02-14NAI
Zydus Lifesciences LimitedFEI 3008957483Ahmedabad, India
Last inspected 2024-07-19VAI
Zydus Lifesciences LimitedFEI 3007938603Matoda, India
Last inspected 2023-03-24VAI
Zydus Lifesciences LimitedFEI 3002984011Ahmedabad, India
Last inspected 2022-08-05VAI
Not every site is listed: these are the most recently inspected sites found under this name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007621329 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007621329. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.