21 CFR 211.58: Maintenance
FDA's inspection data lists 320 Form 483 citations of 21 CFR 211.58 at 285 facilities, from November 2008 to July 31, 2026. 12 warning letters state a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 320
- At 320 inspections
- Facilities cited
- 285
- Distinct FEIs
- Most recent citation
- Jul 31, 2026
- Aizant Drug Research Solutions Private Ltd.
- Warning letters
- 12
- State a violation of it
The regulation
The current text of 21 CFR 211.58 from the Electronic Code of Federal Regulations.
§ 211.58 Maintenance.
Any building used in the manufacture, processing, packing, or holding of a drug product shall be maintained in a good state of repair.
21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart CRead on eCFR
Citations by year
Form 483 citations of 21 CFR 211.58 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 27 in 2011
| Year | Form 483 citations |
|---|---|
| 2008 | 2 |
| 2009 | 17 |
| 2010 | 21 |
| 2011 | 27 |
| 2012 | 24 |
| 2013 | 12 |
| 2014 | 15 |
| 2015 | 21 |
| 2016 | 25 |
| 2017 | 23 |
| 2018 | 25 |
| 2019 | 10 |
| 2020 | 5 |
| 2021 | 13 |
| 2022 | 14 |
| 2023 | 13 |
| 2024 | 19 |
| 2025 | 21 |
| 2026 | 13 |
How FDA words this citation
FDA's short descriptions and citation text on these 320 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Buildings not maintained in good state of repair320 citations
Citation text
- “Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.”101 citations
- “Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair.”52 citations
- “Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.”39 citations
- “Buildings used in the holding of a drug product are not maintained in a good state of repair.”28 citations
Show 2 more
- “Buildings used in the manufacturing, processing and packing of a drug product are not maintained in a good state of repair.”21 citations
- “Buildings used in the processing of a drug product are not maintained in a good state of repair.”15 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 211.58, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Aizant Drug Research Solutions Private Ltd.2026-07-31 · FEI 3008243902Buildings not maintained in good state of repair
- Element Materials Technology Boston - Acton Inc.2026-05-04 · FEI 1000148174Buildings not maintained in good state of repair
- Granules Pharmaceuticals Inc.2026-04-03 · FEI 3011585184Buildings not maintained in good state of repair
Show 4 more
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.58 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 10 observations tie this way. The highlighted sentence is the matched wording.
STAQ Pharma Inc2026-09-08 · Observation 1
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair. Specifically, your firm does not maintain your facility adequately to prevent water intrusion into the mezzanine space directly above ISO-7 spaces utilized to produce injectable drug products purported to be sterile. On August 27, 2026, I observed standing water on top of non-impervious flooring within the …
This observation opens with FDA's standard wording for 21 CFR 211.58.
Lyophilization Services of New England, Inc.2026-06-10 · Observation 6
Buildings used in the manufacturing and processing of a drug product are not maintained in a good state of repair. Specifically, on 6/1/2026, a divot approximately two to four inches long was observed approximately one foot off the ground on the corner of a wall pillar in ISO-5 Room 149A Sterile Staging, Building 25 Commerce, immediately next to the exit door of the (b)(4) oven. Similarly, on 6/2/2026, a floor divot approximately one inch in …
This observation opens with FDA's standard wording for 21 CFR 211.58.
Nice-Pak Products, Inc.2026-04-20 · Observation 3
Buildings used in the manufacturing of a drug product are not maintained in a good state of repair. Specifically, Ceiling tiles located directly above active manufacturing equipment and the production line were observed to be damaged, missing, and visibly contaminated. Numerous tiles exhibited water stains, dirt, and large, dark patches consistent in appearance with mold, creating a direct risk of contamination to exposed drug products and …
This observation opens with FDA's standard wording for 21 CFR 211.58.
Show 2 more
Neeyaan LLC2026-01-27 · Observation 11
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair. Specifically, On 01/21/2026, visible damage and black/brown stains were observed on the HEPA filters on the ceiling in Compression Room ^(b) (4) above the ^(b) (4) Tooling Tablet Press (b) (4) which was used to compress (b) (4) tablets Lot #(b) (4). No preventative maintenance program exists for the HEPA filters.
This observation opens with FDA's standard wording for 21 CFR 211.58.
Genzyme Ireland Limited2026-01-20 · Observation 3
Buildings used in the manufacturing, processing and holding of a drug product are not maintained in a good state of repair. Specifically, the following conditions were observed in your fill/finish manufacturing areas during the current inspection: A) On January 13, 2026, in Room (b) (4) (Fill Line (b) (4)) the (b) (4) exhibited two "X" shaped cracks that were actively extruding water during the (b) (4) operations utilizing (b) (4) The …
This observation opens with FDA's standard wording for 21 CFR 211.58.
Warning letters stating a violation of 21 CFR 211.58
12 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes. Your firm also failed to maintain buildings used in the manufacture, processing, packing, or holding of drug products in a good state of repair (21 CFR 211.113(b) and 21 CFR 211.58).”
- Jabil Inc.Issued 2026-08-27
“You failed to maintain buildings used in the manufacture, processing, packing or holding of drug products in a good state of repair (21 CFR 211.58).”
- Fagron BVIssued 2026-05-12
“Your firm failed to maintain buildings used in the manufacture, processing, packing, or holding of drug products in a good state of repair (21 CFR 211.58).”
Each letter below states the violation in these words.
- Patcos Cosmetics Pvt. Ltd.Issued 2026-03-12
- Winder Laboratories, LLCIssued 2026-01-07
- Rechon Life Science ABIssued 2025-04-30
- Granules India LimitedIssued 2025-02-26
Often cited at the same inspection
Of the 320 inspections where FDA cited 21 CFR 211.58, the share where it also cited each of these sections.
- 21 CFR 211.67Equipment cleaning and maintenance158 (49%)
- 21 CFR 211.22Responsibilities of quality control unit154 (48%)
- 21 CFR 211.192Production record review116 (36%)
- 21 CFR 211.100Written procedures; deviations115 (36%)
- 21 CFR 211.160General requirements113 (35%)
- 21 CFR 211.165Testing and release for distribution87 (27%)
Ask FDAgent about 21 CFR 211.58
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.58; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.