Skip to content

Gasco Industrial Corp.

Calle A Lote 3 Rincon Indus Park, Gurabo, Puerto Rico, United States

FEI 3010222586DUNS 616206756

FDA has 7 inspections on file for Gasco Industrial Corp. in Gurabo, Puerto Rico (FEI 3010222586), from 2010 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the six FOIA requests for this site have asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations II). No court action or import refusal is filed under this FEI.

Seven regulations were cited at more than one inspection; they are listed below.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Dan N. Bigman-Montalvo (D-U-N-S 616206756).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
7, 2010–2026
4 OAI · 2 VAI · 1 NAI
Inspections with 483 observations shown
4 of 7
2 with citations published, text not held
Form 483s posted by FDA
↗
Requested under FOIA
6 requests, latest Jun 18, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 13 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    2. Failing drug products not rejected

      Drug products failing to meet established standards, specifications and quality control criteria are not rejected.

    3. Complaint Investigation/Follow-Up Findings

      Complaint records are deficient in that they do not include the findings of the investigation and follow-up.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.

    5. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.

    Show 8 more citations
    1. Identification of Person Performing Review of Lab Records

      Laboratory records are deficient in that they do not include the initials and signature of the second person reviewing the record for accuracy.

    2. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written and followed.

    3. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    4. Written calibration procedures

      Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions, schedules, limits for accuracy and precision and provisions for remedial action if limits are not met.

    5. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    6. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    7. Reserve samples identified, representative, stored

      Reserve drug product samples are not appropriately identified, representative of each lot or batch of drug product and retained and stored under conditions consistent with product labeling.

    8. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Failing drug products not rejected

      Drug products failing to meet established standards, specifications and quality control criteria are not rejected.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    4. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    5. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    Show 2 more citations
    1. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    2. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    2. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    3. Failing drug products not rejected

      Drug products failing to meet established specifications are not rejected.

    4. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.

    5. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations published; text not held
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceCitations published; text not held
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Identification of containers, lines, equipment

      All compounding and storage containers used during the production of a batch of drug product is not properly identified at all times to indicate contents.

    2. Calibration/Inspection/Checking not done

      Routine calibration, inspection, and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

    3. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    4. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    5. Drug products-sampling procedures/specifications

      Laboratory controls do not include a determination of conformance to appropriate specifications for drug products.

    Show 7 more citations
    1. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    2. Status of Each Lot Identified

      Each lot of components, drug product containers, and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.

    3. Lack of quality control unit

      There is no quality control unit.

    4. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not established.

    5. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    6. Cleaning/maintenance records not kept

      Records are not kept for the maintenance, cleaning, sanitizing, and inspection of equipment.

    7. Written Procedures Not Followed

      Written procedures are not followed for the identification, handling, sampling, testing, and approval of components, drug product containers, and closures.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Six requests to FDA under the Freedom of Information Act named this site, most recently on Jun 18, 2026. Each one asked for a Form 483.

  • Inspection ending Feb 27, 2026OAI

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jun 18, 2026FDA-FOIA-2026-5914Form 483Merged with another request
    2. Jun 18, 2026FDA-FOIA-2026-5912Form 483Records released
    3. Apr 21, 2026FDA-FOIA-2026-4025Form 483· 1 of 5 sitesRecords released
  • Inspection ending Dec 8, 2023OAI

    2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 17, 2024FDA-FOIA-2024-6306Form 483Closed
    2. Jan 4, 2024FDA-FOIA-2024-127Form 483Closed
  • Inspection ending Oct 18, 2022OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Jul 17, 2024FDA-FOIA-2024-6305Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 17 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 7 inspections, with how many of them cited each.

Show all 17

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
Dan N. Bigman-MontalvoD-U-N-S 616206756

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010222586 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010222586. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.