21 CFR 211.84: Testing and approval or rejection of components, drug product containers, and closures
FDA's inspection data lists 1,818 Form 483 citations of 21 CFR 211.84 at 1,205 facilities, from October 2008 to August 24, 2026. 223 warning letters state a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 1,818
- At 1,564 inspections
- Facilities cited
- 1,205
- Distinct FEIs
- Most recent citation
- Aug 24, 2026
- Noven Pharmaceuticals, Inc.
- Warning letters
- 223
- State a violation of it
The regulation
The current text of 21 CFR 211.84 from the Electronic Code of Federal Regulations.
§ 211.84 Testing and approval or rejection of components, drug product containers, and closures.
(a) Each lot of components, drug product containers, and closures shall be withheld from use until the lot has been sampled, tested, or examined, as appropriate, and released for use by the quality control unit.
(b) Representative samples of each shipment of each lot shall be collected for testing or examination. The number of containers to be sampled, and the amount of material to be taken from each container, shall be based upon appropriate criteria such as statistical criteria for component variability, confidence levels, and degree of precision desired, the past quality history of the supplier, and the quantity needed for analysis and reserve where required by § 211.170.
(c) Samples shall be collected in accordance with the following procedures:
(1) The containers of components selected shall be cleaned when necessary in a manner to prevent introduction of contaminants into the component.
(2) The containers shall be opened, sampled, and resealed in a manner designed to prevent contamination of their contents and contamination of other components, drug product containers, or closures.
(3) Sterile equipment and aseptic sampling techniques shall be used when necessary.
(4) If it is necessary to sample a component from the top, middle, and bottom of its container, such sample subdivisions shall not be composited for testing.
(5) Sample containers shall be identified so that the following information can be determined: name of the material sampled, the lot number, the container from which the sample was taken, the date on which the sample was taken, and the name of the person who collected the sample.
(6) Containers from which samples have been taken shall be marked to show that samples have been removed from them.
(d) Samples shall be examined and tested as follows:
(1) At least one test shall be conducted to verify the identity of each component of a drug product. Specific identity tests, if they exist, shall be used.
(2) Each component shall be tested for conformity with all appropriate written specifications for purity, strength, and quality. In lieu of such testing by the manufacturer, a report of analysis may be accepted from the supplier of a component, provided that at least one specific identity test is conducted on such component by the manufacturer, and provided that the manufacturer establishes the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
(3) Containers and closures shall be tested for conformity with all appropriate written specifications. In lieu of such testing by the manufacturer, a certificate of testing may be accepted from the supplier, provided that at least a visual identification is conducted on such containers/closures by the manufacturer and provided that the manufacturer establishes the reliability of the supplier's test results through appropriate validation of the supplier's test results at appropriate intervals.
(4) When appropriate, components shall be microscopically examined.
(5) Each lot of a component, drug product container, or closure that is liable to contamination with filth, insect infestation, or other extraneous adulterant shall be examined against established specifications for such contamination.
(6) Each lot of a component, drug product container, or closure with potential for microbiological contamination that is objectionable in view of its intended use shall be subjected to microbiological tests before use.
(e) Any lot of components, drug product containers, or closures that meets the appropriate written specifications of identity, strength, quality, and purity and related tests under paragraph (d) of this section may be approved and released for use. Any lot of such material that does not meet such specifications shall be rejected.
21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart ERead on eCFR
Citations by year
Form 483 citations of 21 CFR 211.84 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 147 in 2025
| Year | Form 483 citations |
|---|---|
| 2008 | 18 |
| 2009 | 113 |
| 2010 | 121 |
| 2011 | 139 |
| 2012 | 143 |
| 2013 | 106 |
| 2014 | 90 |
| 2015 | 93 |
| 2016 | 96 |
| 2017 | 116 |
| 2018 | 99 |
| 2019 | 99 |
| 2020 | 23 |
| 2021 | 49 |
| 2022 | 75 |
| 2023 | 108 |
| 2024 | 119 |
| 2025 | 147 |
| 2026 | 64 |
How FDA words this citation
FDA's short descriptions and citation text on these 1,818 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Reports of Analysis (Components)433 citations
- Identity Testing of Each Component259 citations
- Establish reliability of supplier's C of A197 citations
- Components withheld from use pending release151 citations
- Testing Each Component for Conformity with Specs122 citations
Show 3 more
- Component identity verification115 citations
- Representative Samples89 citations
- Component identification test86 citations
Citation text
- “The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.”258 citations
- “Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.”212 citations
- “Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.”190 citations
- “Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.”180 citations
Show 2 more
- “Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.”121 citations
- “Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.”115 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 211.84, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Show 4 more
- Advanced Accelerator Applications USA, Inc.2026-08-11 · FEI 3012484129Component written specification
- Aizant Drug Research Solutions Private Ltd.2026-07-31 · FEI 3008243902Identity Testing of Each Component
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.84 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 31 observations tie this way. The highlighted sentence is the matched wording.
OPS International Inc dba Olympia Pharmaceuticals2026-09-03 · Observation 7
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, (A) SOP-035, Procurement, Receipt, and Inspection of Incoming Components and Materials, does not include a sampling plan specifying the number of containers to be sampled per shipment. According to the Senior Supply Chain Manager, (b)(4) sent from your (b)(4) warehouse to …
This observation opens with FDA's standard wording for 21 CFR 211.84(d)(2).
Apollo Care LLC2026-07-28 · Observation 5
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, A) You do not test all received containers of at-risk API raw material (b)(4) for potential contamination with (b)(4) and (b)(4). You release raw material (b)(4) for compounding sterile human injectable drugs based upon review of the supplier CoA. You use (b)(4) limited lot AC-017165. B) Your firm releases …
This observation opens with FDA's standard wording for 21 CFR 211.84(d)(2).
Cascade Specialty Pharmacy LLC2026-07-17 · Observation 5
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis. Specifically, Your firm accepts the material based on the supplier's certificate of analysis in lieu of testing each component received. However, your firm does not perform identity tests on each component received to ensure that the component received has the purported identity. The following components were accepted …
This observation opens with FDA's standard wording for 21 CFR 211.84(d)(2).
Show 2 more
Jubilant HollisterStier LLC2026-06-17 · Observation 1
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, your firm does not always perform complete identification testing of raw materials (b)(4) that is used as an ingredient in the manufacture of your (b)(4) injection and (b)(4) solution (b)(4) products. For (b)(4) raw materials supplied to you by your client used in the …
This observation opens with FDA's standard wording for 21 CFR 211.84(d)(2).
Bentley Laboratories LLC2026-03-27 · Observation 1
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier’s analyses through appropriate validation of the supplier's test results at appropriate intervals. Specifically, 1) Only FTIR identification test is performed on each shipment …
This observation opens with FDA's standard wording for 21 CFR 211.84(d)(2).
Warning letters stating a violation of 21 CFR 211.84
223 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your firm failed to conduct at least one test to verify the identity of each component of a drug product (21 CFR 211.84(d)(1)).”
Each letter below states the violation in these words.
- Natural Essentials, Inc.Issued 2026-11-10
- Sanrace Biotechnology Co., Ltd.Issued 2026-10-22
“Your firm failed to conduct at least one test to verify the identity of each component of a drug product. Your firm also failed to validate and establish the reliability of your component supplier’s test analyses at appropriate intervals (21 CFR 211.84(d)(1) and 211.84(d)(2)).”
Each letter below states the violation in these words.
- Pritam International Private LimitedIssued 2026-10-27
- TSP Solutions Pte. Ltd.Issued 2026-10-22
- Zhejiang Gaorong Cosmetic Co., Ltd.Issued 2026-10-01
“Your firm failed to test samples of each component for identity and conformity with all appropriate written specifications for purity, strength, and quality (21 CFR 211.84(d)(1) and 211.84(d)(2)).”
- Guangdong Bangze Medicine Co., Ltd.Issued 2026-10-26
Often cited at the same inspection
Of the 1,564 inspections where FDA cited 21 CFR 211.84, the share where it also cited each of these sections.
- 21 CFR 211.22Responsibilities of quality control unit793 (51%)
- 21 CFR 211.100Written procedures; deviations693 (44%)
- 21 CFR 211.67Equipment cleaning and maintenance656 (42%)
- 21 CFR 211.165Testing and release for distribution603 (39%)
- 21 CFR 211.166Stability testing600 (38%)
- 21 CFR 211.160General requirements585 (37%)
Ask FDAgent about 21 CFR 211.84
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
Topics that count this section:Supplier controls
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.84; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.