Skip to content

Cascade Specialty Pharmacy LLC

Washington

FEI 3015133983

FDA has one inspection on file for Cascade Specialty Pharmacy LLC in Washington (FEI 3015133983). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2026
Inspections with 483 observations shown
1 of 1
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 6 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Missing container/closure details

      The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your firm's written procedure designates the pharmacist as responsible for ensuring the accuracy of compounding records and performing quality checks requiring pharmacist verification. However, your firm's compounding record does not specify container and closure to use to ensure they are adequate for its intended pharmaceutical usage. For example: your firm manufactured Gabapentin 100 mg/mL Suspension Stock Solution Lot 656519 that may be used in the production of patient-specific drugs. This stock solution can be stored for up to [(b)(4)] per the compounding record. The compounding record for Gabapentin 100 mg/mL Suspension Stock Solution Lot 656519, used in the production of patient dosage Lot 657408, does not describe the container and closure system in sufficient detail. The record states only "Bottle with Insert and Dosing Syringe." without specifying the material or type of container. This level of detail is inadequate to ensure that the selected container and closure system is appropriate for long-term storage of up to [(b)(4)] and does not provide sufficient assurance against degradation due to leaching, permeability, or inadequate sealing over the storage period.

    2. Observation 2

      Incomplete batch production records

      Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, A. Amoxicillin/Clavulanate Pot 250 mg/mL Suspension Lot 657973 (RX# F wxc1) Your firm's compounding record does not specify the method to be used for crushing or dissolving tablets during production. The instructions for tablet pulverization do not indicate the required duration of pulverization needed to achieve a uniform particle size, nor do they specify how many tablets are to be pulverized at one time. Without these critical parameters, the production process cannot be reliably reproduced across different operators, and there is no assurance that the resulting suspension will have uniform particle size distribution. B. Methimazole Lipo 5 mg/0.1 mL Cream Lot 654534 (RX# [illegible]) Your firm's compounding record instructs the operator to "Place into specified container for patient use," identified as a 1 mL syringe. However, the record provides no instructions describing how the product is to be transferred from the production container into the 1 mL syringe. There are no steps to ensure complete transfer of the product, accurate fill volume, or consistency across units.

    Show observations 3 to 6
    1. Observation 3

      No cleaning/maintenance procedures

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, Your firm has not conducted an in-house efficacy study to verify the effectiveness of the deactivating agent used for beta-lactam residue on production equipment from manufacturing and handling beta-lactam drug substances, or to confirm that the contact time employed by your firm is sufficient to achieve adequate deactivation. Instead, your firm relies solely on the manufacturer's claims to establish the suitability of the deactivating agent for its intended use. There is no in-house scientific data to support the adequacy of the agent or that the contact time your firm uses is adequate for the non-dedicated work area where beta-lactam and other non-sterile hazardous drugs are produced.

    2. Observation 4

      No finished product identity/strength testing

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. Specifically, Your firm performs routine potency testing only on in-process materials for Levothyroxine Sodium and Liothyronine Sodium. Your firm does not perform routine finished product testing on manufactured drug products. For example: A. Trilostane Capsule 58 mg Lot 660349 (RX# [illegible]) Your firm did not perform identity or strength testing on this finished drug product prior to release. Conformance to the labeled potency of 58 mg was not analytically verified; release was based solely on theoretical potency calculated from the quantities of components used during production. B. Gabapentin 100 mg/mL Suspension Lot 657408 (RX# [illegible]) Your firm did not perform identity or strength testing on this finished drug product prior to release. Conformance to the labeled concentration of 100 mg/mL was not analytically verified; release was based solely on theoretical potency calculated from the quantities of stock solution used during production. The stock solution used, Gabapentin 100 mg/mL Suspension Stock Solution Lot 656519, itself was not tested for its potency after the production.

    3. Observation 5

      No identity testing of components

      Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis. Specifically, Your firm accepts the material based on the supplier's certificate of analysis in lieu of testing each component received. However, your firm does not perform identity tests on each component received to ensure that the component received has the purported identity. The following components were accepted solely based on the supplier's COA without performing any identity testing: A. Trilostane powder Lot [(b)(4)], which was used to compound Trilostane Capsule 58 mg lot 660349, was accepted without any identity testing. Only the CoA of supplier was used for release for usage. B. Methimazole powder lot [(b)(4)], which was used to compound Methimazole Stock solution 10 mg/mL lot 647915, was accepted without any identity testing. Only the CoA of supplier was used for release for usage. C. Itraconazole powder lot [(b)(4)], which was used to compound Itraconazole 25 mg/mL Suspension lot 652087, was accepted without any identity testing. Only the CoA of supplier was used for release for usage. In addition, your firm has not demonstrated the reliability of your suppliers' COAs through adequate validation or testing at appropriate intervals.

    4. Observation 6

      No written stability testing program

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm does not have a written stability testing program to determine the beyond use date for each drug product. Your firm assigns beyond use date based on the [(b)(4)], which is based on either stability testing performed by another entity for in-process stock, or based on the dosage form and the storage condition.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3015133983 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3015133983. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.