- Inspection
- Jul 6–17, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Jul 31, 2026
- 14 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Missing container/closure details
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, Your firm's written procedure designates the pharmacist as responsible for ensuring the accuracy of compounding records and performing quality checks requiring pharmacist verification. However, your firm's compounding record does not specify container and closure to use to ensure they are adequate for its intended pharmaceutical usage. For example: your firm manufactured Gabapentin 100 mg/mL Suspension Stock Solution Lot 656519 that may be used in the production of patient-specific drugs. This stock solution can be stored for up to [(b)(4)] per the compounding record. The compounding record for Gabapentin 100 mg/mL Suspension Stock Solution Lot 656519, used in the production of patient dosage Lot 657408, does not describe the container and closure system in sufficient detail. The record states only "Bottle with Insert and Dosing Syringe." without specifying the material or type of container. This level of detail is inadequate to ensure that the selected container and closure system is appropriate for long-term storage of up to [(b)(4)] and does not provide sufficient assurance against degradation due to leaching, permeability, or inadequate sealing over the storage period.
- 2
Incomplete batch production records
Batch production and control records do not include complete information relating to the production and control of each batch. Specifically, A. Amoxicillin/Clavulanate Pot 250 mg/mL Suspension Lot 657973 (RX# F wxc1) Your firm's compounding record does not specify the method to be used for crushing or dissolving tablets during production. The instructions for tablet pulverization do not indicate the required duration of pulverization needed to achieve a uniform particle size, nor do they specify how many tablets are to be pulverized at one time. Without these critical parameters, the production process cannot be reliably reproduced across different operators, and there is no assurance that the resulting suspension will have uniform particle size distribution. B. Methimazole Lipo 5 mg/0.1 mL Cream Lot 654534 (RX# [illegible]) Your firm's compounding record instructs the operator to "Place into specified container for patient use," identified as a 1 mL syringe. However, the record provides no instructions describing how the product is to be transferred from the production container into the 1 mL syringe. There are no steps to ensure complete transfer of the product, accurate fill volume, or consistency across units.
- 3
No cleaning/maintenance procedures
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, Your firm has not conducted an in-house efficacy study to verify the effectiveness of the deactivating agent used for beta-lactam residue on production equipment from manufacturing and handling beta-lactam drug substances, or to confirm that the contact time employed by your firm is sufficient to achieve adequate deactivation. Instead, your firm relies solely on the manufacturer's claims to establish the suitability of the deactivating agent for its intended use. There is no in-house scientific data to support the adequacy of the agent or that the contact time your firm uses is adequate for the non-dedicated work area where beta-lactam and other non-sterile hazardous drugs are produced.
- 4
No finished product identity/strength testing
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. Specifically, Your firm performs routine potency testing only on in-process materials for Levothyroxine Sodium and Liothyronine Sodium. Your firm does not perform routine finished product testing on manufactured drug products. For example: A. Trilostane Capsule 58 mg Lot 660349 (RX# [illegible]) Your firm did not perform identity or strength testing on this finished drug product prior to release. Conformance to the labeled potency of 58 mg was not analytically verified; release was based solely on theoretical potency calculated from the quantities of components used during production. B. Gabapentin 100 mg/mL Suspension Lot 657408 (RX# [illegible]) Your firm did not perform identity or strength testing on this finished drug product prior to release. Conformance to the labeled concentration of 100 mg/mL was not analytically verified; release was based solely on theoretical potency calculated from the quantities of stock solution used during production. The stock solution used, Gabapentin 100 mg/mL Suspension Stock Solution Lot 656519, itself was not tested for its potency after the production.
- 5
No identity testing of components
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis. Specifically, Your firm accepts the material based on the supplier's certificate of analysis in lieu of testing each component received. However, your firm does not perform identity tests on each component received to ensure that the component received has the purported identity. The following components were accepted solely based on the supplier's COA without performing any identity testing: A. Trilostane powder Lot [(b)(4)], which was used to compound Trilostane Capsule 58 mg lot 660349, was accepted without any identity testing. Only the CoA of supplier was used for release for usage. B. Methimazole powder lot [(b)(4)], which was used to compound Methimazole Stock solution 10 mg/mL lot 647915, was accepted without any identity testing. Only the CoA of supplier was used for release for usage. C. Itraconazole powder lot [(b)(4)], which was used to compound Itraconazole 25 mg/mL Suspension lot 652087, was accepted without any identity testing. Only the CoA of supplier was used for release for usage. In addition, your firm has not demonstrated the reliability of your suppliers' COAs through adequate validation or testing at appropriate intervals.
- 6
No written stability testing program
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm does not have a written stability testing program to determine the beyond use date for each drug product. Your firm assigns beyond use date based on the [(b)(4)], which is based on either stability testing performed by another entity for in-process stock, or based on the dosage form and the storage condition.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3015133983, newest first.
- Form 483, April 2019FDA record date Apr 17, 2019 · Posted Mar 12, 2026
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.