OPS International Inc dba Olympia Pharmaceuticals
Florida
FEI 3009724085
FDA has 6 inspections on file for OPS International Inc dba Olympia Pharmaceuticals in Florida (FEI 3009724085), from 2013 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Aug 8, 2025. FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.
Eight regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 6, 2013–2026
- 3 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 6 of 6
- 3 posted 483s not matched to an inspection
- Requested under FOIA
- 3 requests, latest Oct 1, 2024
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetPosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Deficient aseptic environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, (A) The firm's environmental monitoring procedure does not require viable environmental monitoring during the initial aseptic setup of the (b)(4) filling line within the (b)(4) or during the initial aseptic setup of the (b)(4) automated filling machine positioned under [illegible] HEPA-filtered unidirectional airflow enclosure. Per SOP-009, Environmental Monitoring of the Controlled Production Areas, environmental monitoring is not required to commence until aseptic connections setup activities have occurred. (1) On August 26, 2026, we observed operator performing set-up of the (b)(4) for the (b)(4) automated filling machine (Equipment ID #(b)(4)) for the filling of Calcium Chloride (Lot #H24A01-26). No environmental monitoring plates were present within the ISO 5 critical area under the (b)(4) unidirectional airflow unit during this setup activity. (2) According to the batch record for Myer's Cocktail (Lot #G27A05-26, Exp. 26 Nov 2026), equipment set-up of the (b)(4) auto filler, located inside the ISO (b)(4) in Suite (b)(4) began at 08:01. The first passive air sample was not opened until 08:21 on 30 July 2026. (B) The firm's personnel monitoring program does not include microbiological monitoring of gown locations for Sterile Techs who perform set-up of the (b)(4) filling line or set-up of the (b)(4) automated filling machine. Gown monitoring at a defined schedule, supported by scientific justification, is not included in the program. (1) On August 21, 2026, we observed Sterile Tech performing line setup for the filling of Biotin 0.5 mg/mL (Lot #H17A05-26) with his head, body, and sleeves inside the ISO 5 (b)(4) chamber without any concurrent personnel monitoring. (2) On August 26, 2026, we observed Sterile Tech performing set up for the filling of Calcium Chloride (Lot #H24A01-26) with his sleeves inside the ISO 5 (b)(4) HEPA-filtered unidirectional airflow enclosure (LAFW-(b)(4)). The (b)(4) automated (b)(4) filling machine operates under (b)(4) HEPA-filtered unidirectional airflow enclosure with no physical barrier between the filling operation and the operator. (C) Gloved fingertip monitoring of the Sterile Tech is performed only following completion of the aseptic filling production shift.
- Observation 2
Inadequate sterile contamination prevention procedures
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, (A) Your firm has not adequately demonstrated that (b)(4)-sterilized machine (b)(4) parts and accessories used in aseptic filling maintain their sterile state during the established (b)(4) sterilization hold time in a controlled, non-classified area. The supporting microbiological evaluation consisted of swabbing part surfaces and incubating samples in (b)(4) medium at (b)(4) for (b)(4). (1) Your firm has not provided adequate scientific justification that these incubation conditions are suitable for recovering and detecting microorganisms that may be encountered if the sterile barrier is compromised during storage within the non-classified area. (2) The provided record associated with the sampling, in-house incubation, and results of the swab samples lacked the following critical information: Actual incubation temperature; Date and time samples were placed in the incubator; Date and time samples were removed from the incubator; Identity of the person who read the results. (3) According to your Senior Quality Manager and Senior Director of Compliance, following the in-house incubation of the swab samples, the samples were sent to your contract laboratory for sterility testing; however, the associated records, including the third-party sterility test results, could not be located. (B) On August 21, 2026, during aseptic setup of the (b)(4) filling line for Biotin 0.5 mg/mL (Lot #H17A05-26), [illegible] Chamber (Material Chamber) (b)(4) surfaces to the ISO 7 environment. Subsequently the (b)(4) were [illegible] without disinfecting the exposed (b)(4) surfaces, thereby reintroducing ISO 7 environmentally exposed surfaces into the ISO 5 critical area. (C) Your firm has not adequately established a visual inspector qualification program to demonstrate that personnel can consistently and reliably detect microbial growth during the visual inspection of media-filled units. (1) Your challenge qualification [illegible] contain (b)(4) prepared with (b)(4) in (b)(4) vials and (b)(4). Your firm has no documented scientific justification for the use of (b)(4) as a surrogate for actual microbial contamination/turbidity. (2) There is no documented justification for the number, type, and distribution of positive units to demonstrate reliable contamination detection in media fills filled in (b)(4) vials. (3) (b)(4) vials are used to simulate your (b)(4) mL and (b)(4) mL vialing process during aseptic process simulation (APS). You have not evaluated whether turbidity can be adequately detected in these vials. (D) Your 2026 smoke studies, conducted as per PRO-029-01, Smoke Study Protocol, and PRO-029-03, (b)(4) Airflow Visualization Protocol, did not adequately qualify unidirectional airflow or demonstrate first air and acceptable airflow patterns during critical operations. For example: (1) Airflow patterns could not be adequately assessed in multiple (b)(4) chambers and the (b)(4) HEPA-filtered unidirectional airflow unit due to obstructions, glare, inadequate smoke introduction technique, and/or camera angle limitations (e.g. (b)(4) Chamber video; (b)(4) video). (2) In (b)(4) Chamber turbulent eddies were observed near a (b)(4) (~3:26-4:22), and smoke was observed exiting and briefly re-entering the chamber near the top when the (b)(4) were (b)(4) during setup (video time point: ~4:40-4:55). (3) The studies simulated routine activities, including line setup, loading of vials, stoppers and caps, and cleaning; however, the only corrective intervention evaluated was removal of a vial from the filling line using [illegible]. Your firm did not provide an adequate assessment demonstrating that the interventions selected represent reasonably foreseeable corrective interventions and worst-case aseptic manipulations during production. The affected equipment includes: (b)(4) in Suite (b)(4) housing the (b)
Shortened here; the PDF has the full text.
Show observations 3 to 8
- Observation 3
Production procedures not followed and documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance. Specifically, (B) Batch record review of Myer's Cocktail (Lot #G27A05-26, Exp. 26 Nov 2026) revealed that equipment set-up of the (b)(4) filling line, located inside the ISO 5 (b)(4) in Suite (b)(4) began on 30 July 2026 at 08:01 and was completed by Sterile Tech at 08:06 on 30 July 2026 — a total elapsed time of five minutes. However, set-up encompassed installation of (b)(4) chambers: (b)(4) where each require multiple set up steps. For example, the (b)(4) chamber alone required the installation of multiple components, including the (b)(4), and other associated parts. (C) Visual inspectors did not perform [illegible] via (b)(4) as required by Section 9.3 of SOP-007, Visual Inspection of Sterile Drug Products, and inspection steps performed in practice differed from those written in the procedure. (1) On August 20, 2026, Sterile Tech was observed conducting visual inspection of Amino Blend (Lot #H11A03-26) and failed to perform vial (b)(4). When subsequently asked to describe the inspection procedure, Sterile Tech was again unable to identify vial (b)(4) as a required step. (2) On August 21, 2026, Sterile Tech was observed performing visual inspection of Biotin 0.5 mg/mL (Lot #H17A05-26) and similarly failed to perform vial (b)(4). (D) On September 1, 2026, the (b)(4) (Equipment ID: (b)(4)) was observed loaded with [illegible] on (b)(4) on August 28, 2026. Notably, the (b)(4) was loaded with (b)(4); however, your currently approved procedure, SOA-040-01, Sterilization Load Configurations, effective 05 June 2026, specifies a (b)(4) load pattern diagram of only (b)(4).
- Observation 4
Inadequate visual inspection qualification procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, the (b)(4) visual inspection qualification (b)(4) used to qualify personnel performing 100% visual inspection of injectable drug products are not adequately characterized or designed to challenge inspectors' ability to detect particulates at or near the threshold of visual detectability. For example: (A) Your firm has not established the size or size range of the particulate defects contained in the qualification units intended to challenge visual inspectors to detect the smallest contaminants possible for an inspector with 20/20 vision. Although (b)(4) defect vials containing particulates were submitted for size characterization, the analysis was performed using the particle-size distribution method described in USP <429>, as documented in the Certificates of Analysis. The resulting data do not establish the size of the individual particulate defect contained in each qualification unit. (B) No written procedures or records exist documenting the preparation and contents of each particulate defect unit, including particulate type, size or size range, and method of preparation. This information is known only to the individual who prepared the qualification (b)(4).
- Observation 5
Stability program lacks stability-indicating methods
The written stability program for drug products does not include reliable, meaningful and specific test methods. Specifically, your firm assigns a (b)(4) beyond-use date (BUD) to Sermorelin Acetate 0.9 mg/mL Injection based on your contract laboratory stability study. However, your firm failed to provide adequate demonstration that the analytical procedure can detect relevant degradation-related changes. Your method validation report for Sermorelin Acetate, approved on August 22, 2025, does not include a mass balance assessment to demonstrate that the analytical method can adequately account for the drug substance and its degradation products, supporting the method's stability-indicating capability and reliability.
- Observation 6
Deficient segregation for sterilized parts storage
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, (A) Your firm utilizes (b)(4) QA-access-controlled cabinets for the storage of sterilized machine (b)(4) parts and accessories. During inspection of these cabinets (b)(4) components, including a stopper bowl that directly contacts product stoppers, were observed without sterilization-status labels. The components lacked information identifying the applicable (b)(4) and sterilization date needed for personnel to determine whether the established sterile hold time had been exceeded. (B) Sterilization-status labels are generated by operators; however, the firm did not demonstrate a system for reconciling generated labels to the individual equipment parts associated with each sterilization cycle.
- Observation 7
Deficient component sampling and testing
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, (A) SOP-035, Procurement, Receipt, and Inspection of Incoming Components and Materials, does not include a sampling plan specifying the number of containers to be sampled per shipment. According to the Senior Supply Chain Manager, (b)(4) sent from your (b)(4) warehouse to your facility for sampling. Additionally, no documentation exists for the sampling performed. (B) Your firm failed to perform a specific identity test that includes a methanol limit test on each container of each lot of ethyl alcohol used as a pharmaceutical ingredient. On May 12, 2025, your firm received, sampled, and [illegible] bottles of (b)(4) Ethyl Alcohol (b)(4) Proof (Batch #(b)(4)); (b)(4) methanol limit testing was not performed. This lot was used in the production of T-105 Injection (Papaverine Hydrochloride 30 mg/mL; Phentolamine Mesylate 1 mg/mL; Alprostadil 0.01 mg/mL), Lot #G08A10-26, BUD 04 JUL 2027. (C) Your firm failed to test each container of each lot of glycerin, used as a pharmaceutical ingredient, for diethylene glycol (DEG) or ethylene glycol (EG) contamination. Your firm did not provide a scientifically sound justification, supported by statistical analysis, for reduced sampling. On September 25, 2025, your firm received (b)(4) bottles of (b)(4) Glycerin, NF (b)(4) (Lot #(b)(4)); however, (b)(4) sampled and tested for this shipment. Additionally, Lot #(b)(4) was tested only for Identification A and was not tested for DEG and EG prior to release for use. This lot was used in the production of Glycerin 48% / Lidocaine 0.33% Injection (Lot #E20A10-26; BUD 10 JAN 2027).
- Observation 8
Batch additions lack second-person verification
Each component is not added to the batch by one person and verified by a second person. Specifically, a review of the batch record for Myer's Cocktail (Lot #(b)(4), Exp. (b)(4)) revealed that ingredients were added between (b)(4) on July 29, 2026, with no documented contemporaneous verification recorded after each individual addition. Instead, a single verification timestamp of (b)(4) was documented for this manufacturing step, more than two hours after the last ingredient was added.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the to produce aseptic conditions.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
- FDCA 503B(b)(2)(A)
All inclusive product report, not submitted
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Show 2 more citations
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Show 2 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written program not followed
The written stability testing program is not followed.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Show 2 more citations
Product flow through building is inadequate
The flow of components, drug product containers, closures, in-process materials, and drug products though the building is not designed to prevent contamination.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Show 7 more citations
Air Supply
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Containers & Closures Clean, Sterilized, Pyrogen-free
Drug product containers and closures were not clean and sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Oct 1, 2024.
Inspection ending May 29, 2024OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 24, 2024FDA-FOIA-2024-6518Form 483· 1 of 5 sitesClosed
- Jul 10, 2024FDA-FOIA-2024-6043Form 483Withdrawn
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Oct 1, 2024FDA-FOIA-2024-8515Inspection records· 1 of 2 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features5 of 5
- 21 CFR 211.113Control of microbiological contamination5 of 5
- 21 CFR 211.165Testing and release for distribution3 of 5
- 21 CFR 211.28Personnel responsibilities2 of 5
- 21 CFR 211.100Written procedures; deviations2 of 5
- 21 CFR 211.166Stability testing2 of 5
- 21 CFR 211.22Responsibilities of quality control unit1 of 5
- 21 CFR 211.63Equipment design, size, and location1 of 5
Show all 13
- 21 CFR 211.94Drug product containers and closures1 of 5
- 21 CFR 211.111Time limitations on production1 of 5
- 21 CFR 211.160General requirements1 of 5
- 21 CFR 211.167Special testing requirements1 of 5
- 21 CFR 211.198Complaint files1 of 5
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3009724085 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3009724085. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.