OPS International Inc dba Olympia Pharmaceuticals Form 483, September 2026
FDA issued this Form 483 to OPS International Inc dba Olympia Pharmaceuticals in Florida (FEI 3009724085) at the end of an inspection that ended September 3, 2026. It lists 8 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 1, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Sep 3, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Oct 1, 2026
- 28 days after the inspection
The 8 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Deficient aseptic environmental monitoring system
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, (A) The firm's environmental monitoring procedure does not require viable environmental monitoring during the initial aseptic setup of the (b)(4) filling line within the (b)(4) or during the initial aseptic setup of the (b)(4) automated filling machine positioned under [illegible] HEPA-filtered unidirectional airflow enclosure. Per SOP-009, Environmental Monitoring of the Controlled Production Areas, environmental monitoring is not required to commence until aseptic connections setup activities have occurred. (1) On August 26, 2026, we observed operator performing set-up of the (b)(4) for the (b)(4) automated filling machine (Equipment ID #(b)(4)) for the filling of Calcium Chloride (Lot #H24A01-26). No environmental monitoring plates were present within the ISO 5 critical area under the (b)(4) unidirectional airflow unit during this setup activity. (2) According to the batch record for Myer's Cocktail (Lot #G27A05-26, Exp. 26 Nov 2026), equipment set-up of the (b)(4) auto filler, located inside the ISO (b)(4) in Suite (b)(4) began at 08:01. The first passive air sample was not opened until 08:21 on 30 July 2026. (B) The firm's personnel monitoring program does not include microbiological monitoring of gown locations for Sterile Techs who perform set-up of the (b)(4) filling line or set-up of the (b)(4) automated filling machine. Gown monitoring at a defined schedule, supported by scientific justification, is not included in the program. (1) On August 21, 2026, we observed Sterile Tech performing line setup for the filling of Biotin 0.5 mg/mL (Lot #H17A05-26) with his head, body, and sleeves inside the ISO 5 (b)(4) chamber without any concurrent personnel monitoring. (2) On August 26, 2026, we observed Sterile Tech performing set up for the filling of Calcium Chloride (Lot #H24A01-26) with his sleeves inside the ISO 5 (b)(4) HEPA-filtered unidirectional airflow enclosure (LAFW-(b)(4)). The (b)(4) automated (b)(4) filling machine operates under (b)(4) HEPA-filtered unidirectional airflow enclosure with no physical barrier between the filling operation and the operator. (C) Gloved fingertip monitoring of the Sterile Tech is performed only following completion of the aseptic filling production shift.
- 2
Inadequate sterile contamination prevention procedures
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. Specifically, (A) Your firm has not adequately demonstrated that (b)(4)-sterilized machine (b)(4) parts and accessories used in aseptic filling maintain their sterile state during the established (b)(4) sterilization hold time in a controlled, non-classified area. The supporting microbiological evaluation consisted of swabbing part surfaces and incubating samples in (b)(4) medium at (b)(4) for (b)(4). (1) Your firm has not provided adequate scientific justification that these incubation conditions are suitable for recovering and detecting microorganisms that may be encountered if the sterile barrier is compromised during storage within the non-classified area. (2) The provided record associated with the sampling, in-house incubation, and results of the swab samples lacked the following critical information: Actual incubation temperature; Date and time samples were placed in the incubator; Date and time samples were removed from the incubator; Identity of the person who read the results. (3) According to your Senior Quality Manager and Senior Director of Compliance, following the in-house incubation of the swab samples, the samples were sent to your contract laboratory for sterility testing; however, the associated records, including the third-party sterility test results, could not be located. (B) On August 21, 2026, during aseptic setup of the (b)(4) filling line for Biotin 0.5 mg/mL (Lot #H17A05-26), [illegible] Chamber (Material Chamber) (b)(4) surfaces to the ISO 7 environment. Subsequently the (b)(4) were [illegible] without disinfecting the exposed (b)(4) surfaces, thereby reintroducing ISO 7 environmentally exposed surfaces into the ISO 5 critical area. (C) Your firm has not adequately established a visual inspector qualification program to demonstrate that personnel can consistently and reliably detect microbial growth during the visual inspection of media-filled units. (1) Your challenge qualification [illegible] contain (b)(4) prepared with (b)(4) in (b)(4) vials and (b)(4). Your firm has no documented scientific justification for the use of (b)(4) as a surrogate for actual microbial contamination/turbidity. (2) There is no documented justification for the number, type, and distribution of positive units to demonstrate reliable contamination detection in media fills filled in (b)(4) vials. (3) (b)(4) vials are used to simulate your (b)(4) mL and (b)(4) mL vialing process during aseptic process simulation (APS). You have not evaluated whether turbidity can be adequately detected in these vials. (D) Your 2026 smoke studies, conducted as per PRO-029-01, Smoke Study Protocol, and PRO-029-03, (b)(4) Airflow Visualization Protocol, did not adequately qualify unidirectional airflow or demonstrate first air and acceptable airflow patterns during critical operations. For example: (1) Airflow patterns could not be adequately assessed in multiple (b)(4) chambers and the (b)(4) HEPA-filtered unidirectional airflow unit due to obstructions, glare, inadequate smoke introduction technique, and/or camera angle limitations (e.g. (b)(4) Chamber video; (b)(4) video). (2) In (b)(4) Chamber turbulent eddies were observed near a (b)(4) (~3:26-4:22), and smoke was observed exiting and briefly re-entering the chamber near the top when the (b)(4) were (b)(4) during setup (video time point: ~4:40-4:55). (3) The studies simulated routine activities, including line setup, loading of vials, stoppers and caps, and cleaning; however, the only corrective intervention evaluated was removal of a vial from the filling line using [illegible]. Your firm did not provide an adequate assessment demonstrating that the interventions selected represent reasonably foreseeable corrective interventions and worst-case aseptic manipulations during production. The affected equipment includes: (b)(4) in Suite (b)(4) housing the (b)
Shortened here; the PDF has the full text.
- 3
Production procedures not followed and documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance. Specifically, (B) Batch record review of Myer's Cocktail (Lot #G27A05-26, Exp. 26 Nov 2026) revealed that equipment set-up of the (b)(4) filling line, located inside the ISO 5 (b)(4) in Suite (b)(4) began on 30 July 2026 at 08:01 and was completed by Sterile Tech at 08:06 on 30 July 2026 — a total elapsed time of five minutes. However, set-up encompassed installation of (b)(4) chambers: (b)(4) where each require multiple set up steps. For example, the (b)(4) chamber alone required the installation of multiple components, including the (b)(4), and other associated parts. (C) Visual inspectors did not perform [illegible] via (b)(4) as required by Section 9.3 of SOP-007, Visual Inspection of Sterile Drug Products, and inspection steps performed in practice differed from those written in the procedure. (1) On August 20, 2026, Sterile Tech was observed conducting visual inspection of Amino Blend (Lot #H11A03-26) and failed to perform vial (b)(4). When subsequently asked to describe the inspection procedure, Sterile Tech was again unable to identify vial (b)(4) as a required step. (2) On August 21, 2026, Sterile Tech was observed performing visual inspection of Biotin 0.5 mg/mL (Lot #H17A05-26) and similarly failed to perform vial (b)(4). (D) On September 1, 2026, the (b)(4) (Equipment ID: (b)(4)) was observed loaded with [illegible] on (b)(4) on August 28, 2026. Notably, the (b)(4) was loaded with (b)(4); however, your currently approved procedure, SOA-040-01, Sterilization Load Configurations, effective 05 June 2026, specifies a (b)(4) load pattern diagram of only (b)(4).
- 4
Inadequate visual inspection qualification procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, the (b)(4) visual inspection qualification (b)(4) used to qualify personnel performing 100% visual inspection of injectable drug products are not adequately characterized or designed to challenge inspectors' ability to detect particulates at or near the threshold of visual detectability. For example: (A) Your firm has not established the size or size range of the particulate defects contained in the qualification units intended to challenge visual inspectors to detect the smallest contaminants possible for an inspector with 20/20 vision. Although (b)(4) defect vials containing particulates were submitted for size characterization, the analysis was performed using the particle-size distribution method described in USP <429>, as documented in the Certificates of Analysis. The resulting data do not establish the size of the individual particulate defect contained in each qualification unit. (B) No written procedures or records exist documenting the preparation and contents of each particulate defect unit, including particulate type, size or size range, and method of preparation. This information is known only to the individual who prepared the qualification (b)(4).
- 5
Stability program lacks stability-indicating methods
The written stability program for drug products does not include reliable, meaningful and specific test methods. Specifically, your firm assigns a (b)(4) beyond-use date (BUD) to Sermorelin Acetate 0.9 mg/mL Injection based on your contract laboratory stability study. However, your firm failed to provide adequate demonstration that the analytical procedure can detect relevant degradation-related changes. Your method validation report for Sermorelin Acetate, approved on August 22, 2025, does not include a mass balance assessment to demonstrate that the analytical method can adequately account for the drug substance and its degradation products, supporting the method's stability-indicating capability and reliability.
- 6
Deficient segregation for sterilized parts storage
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. Specifically, (A) Your firm utilizes (b)(4) QA-access-controlled cabinets for the storage of sterilized machine (b)(4) parts and accessories. During inspection of these cabinets (b)(4) components, including a stopper bowl that directly contacts product stoppers, were observed without sterilization-status labels. The components lacked information identifying the applicable (b)(4) and sterilization date needed for personnel to determine whether the established sterile hold time had been exceeded. (B) Sterilization-status labels are generated by operators; however, the firm did not demonstrate a system for reconciling generated labels to the individual equipment parts associated with each sterilization cycle.
- 7
Deficient component sampling and testing
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality. Specifically, (A) SOP-035, Procurement, Receipt, and Inspection of Incoming Components and Materials, does not include a sampling plan specifying the number of containers to be sampled per shipment. According to the Senior Supply Chain Manager, (b)(4) sent from your (b)(4) warehouse to your facility for sampling. Additionally, no documentation exists for the sampling performed. (B) Your firm failed to perform a specific identity test that includes a methanol limit test on each container of each lot of ethyl alcohol used as a pharmaceutical ingredient. On May 12, 2025, your firm received, sampled, and [illegible] bottles of (b)(4) Ethyl Alcohol (b)(4) Proof (Batch #(b)(4)); (b)(4) methanol limit testing was not performed. This lot was used in the production of T-105 Injection (Papaverine Hydrochloride 30 mg/mL; Phentolamine Mesylate 1 mg/mL; Alprostadil 0.01 mg/mL), Lot #G08A10-26, BUD 04 JUL 2027. (C) Your firm failed to test each container of each lot of glycerin, used as a pharmaceutical ingredient, for diethylene glycol (DEG) or ethylene glycol (EG) contamination. Your firm did not provide a scientifically sound justification, supported by statistical analysis, for reduced sampling. On September 25, 2025, your firm received (b)(4) bottles of (b)(4) Glycerin, NF (b)(4) (Lot #(b)(4)); however, (b)(4) sampled and tested for this shipment. Additionally, Lot #(b)(4) was tested only for Identification A and was not tested for DEG and EG prior to release for use. This lot was used in the production of Glycerin 48% / Lidocaine 0.33% Injection (Lot #E20A10-26; BUD 10 JAN 2027).
- 8
Batch additions lack second-person verification
Each component is not added to the batch by one person and verified by a second person. Specifically, a review of the batch record for Myer's Cocktail (Lot #(b)(4), Exp. (b)(4)) revealed that ingredients were added between (b)(4) on July 29, 2026, with no documented contemporaneous verification recorded after each individual addition. Instead, a single verification timestamp of (b)(4) was documented for this manufacturing step, more than two hours after the last ingredient was added.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3009724085, newest first.
- Form 483, August 2025Inspection ended Aug 8, 2025 · Posted Sep 12, 2025OAI
- Form 483, May 2024Inspection ended May 29, 2024 · Posted Aug 6, 2024OAI
- Form 483, March 2022FDA record date Mar 2, 2022 · Posted Sep 26, 2022
- Form 483, April 2018Inspection ended Apr 13, 2018 · Posted Jan 17, 2024VAI
- Form 483, March 2013Inspection ended Mar 21, 2013 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.