Skip to content

21 CFR 211.42: Design and construction features

FDA's inspection data lists 1,661 Form 483 citations of 21 CFR 211.42 at 826 facilities, from November 2008 to September 16, 2026. 81 warning letters state a violation of it.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
1,661
At 1,071 inspections
Facilities cited
826
Distinct FEIs
Most recent citation
Sep 16, 2026
Coty US LLC
Warning letters
81
State a violation of it

The regulation

The current text of 21 CFR 211.42 from the Electronic Code of Federal Regulations.

§ 211.42 Design and construction features.

(a) Any building or buildings used in the manufacture, processing, packing, or holding of a drug product shall be of suitable size, construction and location to facilitate cleaning, maintenance, and proper operations.

(b) Any such building shall have adequate space for the orderly placement of equipment and materials to prevent mixups between different components, drug product containers, closures, labeling, in-process materials, or drug products, and to prevent contamination. The flow of components, drug product containers, closures, labeling, in-process materials, and drug products through the building or buildings shall be designed to prevent contamination.

(c) Operations shall be performed within specifically defined areas of adequate size. There shall be separate or defined areas or such other control systems for the firm's operations as are necessary to prevent contamination or mixups during the course of the following procedures:

(1) Receipt, identification, storage, and withholding from use of components, drug product containers, closures, and labeling, pending the appropriate sampling, testing, or examination by the quality control unit before release for manufacturing or packaging;

(2) Holding rejected components, drug product containers, closures, and labeling before disposition;

(3) Storage of released components, drug product containers, closures, and labeling;

(4) Storage of in-process materials;

(5) Manufacturing and processing operations;

(6) Packaging and labeling operations;

(7) Quarantine storage before release of drug products;

(8) Storage of drug products after release;

(9) Control and laboratory operations;

(10) Aseptic processing, which includes as appropriate:

(i) Floors, walls, and ceilings of smooth, hard surfaces that are easily cleanable;

(ii) Temperature and humidity controls;

(iii) An air supply filtered through high-efficiency particulate air filters under positive pressure, regardless of whether flow is laminar or nonlaminar;

(iv) A system for monitoring environmental conditions;

(v) A system for cleaning and disinfecting the room and equipment to produce aseptic conditions;

(vi) A system for maintaining any equipment used to control the aseptic conditions.

(d) Operations relating to the manufacture, processing, and packing of penicillin shall be performed in facilities separate from those used for other drug products for human use.

21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart CRead on eCFR

Citations by year

Form 483 citations of 21 CFR 211.42 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 213 in 2015

Form 483 citations of 21 CFR 211.42 by inspection year
YearForm 483 citations
20081
200945
201053
201171
201234
2013113
2014134
2015213
2016155
2017110
2018121
2019127
202019
202167
202282
202380
202494
202585
202657

How FDA words this citation

FDA's short descriptions and citation text on these 1,661 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Environmental Monitoring System455 citations
  • Cleaning System316 citations
  • Defined areas of adequate size for operations183 citations
  • Buildings of Suitable Size, Construction, Location144 citations
  • Air Supply94 citations
Show 3 more
  • Equipment to control conditions90 citations
  • Aseptic Processing Area72 citations
  • Adequate space lacking to prevent mix-ups and contamination52 citations

Citation text

  • “Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.”455 citations
  • “Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.”214 citations
  • “Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.”94 citations
  • “Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.”90 citations
Show 2 more
  • “Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.”88 citations
  • “The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.”78 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 211.42, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Show 4 more

What the observations say

Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.42 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 162 observations tie this way. The highlighted sentence is the matched wording.

  • Apollo Care, LLC2025-03-27 · Observation 5

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, A) On 03/18/2025, I observed an unsealed and loose ceiling tile within the ISO [illegible] of non-sterile bulk drug solution in the ISO 5 hood, Phenylephrine HCL 100 mcg/mL, Lot [illegible]. During setup the tile lifted, exposing the room to a lesser quality air that bypassed HEPA filtration. Operator …

    This observation opens with FDA's standard wording for 21 CFR 211.42(c)(10)(vi).FDA also lists this citation for this inspection.

  • Glenmark Pharmaceuticals Limited2025-02-14 · Observation 2

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Separate or defined areas to prevent contamination are deficient re (bf(\.l ,.l.. mg products (CbH Tablets) at your facility. For example: A. You failed to ensure sampling, dispensing, [and] [illegible] for (6) (CbH Tablets) are carried out using dedicated [illegible] systems. For example: • Sampling areas, …

    This observation opens with FDA's standard wording for 21 CFR 211.42(c)(5).FDA also lists this citation for this inspection.

  • Nubratori, Inc2024-07-26 · Observation 2

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, On 07/17/2024, during the production of Lidocaine HCl/Tetracaine HCl (Lot#[(6 ) I observed that the technician collect their glove fingertip personnel monitoring samples, after wiping a piece sampling equipment with Sterile[(b) (4)], and samples were not taken immediately after completion of aseptic operations. Personnel monitoring …

    This observation opens with FDA's standard wording for 21 CFR 211.42(c)(10)(iv).FDA also lists this citation for this inspection.

Show 2 more
  • OPS International Inc dba Olympia Pharmaceuticals2026-09-03 · Observation 1

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, (A) The firm's environmental monitoring procedure does not require viable environmental monitoring during the initial aseptic setup of the (b)(4) filling line within the (b)(4) or during the initial aseptic setup of the (b)(4) automated filling machine positioned under [illegible] HEPA-filtered unidirectional airflow enclosure. Per …

    This observation opens with FDA's standard wording for 21 CFR 211.42(c)(10)(iv).

  • RC Outsourcing LLC2026-09-03 · Observation 3

    Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Specifically, A. Personnel and material flow into and out of the ISO 7 and ISO 8 classified areas occurs through a single shared pathway that passes directly through the visual inspection and labeling room. Gowning, degowning, and material transfer — including finished product exiting the cleanroom and incoming …

    This observation opens with FDA's standard wording for 21 CFR 211.42(c)(5).

Warning letters stating a violation of 21 CFR 211.42

81 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.

“Your firm failed to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups. Your firm also failed to use equipment in the manufacture, processing, packing, or holding of drug products that is of appropriate design, adequate size, and suitably located to facilitate operations for its intended use and for its cleaning and maintenance. (21 CFR 211.42(c) and 21 CFR 211.63).”
“Your firm failed to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups (21 CFR 211.42(c)), and your firm failed to establish and follow adequate control procedures to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product (21 CFR 211.110(a)).”
“Your firm failed to perform operations within specifically defined areas of adequate size and to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups (21 CFR 211.42(c)).”
“Your firm failed to establish adequate control procedures to monitor the output and to validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug. Your firm failed to perform operations within specifically defined areas of adequate size and to have separate or defined areas or such other control systems necessary to prevent contamination or mix-ups in aseptic processing areas (21 CFR 211.110(a) and 21 CFR 211.42(c)(10)).”
“Your firm failed to establish an adequate system for maintaining equipment used to control the aseptic conditions (21 CFR 211.42(c)(10)(vi)).”
“Your firm failed to establish an adequate air supply filtered through high-efficiency particulate air filters under positive pressure in the aseptic processing areas (21 CFR 211.42(c)(10)(iii)).”

Often cited at the same inspection

Of the 1,071 inspections where FDA cited 21 CFR 211.42, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 211.42

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

Topics that count this section:Aseptic processing

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.42; FDAgent quotes that sentence exactly.