FDA has 7 inspections on file for RC Outsourcing LLC in Ohio (FEI 3011967886), from 2016 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Aug 28, 2025. FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.
Eight regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 7, 2016–2026
- 4 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 7 of 7
- 3 posted 483s not matched to an inspection
- Requested under FOIA
- 1 request, latest Apr 28, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetClassification not posted yetPosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate validation of aseptic and sterilization process
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. Specifically, A. Your firm conducted Airflow Visualization (AFV) studies (smoke studies) for ISO 5 Laminar Flow Hood (LFH) and Laminar Flow Hood (LFH) under both static and dynamic conditions in August 2025 and February 2026. No formal study reports or supporting documentation were available for review for either study. The records lacked the following critical study elements: the type of smoke sources, the stated study purpose, targeted test locations, and personnel activities performed during dynamic conditions, real-time observations, and conclusions. Although video recordings of the AFV studies were captured, they were not accompanied by written protocols, contemporaneous documentation, or summary reports sufficient to contextualize, interpret, or substantiate the visual findings. B. Discrepancies were identified in the Airflow Visualization (AFV) records (videos) for ISO 5 Laminar Flow Hood (LFH) and Laminar Flow Hood (LFH) from studies completed in August 2025 and February 2026. The following deficiencies were observed: i. Incomplete Coverage of Critical Production Steps. Across both August 2025 and February 2026 AFV studies, the dynamic airflow visualization did not encompass all critical steps performed during commercial production operations. For example, the following steps were not captured in either study period: needle, syringe preparation, cap preparation, opening of syringe and cap boxes (trays of (b)(4) units), drawing drug product from vials into a mL syringe using (b)(4), picking up and attaching caps to filled syringes, and the capping process. Only the filling of each mL syringe to the 0.07 mL mark was consistently captured. This deficiency was observed across multiple video records. ii. Stationary Fogger Wand and Absence of Airflow Visualization Over Critical Work Zones. In multiple video records from February 2026, the fogger wand was held stationary rather than maneuvered to cover all critical work surfaces and product-contact areas. For example: In the provided video (LFH Repacking, dynamic), no airflow visualization was observed over the syringe to be filled or cap containers from T=[illegible] to T=[illegible] and no AFV was observed over the filling area at T=[illegible]. In the provided video (LFH Sterile, dynamic), the fogger wand was stationary, and no airflow visualization was captured over the initial collection of drug product from the (b)(4) container into the syringe (T=[illegible] to T=[illegible]). In the provided video (LFH, Repacking, dynamic), the fogger wand remained stationary throughout the entire video, with no airflow visualization captured over the syringe and cap containers at any point during the study. iii. Absence of AFV During Dynamic (Operational) Conditions. In the provided video (LFH) (February 2026), airflow visualization was observed only under static conditions (T=[illegible] to T=[illegible]). Once the operator began preparation for production, no AFV was conducted during the dynamic phase (T=[illegible] to T=[illegible]), despite dynamic studies being required to reflect actual operational conditions. iv. Absence of Active Air Sampling During AFV Studies. In all three August 2025 video records covering both LFH and LFH, no active air sampling was performed concurrent with the AFV studies. Active air sampling during AFV studies is necessary to assess and document the microbiological quality of the environment under simulated or actual operational conditions. The AFV studies for ISO 5 LFH and LFH conducted in both August 2025 and February 2026, were incomplete and did not adequately simulate or represent actual commercial production operations, including critical manual steps and interventions. These deficiencies indicate that unidirectional airflow protection over open product and product-con
Shortened here; the PDF has the full text.
- Observation 2
Inadequate sterility failure investigations and batch review
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Sterility test failure investigations for aseptically re-packaged Avastin 1.25 mg/0.05 mL were inadequate and failed to identify probable root causes. Since October 2025, the firm has rejected four batches due to sterility failures. Despite the rejection of these batches, other batches manufactured on the same day and in the same laminar flow hood in the table below were released without a scientifically sound justification or supporting data demonstrating adequate risk mitigation. Fill date: 10/17/2025 Rejected lot # 20251017-6D87A8 Released lot manufactured in the 2nd hood 20251017-01A42E Released lots manufactured in the same hood 20251017-0FFE8B, 20251017-03F240, 20251017-235C2A. Fill date: 10/21/2025 Rejected lot 20251021-01F7A1 Released lot manufactured in the 2nd hood 20251021-8CC0D9 Released lots manufactured in the same hood 20251021-1BEBE6, 20251021-5C30B4, 20251021-817D6D. Fill date: 3/09/2026 Rejected lot 20260309-8FE1A0 Released lot manufactured in the 2nd hood 20260309-141A33 Released lots manufactured in the same hood 20260309-3645AC, 20260309-80AC52. Fill date: 6/15/2026 Rejected lot 20260615-4D607D Released lot manufactured in the 2nd hood 20260615-812D57 Released lots manufactured in the same hood 20260615-7E9720, 20260615-42D2D3. Your firm's failure to identify probable root causes for sterility test failures raises significant concerns regarding the robustness of the aseptic filling operations and the integrity of the contamination control strategy. The release of concurrent batches — manufactured under the same conditions as the rejected lots without adequate scientific justification or documented risk mitigation poses a direct risk to patient safety, as those products may not meet sterility assurance requirements.
Show observations 3 to 8
- Observation 3
Deficient separate areas to prevent contamination
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations. Specifically, A. Personnel and material flow into and out of the ISO 7 and ISO 8 classified areas occurs through a single shared pathway that passes directly through the visual inspection and labeling room. Gowning, degowning, and material transfer — including finished product exiting the cleanroom and incoming components entering — all traverse the same corridor used for labeling and visual inspection of previously released product, creating a convergence of traffic that is inconsistent with unidirectional flow principles. Specifically, operators completing shoe covers, head covers, masks, and hand washing in the non-classified area must traverse this shared labeling room pathway to reach the ISO 8 entry door. Upon degowning, operators must similarly walk from ISO 7, through ISO 8, and through this same labeling room, where other staff are actively performing packaging, labeling, and visual inspection activities, to reach an outside corridor. No designated degowning area exists within the ISO 8 anteroom. Additionally, no physical or spatial separation exists within the ISO 8 anteroom to support or delineate a gowning zone, and operators were observed leaning against ISO 8 walls and tables for stability during gowning, introducing a potential source of contamination to sterile garments. B. Within this same access route, a door handle providing passage between the ISO 7 and ISO 8 classified areas and the labeling room was observed to be visibly degraded due to repeated exposure to cleaning and disinfecting agents. Furthermore, the curved geometry of the handle prevents adequate cleaning and disinfection of all contact surfaces. C. Airflow vents in the ISO 7 cleanroom and ISO 8 anteroom are obstructed. For example, multiple items — including storage containers, a table, and (b)(4) bottles — were observed blocking the air vents in the ISO 8 anteroom. The shared personnel and material pathway through the visual inspection and labeling room, the absence of a designated gowning and degowning zone, a deteriorating and inadequately cleanable door handle, and obstructed airflow vents collectively represent significant deficiencies in contamination control infrastructure. These conditions compromise the environmental integrity of the ISO 7 and ISO 8 classified areas and present a risk of cross-contamination to finished product, released materials, and ongoing sterile production operations.
- Observation 4
Lack of adequate written sanitation procedures
There is a lack of written procedures assigning responsibility, providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation. Specifically, A. Your firm's cleaning procedure is inadequate. i. Your firm stated that only the ISO 5 laminar flow hood receives cleaning (b)(4). However, your firm failed to clean the ISO 7 classified area (b)(4) leaving cleaning to the end of production for the day. ii. Your firm lacks scientifically established and data-supported cleaning intervals for the cleanroom. A review of cleaning records revealed a 49-day gap between the deep cleaning performed on 02/09/2026 and the subsequent cleaning on 03/30/2026. Furthermore, your firm acknowledged that scheduling cleaning on a (b)(4) basis — rather than at fixed intervals — could permit up to (b)(4) between cleaning events. Cleaning intervals of this duration, without scientific justification or validated hold-time data, present an unacceptable risk of microbial proliferation and environmental contamination in a classified cleanroom, potentially compromising the sterility and quality of drug products manufactured therein.
- Observation 5
No temperature mapping under worst-case conditions
Routine calibration, inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance. Specifically, Your firm has not performed temperature mapping under the worst-case conditions for your critical equipment during equipment qualification. For example, your firm operates incubators (b)(4); and (b)(4) refrigerators (b)(4), all of which are used for product storage and environmental monitoring (EM) sample incubation. A review of the initial qualification records for these units revealed that temperature mapping was performed exclusively under empty-state conditions. When asked whether temperature mapping under operationally loaded conditions had been performed to reflect the units' current operational use, your firm confirmed that only the initial empty-state mapping had been completed and no subsequent studies have been initiated.
- Observation 6
Unjustified subvisible particle specifications for Avastin
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm continues to fail to provide a scientific rationale to support the established method and limits for subvisible particle testing of Avastin (bevacizumab) 1.75 mg/0.07 mL for intravitreal injection. Your firm releases this product using a subvisible particulate matter specification of (b)(4) particles/container at (b)(4) um and (b)(4) particles/container at (b)(4) um. All lots associated with endophthalmitis adverse events were released using this particulate matter specification. This observation is a repeat observation from the previous FDA 483, List of Observations, issued on 11/04/2024.
- Observation 7
Employees not given required GMP training
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations. Specifically, A. Your firm does not conduct periodic CGMP training for employees. B. Not all personnel receive basic training on the theory and practice of the Quality Management System and Good Manufacturing Practices, as required, per SOP-6 Training and Personnel, v2.0, effective September 30, 2025, Section 5.2.1. C. Your firm has not established training or qualification requirements to ensure that personnel responsible for reading and interpreting EM plate results are able to accurately enumerate and differentiate microbial growth and surface colonization.
- Observation 8
Expiration dates unsupported by stability studies
Drug product expiration dates are not related to the storage conditions stated on the labeling, as determined by stability studies. Specifically, Your firm's product labels do not specify required storage temperature conditions, and the assigned beyond-use date (BUD) is not supported by stability testing. For example: your firm has failed to specify required storage temperature conditions on product labels, despite assigning a beyond-use date (BUD). For example, your firm stated that stability testing is not conducted for its non-sterile compounded products on the basis that the water activity content is less than [illegible]%, with a BUD assigned at a controlled room temperature of [illegible]. However, all three non-sterile product labels reviewed during the inspection indicated only "room temperature," without further qualification or specification of the required temperature range, which is inconsistent with your firm's stated storage conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Calibration/Inspection/Checking not done
Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Show 3 more citations
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Reserve samples identified, representative, stored
Reserve drug product samples are not appropriately identified and representative of each lot or batch of drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that conform to appropriate standards of identity, strength, quality and purity.
Show 3 more citations
Quality Control Review
Complaint procedures are deficient in that they do not include provisions that allow for the review and determination of an investigation by the quality control unit.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Product flow through building is inadequate
The flow of components, drug product containers, closures, in-process materials and drug products through the building is not designed to prevent contamination.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.
Show 4 more citations
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Calibration/Inspection/Checking not done
Routine of equipment is not performed according to a written program designed to assure proper performance.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to follow process procedures
Written production and process control procedures are not followed in the execution of production and process control functions. Specifically, a. Your firm failed to follow the formula worksheet for the compounding of Vancomycin HCl USP 1 mg/0.1 ml lot no. 03092018. Per the worksheet instructions the specified pH range should be [(b) (4 )] however the reported pH value for this lot was 6.97. This lot was associated with two complaints your firm received on 4/2/18 for cloudiness in the drug after thawing. Your firm's investigation into these complaints attributed the observed cloudiness to vancomycin precipitating out of solution from the high pH value observed during production. b. Your firm's Quality review failed to observe this pH OOS event prior to lot release on 3/9/18. c. You did not implement adequate CAPA's to address the failure of your firm's quality unit to observe this pH OOS event.
- Observation 2
No written stability testing program
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, Your firm has not provided adequate data in the form of published literature or test studies which support the BUD/Expiration dates for products produced.
Show observations 3 to 8
- Observation 3
Failure to investigate syringe defects
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, Your firm failed to conduct an investigation for the 70 syringe defect complaints your firm received between April 1, 2017 and December 31, 2018. Syringe defect categories included: - bent needle - dull needle - clogged needle - stuck plunger - empty syringe
- Observation 4
Inadequate identity/strength and sterility testing
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. Specifically, Your firm did not conduct identity and strength (potency) testing of each lot for the following drug products produced at your facility: - Cefuroxime 1 mg - Moxifloxacin 1.5 mg - Vancomycin 1 mg - Vancomycin 2 mg In addition, the following tests were also observed not having been performed: Testing for pH of each lot was not performed for the following sterile injectable drug product produced at your facility: - Cefuroxime 1 mg Testing for subvisible particulate of each lot was not performed for the following sterile injectable drug products produced at your facility: - Cefuroxime 1 mg - Moxifloxacin 1.5 mg - Vancomycin 1 mg - Vancomycin 2 mg Sterility testing of each lot was not performed for the following sterile drug products produced at your facility: - Cefuroxime 1 mg - Moxifloxacin 1.5 mg - Vancomycin 1 mg - Vancomycin 2 mg ***THIS IS A REPEAT OBSERVATION***
- Observation 5
Unverified/undocumented test methods
The accuracy, sensitivity and reproducibility of test methods have not been established and documented. Specifically, Your firm's process for conducting the in-house sterility test has not been verified as being suitable for its intended use in the sterility testing of Dexamethasone 400mcg, Lidocaine 1%, Phenylephrine 1.5%, Phenylephrine 2.5%. Further, the in-house sterility testing process is not detailed in a formal procedure.
- Observation 6
Inadequate environmental monitoring
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, Active air sampling is not performed daily during production activities. **THIS IS A REPEAT OBSERVATION***
- Observation 7
No identity testing of incoming APIs
Specific identification tests are not conducted on components that have been accepted based on the suppliers report of analysis. Specifically, Your firm does not perform an identity test on all incoming lots of bulk active pharmaceutical ingredients (APIs). The following bulk APIs are used in the production of drug products at your facility: - Moxifloxacin Hydrochloride USP - Dexamethasone Sodium Phosphate USP - Tobramycin Sulfate USP - Phenylephrine Hydrochloride USP - Vancomycin Hydrochloride USP
- Observation 8
Compounding copies of approved drugs
You compound drugs that are essentially a copy of one or more approved drugs within the meaning of sections 503B(a)(5) and 503B(d)(2). Specifically, you compound drug products that: a) are identical or nearly identical to an approved drug that is not on the drug shortage list in effect under section 506E at the time of compounding, distribution, and dispensing; or b) are not identical or nearly identical to an approved drug, but contain a bulk drug substance that is also a component of an approved drug, and for which there is no change that produces for an individual patient a clinical difference, as determined by the prescribing practitioner, between the compounded drug and the comparable approved drug. Examples of compounded drug products that are essentially a copy of one or more approved drugs include; - Dexamethasone 400 mcg/0.1 mL syringe for injection - Moxifloxacin 0.150 mg/0.1 mL syringe for injection - Vancomycin 1 mg/0.1 mL syringe for injection - Vancomycin 2 mg/0.1 mL syringe for injection - Vancomycin 25 mg/mL - 10 mL dropper
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing, processing and packing of drug products is not appropriate for the duties they perform.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Test methods
The accuracy and reproducibility of test methods have not been established and documented.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Show 4 more citations
Sterility/pyrogens - test methods written, followed
Test procedures relative to appropriate laboratory testing for sterility are not followed.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be pyrogen-free is not laboratory tested to determine conformance to such requirements.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed .
Calibration/Inspection/Checking not done
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Show 3 more citations
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
Complaints
Complaint files are not maintained. Specifically ***
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility?s drug products are deficient.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Apr 28, 2026. It asked for a Form 483.
Inspection ending Aug 28, 2025OAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Apr 28, 2026FDA-FOIA-2026-4204Form 483Withdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.42Design and construction features5 of 5
- 21 CFR 211.113Control of microbiological contamination5 of 5
- 21 CFR 211.192Production record review5 of 5
- 21 CFR 211.68Automatic, mechanical, and electronic equipment3 of 5
- 21 CFR 211.160General requirements3 of 5
- 21 CFR 211.28Personnel responsibilities2 of 5
- 21 CFR 211.100Written procedures; deviations2 of 5
- 21 CFR 211.167Special testing requirements2 of 5
Show all 16
- 21 CFR 211.22Responsibilities of quality control unit1 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 5
- 21 CFR 211.165Testing and release for distribution1 of 5
- 21 CFR 211.170Reserve samples1 of 5
- 21 CFR 211.188Batch production and control records1 of 5
- 21 CFR 211.194Laboratory records1 of 5
- 21 CFR 211.198Complaint files1 of 5
- 21 CFR 820.198Complaint files1 of 5
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011967886 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011967886. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.