21 CFR 211.194: Laboratory records
FDA's inspection data lists 1,196 Form 483 citations of 21 CFR 211.194 at 811 facilities, from November 2008 to August 25, 2026. 32 warning letters state a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 1,196
- At 984 inspections
- Facilities cited
- 811
- Distinct FEIs
- Most recent citation
- Aug 25, 2026
- Mylan Laboratories Limited (FDF-2)
- Warning letters
- 32
- State a violation of it
The regulation
The current text of 21 CFR 211.194 from the Electronic Code of Federal Regulations.
§ 211.194 Laboratory records.
(a) Laboratory records shall include complete data derived from all tests necessary to assure compliance with established specifications and standards, including examinations and assays, as follows:
(1) A description of the sample received for testing with identification of source (that is, location from where sample was obtained), quantity, lot number or other distinctive code, date sample was taken, and date sample was received for testing.
(2) A statement of each method used in the testing of the sample. The statement shall indicate the location of data that establish that the methods used in the testing of the sample meet proper standards of accuracy and reliability as applied to the product tested. (If the method employed is in the current revision of the United States Pharmacopeia, National Formulary, AOAC INTERNATIONAL, Book of Methods, 1 or in other recognized standard references, or is detailed in an approved new drug application and the referenced method is not modified, a statement indicating the method and reference will suffice). The suitability of all testing methods used shall be verified under actual conditions of use.
1 Copies may be obtained from: AOAC INTERNATIONAL, 481 North Frederick Ave., suite 500, Gaithersburg, MD 20877.
(3) A statement of the weight or measure of sample used for each test, where appropriate.
(4) A complete record of all data secured in the course of each test, including all graphs, charts, and spectra from laboratory instrumentation, properly identified to show the specific component, drug product container, closure, in-process material, or drug product, and lot tested.
(5) A record of all calculations performed in connection with the test, including units of measure, conversion factors, and equivalency factors.
(6) A statement of the results of tests and how the results compare with established standards of identity, strength, quality, and purity for the component, drug product container, closure, in-process material, or drug product tested.
(7) The initials or signature of the person who performs each test and the date(s) the tests were performed.
(8) The initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
(b) Complete records shall be maintained of any modification of an established method employed in testing. Such records shall include the reason for the modification and data to verify that the modification produced results that are at least as accurate and reliable for the material being tested as the established method.
(c) Complete records shall be maintained of any testing and standardization of laboratory reference standards, reagents, and standard solutions.
(d) Complete records shall be maintained of the periodic calibration of laboratory instruments, apparatus, gauges, and recording devices required by § 211.160(b)(4).
(e) Complete records shall be maintained of all stability testing performed in accordance with § 211.166.
21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart JRead on eCFR
Citations by year
Form 483 citations of 21 CFR 211.194 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 111 in 2010
| Year | Form 483 citations |
|---|---|
| 2008 | 11 |
| 2009 | 66 |
| 2010 | 111 |
| 2011 | 82 |
| 2012 | 92 |
| 2013 | 49 |
| 2014 | 65 |
| 2015 | 71 |
| 2016 | 80 |
| 2017 | 111 |
| 2018 | 100 |
| 2019 | 76 |
| 2020 | 20 |
| 2021 | 38 |
| 2022 | 38 |
| 2023 | 47 |
| 2024 | 39 |
| 2025 | 69 |
| 2026 | 31 |
How FDA words this citation
FDA's short descriptions and citation text on these 1,196 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Complete test data included in records330 citations
- Second person sign off192 citations
- Complete Test Data122 citations
- Suitability of testing methods verified78 citations
- Laboratory equipment calibration records71 citations
Show 3 more
- Testing and standardization of standards et. al.69 citations
- Laboratory Test Method Verification44 citations
- Data secured in course of each test39 citations
Citation text
- “Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.”320 citations
- “Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.”132 citations
- “Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.”111 citations
- “The suitability of all testing methods is not verified under actual conditions of use.”77 citations
Show 2 more
- “Laboratory records do not include complete records of the periodic calibration of laboratory instruments.”45 citations
- “Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.”32 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 211.194, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Steril-Gene Life Sciences Private Ltd2026-08-12 · FEI 3014319211Complete test data included in records
Show 4 more
- The Procter & Gamble Manufacturing Company2026-06-09 · FEI 1017175Description and Identification of Samples
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.194 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 32 observations tie this way. The highlighted sentence is the matched wording.
Fresenius Kabi USA, LLC2026-05-14 · Observation 3
Verification of the suitability of the testing methods is deficient in that they are not performed under actual conditions of use. Specifically, your firm does not perform comparative testing for all in-house analytical method transfer studies that compare analytical results between the transferring lab and your receiving lab to determine a successful method transfer. For example, you did not compare the results of the transferring lab with the …
This observation opens with FDA's standard wording for 21 CFR 211.194(a)(2).
Zhejiang Huahai Pharmaceutical Co., Ltd.2026-04-24 · Observation 4
Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. A. There is a lack of laboratory data integrity. Bacterial colony growth in media growth promotion test (GPT) is inaccurately recorded to show acceptance result. Specifically, on 04/20/2026, I conducted a walkthrough inspection of the QC Microbiology Laboratory located in …
This observation opens with FDA's standard wording for 21 CFR 211.194(a).
USV Private Limited2026-04-17 · Observation 9
Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. Specifically, Your analysts have been given permission within the Empower software to view numerical results in the review window, allowing them to see area counts of peaks while changing the processing methods, without requiring the chromatograms to be saved. Using this …
This observation opens with FDA's standard wording for 21 CFR 211.194(a).
Show 2 more
Bentley Laboratories LLC2026-03-27 · Observation 4
The suitability of all testing methods is not verified under actual conditions of use. Specifically, Failure to ensure that the approved contract laboratory has performed method suitability of compendial methods USP <61> MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: MICROBRIAL ENUMERATION TESTS and USP <62> MICROBIOLOGICAL EXAMINATION OF NONSTERILE PRODUCTS: TESTS FOR SPECIFIED MICROORGANISMS, used for the testing of Total Aerobic …
This observation opens with FDA's standard wording for 21 CFR 211.194(a)(2).
Dendreon Pharmaceuticals LLC2026-03-25 · Observation 2
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy. Your firm's test method, (b) (4) entitled (b) (4) effective June 29, 2022, for Sipuleucel-T release lacks adequate independent verification of microbial contamination results. The procedure requires (b) (4) (b) (4) entitled "(b) (4)" effective March 10, 2026, no microscopic examination of (b) (4) by QC …
This observation opens with FDA's standard wording for 21 CFR 211.194(a)(8).
Warning letters stating a violation of 21 CFR 211.194
32 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your firm failed to ensure that laboratory records included complete data derived from all tests necessary to ensure compliance with established specifications and standards (21 CFR 211.194(a)).”
Each letter below states the violation in these words.
- Natural Essentials, Inc.Issued 2026-11-10
- Pritam International Private LimitedIssued 2026-10-27
- Eurofins SF Analytical Laboratories, Inc.Issued 2026-10-06
- Reliance Life Sciences Private LimitedIssued 2026-08-18
- Auriga Research Pvt. Ltd.Issued 2026-08-12
“Your firm failed to ensure that laboratory records included complete data derived from all tests necessary to ensure compliance with established specifications and standards. Your firm also failed to clean, maintain, and, as appropriate for the nature of the drug, sanitize and/or sterilize equipment and utensils at appropriate intervals to prevent malfunctions or contamination that would alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements (21 CFR 211.194(a) and 21 CFR 211.67(a)).”
- Rohto Pharmaceutical Co., Ltd.Issued 2026-10-14
Often cited at the same inspection
Of the 984 inspections where FDA cited 21 CFR 211.194, the share where it also cited each of these sections.
- 21 CFR 211.160General requirements500 (51%)
- 21 CFR 211.22Responsibilities of quality control unit404 (41%)
- 21 CFR 211.192Production record review376 (38%)
- 21 CFR 211.67Equipment cleaning and maintenance297 (30%)
- 21 CFR 211.100Written procedures; deviations294 (30%)
- 21 CFR 211.165Testing and release for distribution279 (28%)
Ask FDAgent about 21 CFR 211.194
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
Topics that count this section:Data integrity
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.194; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.