Zhejiang Huahai Pharmaceutical Co., Ltd.
Xunqiao Town, Linhai, China
FEI 3003999190DUNS 530732460
Company: Zhejiang Huahai Pharmaceutical Co., Ltd. · Linked by exact D-U-N-S match (530732460) in FDA registration data
FDA has 8 inspections on file for Zhejiang Huahai Pharmaceutical Co., Ltd. in Linhai, China (FEI 3003999190), from 2010 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below. Two of the seven FOIA requests for this site have asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER · Office of Manufacturing Quality). 3 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and API manufacturing, through Dec 31, 2027. Its registrant, Zhejiang Huahai Pharmaceutical Co., Ltd. (D-U-N-S 530732460), has registered 1 other site.
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 8, 2010–2026
- 3 OAI · 1 VAI · 4 NAI
- Inspections with 483 observations shown
- 3 of 8
- 1 posted 483 not matched to an inspection
- Requested under FOIA
- 7 requests, latest Jul 13, 2026
- Warning letters
- · CDER · Office of Manufacturing Quality ↗
- Import refusals
- 3 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Insufficient investigation and impurity risk analysis
Written records are not made of investigations into unexplained discrepancies the failure of a batch or any of its components to meet specifications. Specifically, no risk analysis exists to determine the root cause of the potential genotoxic and suspected human carcinogenic QQ have been found in your tablets. For example: A. Your firm sources its API Lo from [illegible] manufacturers which are solely determined by the customer. This API is received at the firm with a Certificate of Analysis (COA) from the API manufacturer. In reviewing a total of [illegible] COA for [illegible] we observed that testing for [illegible] are not done by the API manufacturer nor is any [illegible] analysis conducted by your firm. Since 2024 the firm has accepted [illegible] batches of [illegible] to manufacture [illegible] batches of bulk tablets of which [illegible] bulk batches ([illegible] tablets) were shipped to the United States. Additionally, while reviewing the firm’s documents, it was revealed that the firm [illegible] impurity testing of [illegible] APIs [illegible] Lo while [illegible] APIs
- Observation 2
Inadequate aseptic procedures and visual inspection
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, followed, or including adequate validation of the sterilization process. Specifically, A. During the inspection, I (EL) watched videos of airflow visualization studies (smoke studies) performed in Formulation Workshop [illegible] vial filling line in 01/2025. Workshop [illegible] manufactures [illegible] for the U.S. market. The lack of adequate smoke coverage, turbulent airflow, or poor aseptic practice were observed. Examples included but were not limited to: 1. You failed to provide an accurate airflow pattern presentation of your classified cleanroom under both static and dynamic conditions. Specifically, you did not establish study criteria for the smoke generator position or smoke velocity that allow for a comprehensive and meaningful study. Throughout the studies, the smoke generator was placed too far down from the HEPA airflow membrane. Additionally, the smoke velocity appeared high and did not match the HEPA velocity being studied. As a result, the smoke appeared being forced into the air stream leading the airflow instead of being carried by the actual HEPA airflow. 2. Video of static test #4-1 shows clockwise swirl of turbulent airflow on the left side of the smoke stream at the stopper station where a bag of sterile stoppers was staged and waiting to be dispensed. 3. Video of corrective intervention #3 shows multiple updrafts of airflow when the smoke hits the [illegible] surface on the right side of the smoke stream during rejection of inverted bottles on the line. You failed to demonstrate that laminar airflow moves down and out to sweep particles away from critical aseptic surfaces. 4. Video of corrective intervention #4 and #5 show that throughout the video, the smoke moves down and inward toward the direction of [illegible]. You failed to demonstrate that clean, laminar airflow moves down and out to sweep particles away from critical aseptic surfaces. 5. Video of corrective intervention #18 shows intervention being conducted in the [illegible] station. When the [illegible] [illegible] all the smoke left the Grade A critical zone and was blown out to the Grade B room leaving the filling station without HEPA coverage. You failed to demonstrate that the Grade A critical zone continues to receive HEPA first air coverage during intervention. 6. Video of corrective intervention #13-2 shows the stopper monitoring probe being taken out from the Grade A critical zone and moved to the Grade B room for adjustment during intervention. The probe was later returned to the Grade A area without first being sanitized. 7. During multiple interventions, the sterile bottle was moved from the Grade A to the Grade B area to sanitize the surfaces of the [illegible] RABS before [illegible]. The sterile bottle was returned to the Grade A zone without first being sanitized. B. On 04/18/2026, I (EL) observed the aseptic filling of [illegible] Injection, Batch No.: [illegible] (U.S. batch) in Formulation Workshop. The following deficient aseptic practice was observed. 1. During the dispensing of sterile stoppers, I observed an operator positioning a stopper bag directly over the [illegible], blocking HEPA first air to the [illegible] and sterile stoppers. The same deficient practice was also observed in MF and smoke study videos. 2. I observed an operator crossing the conveyor to get to the other side of the fill line. After [illegible] and moving the conveyor to the Grade B area, the operator failed to sanitize the exposed Grade A side of the [illegible] and the conveyor before [illegible]. I also observed the same operator moved a bottle of sterile [illegible] from Grade A to Grade B to clean the exposed Grade A surfaces of [illegible]. She later returned the bottle to Grade A area without first sanitizing it. C. There is a failure to perform adequate integrity testing that can pose critical risk to asep
Shortened here; the PDF has the full text.
Show observations 3 to 5
- Observation 3
Inadequate cleaning and disinfection practices
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. Specifically, there is a failure to adequately clean RABS/Grade A equipment surfaces. For example: A. SOP-F-SP-105.12, section [illegible], allows for a single clean cloth [illegible] to wipe up to [illegible] of the Grade A equipment surfaces. Therefore, the clean side of each cloth can wipe multiple surface areas until it is obviously dirty. You failed to follow the single-stroke per clean-side technique to prevent carryover of contamination from one area to a different area of the Grade A surface. B. During the inspection, I (EL) observed Grade A cleaning after batch production. I noted defined cleaning techniques were not followed. Specifically, 1. On 04/14/2026, I observed Formulation Workshop [illegible] Grade A cleaning after the production of [illegible] Injection, Batch No. [illegible] (non-U.S.). I observed an operator failed to perform overlapping strokes while cleaning the Grade A side of the RABS. SOP-F-SP-105.12, section [illegible] states wiping strokes shall overlap by [illegible]%. Additionally, while cleaning the operator did not clean [illegible] or perform visual inspection for damages as required per SOP-F-SP-130.07, section [illegible]. 2. On 04/15/2026, I observed Formulation Workshop [illegible] Grade A cleaning after the production of [illegible] Injection, Batch No. [illegible] (non-U.S.). I observed one operator wiping the surface (approximately [illegible]) in circular motion contradicting requirement per SOP-F-SP-126.02, section [illegible], where it states to clean the equipment surface [illegible]. Additionally, I observed a second operator cleaning [illegible]; however, he did not ensure thorough coverage as required per SOP-F-SP-130.07, section [illegible]. C. You lacked adequate justification for washing and sterilizing [illegible] used to sanitize pre and post batch production. [illegible] is used; however, at the end of each batch production not all used [illegible] are monitored; only [illegible] out of a total [illegible] in Workshop [illegible] and [illegible] out of [illegible] in Workshop [illegible] are sampled and tested for microbial contamination. Further, [illegible] is monitored, and [illegible] are sampled. You do not sample and test [illegible] to assure maximum coverage of monitoring.
- Observation 4
Laboratory data integrity and enumeration issues
Laboratory records do not include complete data derived from all tests, examinations, and assay necessary to assure compliance with established specifications and standards. A. There is a lack of laboratory data integrity. Bacterial colony growth in media growth promotion test (GPT) is inaccurately recorded to show acceptance result. Specifically, on 04/20/2026, I conducted a walkthrough inspection of the QC Microbiology Laboratory located in Building [illegible]. I reviewed GPT result for Lot No. [illegible] (EXP. [illegible]) after incubation (acceptance: colony growth <= [illegible]). [Illegible] is an indicator media used to detect the presence of objectionable microorganisms in raw materials, excipients, and FP for the U.S. market. I inspected Lot No. [illegible] for evidence of microbial growth. I did not see any cfu on tested [illegible] plates. My finding of no growth was confirmed by QC Microbiology Supervisor and Deputy Manager of QC Microbiology. However, the laboratory worksheet recorded 'B' indicating cfu growth was observed and 'Y' indicating the colony morphology is consistent. B. The Microbial Limit Test (MLT) is used to release all U.S. [illegible]. Your firm’s MLT results are not always reliable. Drug product particles and actual microbial growth (if present) cannot be adequately differentiated. Specifically, on 04/13/2026, I conducted a walkthrough inspection of the QC Microbiology Laboratory. I inspected the MLT Total Yeast and Mold Count (TYMC) form batches of [illegible] Tablets (non-U.S. product). All results were < [illegible] cfu/g indicating no microbial or cfu recovery. However, I noted widespread [illegible] dots encased inside the [illegible] media that cannot be ruled out as real microbial cfu recovery during testing. SOP-F-QC-366.04, 'Formulation Microbiological Laboratory Guidance for Enumeration of Colony Forming Units' lacks procedure for identifying and enumerating cfu when growth is encased inside the media. You also lack documented training to ensure your laboratory personnel can adequately recognize and enumerate microbial growth in the above scenario.
- Observation 5
Insufficient laboratory test methods and practices
Laboratory Controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, A. Your firm does not have a test method to conduct testing for [illegible] impurities. Therefore the firm is unable to test for [illegible] impurities. Upon further review of the firm’s other products test methods, it was observed that the firm does not have test methods for detecting impurities after cleaning equipment for product lines of [illegible] products. B. On 04/17/2026, while observing preparation for microbiological enumeration samples via [illegible], a microbiologist was observed using a [illegible] inside the ISO 5, Grade A laminar airflow workbench to sanitize the [illegible] manifold. Use of [illegible] can result in turbulence in laminar airflow of the Grade A workbench, damage to the HEPA filter, and has the potential to contaminate the clean area with [illegible]. No assessment has been carried out to evaluate the impact of the [illegible] transfer and potential degradation on microbiological analyses, to date. Personnel from your microbiology department did not demonstrate a robust understanding of the [illegible] process, as they stated that using [illegible] to sterilize the [illegible] holder was necessary to prevent sample contamination. Even when it was explained that [illegible] would retain microbiological contaminants on the [illegible] surface, the manifold 'sanitization' is utilized for [illegible] microbial analysis, and other product specific analyses.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Ineffective equipment cleaning
OBSERVATION #1 Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product 1. Cleaning of non-dedicated used to manufacture US market products was not effective. There are on-dedicated.._______l---,-,-""""'market product,;. The following was observed on cleaned equipment: ----.(bT(4 Prior to batcl__....,...,...._the equipment had undergone "Type C" changeover cleaning on January 15, 2025, that should have remove a product from the previous batch. On the morning of January 16, 2025, a production operator had visually inspected the equipment for cleanliness and approved the cleaning without identifying any 4 (b)( esidues. When the equipment was inspected later in the morning, after initial (bff4J or batch ~ had already .._____ ----- started, visible residues were observed in the following locations: (bT(i i..______ (b residues were observed in the l ive of the uct. Swab _____________.. sampling detected the presence o in this area...--- ~ 00~~ was last manufactured December 21 2024. Since that time, I,atches of ablets, •----. (liJ1 (b)l (bH ______. Tablets, ablets, and____ nd________Tablets had been manufactured on this --- --~------------------------1 equipment. This site was previously cited on an FDA 483 for failing to appropriately clean the CbTOO uctsofhe (b)(4 ---- ..___... ii. ndl esidues were observed on equipment surfaces on the underside of the -r---r- tthe bo the product container. No sampling of this area was conducted before the equipment was cleaned. ----.CbTC4l . 111.--,,--~-was observed on surfaces m the (6)1, ti o samp1·mg of th'is area was con ucted d be1orec the equipment was cleaned. ------- iv. CbT<\ were observed on the surface of the <6H4Yone. Swab sampling of this area detected (6,(4 ---- <6H4 . Cb)l .------.CbT(4 v•.....,.__~--! were observed m~t.e..1b.attra~~Wproduct from.______ o the..______ Swab sampling of this area detecte --------- 00 - r:esi.d~ff~ observed on the rim of the product container. Swab sampling identified___~_ nd vii.j l)-C4)~.s~w~e observed on the asket between the product container and Cb)l4l zone. Swab sampling .d .fi Cb><~, d <6fCl ---- 1 ent1 1 n --------- CbT viii.,.__-:--~--- was observed on external surfaces of the equipment. No sampling of this area was conducted before the equipment was cleaned. 0 ix. During additional inspectiol} of the equipment on January 20, 2025, th CbT( ducl and valve were observed to have t build-up on them. ...____ 4 11 4 b. On January 16, 2025, iff was observed on the [CbH•~alve on thC::Cb 4 p f the cleaned_:::~::r-.-:-(l/_.H_, GJC349-05. The investigation conducted by quality personnel was not going to include sampling of this visible lbH4 r the area behind the ~ alve on the l.b><Jduct. These areas were only swabbed after discussions 1 ~d...u_n,.._n_g-'!the inspection. When swab sampling of th l.bH residues was conducted and tested against the previous product, no peak was identified. _____. 4 On January 20, 2025, a buildup 0 C---Cti>< was observed on the (.bJl uct and valve for this piece of equipment. ----- c. On January 20, 2025, (.b)ll residues were observed on the ___ valve on the (.b)(-4 JC348-05. The investigation conducted by quality personnel was not going to incl._u_d_e_sa_m- pling of this area. ~iJ Swere only swabbed after discussions during the inspection. When sampling was performed, the AP is and L-.-_______ were detected. There was also stagnant liquid in th uct. ---- (.b)ll ; vas observed on the A buildup of uct and valve. ~IJ, January 20, 2025,.___~_rll_~ as observed on the surfaces of the uct and valve of the ~'GJC350-05. ---- .___... The_______ o,:rci.. uct and valve was not sampled as part of the quality investigation before it was cleaned. iH uct and valve on --- ------ (.b)ll During investigation sampling by quality personnel as detected in th ffl uct and valve. --- 2. Cleaning of non-dedicated 1.bTI4l equipmen
Shortened here; the PDF has the full text.
- Observation 2
Inadequate aseptic smoke validation
OBSERVATION #2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. 1. Smoke studies regarding Workshop used for aseptically filling ..____ (b__.njection, USP Cb>< gjl]}n Land ( ' ~~ L vials for the US Market: a. Air turbulence was observed for the following interventions: {6,(l i. Installation o for Stoppers ----- ii. Installation of Stopper Bowl into Line b. The following dynamic interventions were not evaluated in the smoke studies: 4 i. The (6}"( f stopper bags from Grade B onto the Grade A filling line platform, which occurs routinely during filling operations and up to Cbn4 ags at a time. 4 (b)( mo e studies did not evaluate this entire intervention and how the airflow during stopper 4 Cb><> might be impacted by the remaining bags stored on the platform. •------ 4 c. Smoke studies for dynamic ---. CbTOO' intervention o <6n is assemble and Installation was performed with the smoke generator pointing down, in the same direction as the airflow. It was not performed with the smoke generated pointing perpendicular to the airflow. 4 2. Smoke studies regarding Workshop [CbTysed for aseptically filling iJ( njection, USP ~gvial for the US market: ...,______ 4 4 a. The dynamic iJ( loading of the (bf{-4 l ials into the iJC was not evaluated as part of smoke studies. ---- -------- ,_____ 1141 b. Smoke studies for dynami9 (b interventions were performed with the smoke generator pointing down, in the same direction as the airflow. It was not performed with the smoke generated pointing perpendicular to the airflow. These include: i. Calibration of Scale prior to filling ii. Calibration of Scale after being filled iii. Adjustment o~ (b)C1 . . (b) (4 iv. Adjustment of .~ 4 (bTC, v 6 (bHl Removing, • v·,aIs at . . (b)(4) vii adjustment leading to l j 3. Smoke studies for Workshop were performed using [ ] generated from here has been no evaluation of whether this produces neutrally buoyant smoke.
Show observations 3 to 7
- Observation 3
Deficient visual inspection controls
OBSERVATION #3 There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. 1. The visual inspection qualification process for 100% manual visual inspection is deficient in the following ways: a. The visual inspection kits for liquid vials do not contain glass, metal, elastomer material, and fiber of known size. b. The visual inspection kits for liquid vials do not contain defect for precipitate (critical defect), group of particles (critical defect), smoke like particle deposit (critical defect), protein floccule (critical defect), appearance defect with impact on container closure system (critical), and significant appearance (bT(4J t major defect), which are defect categories listed in the visual inspection record of each batch. There is no assurance operators can adequately identify these type of defects, where applicable, during manual visual inspection process. 4 c. The visual inspection kits for l WCl ials do not contain defect vials for r (bTf} critical defect), (bTC4l 4 (bY{k major detect), and[ ~ major defect), which are defect categories listed in the visual inspection record of each batch. d. There is no complete defect library containing all defects for the liquid and [ CbH1',ials. e. Visual inspectors are required to be able to identify the defect vials during qualification and record the vial number in the corresponding defect row (such as critical, major, minor). The qualification records do not indicate what specific defect (such as glass, metal, etc.) was observed for each of these vials. f. There is no answer key for the current set of liquid test kits used to qualify operators for 100% visual inspection. After the most recent visual inspection qualification, the vial numbers were changed, but there is no record identifying which vial contains what defect after the change. 4 2. The l'------------- CbT(~ used during visual inspection of sterile liquid drug products 4 distributed to the US market in workshop1 CbH is not qualified. The original qualification performed in 2018 required a two-stage qualification. The second stage of the qualification has never been performed, and to date, there is no active protocol or schedule to complete Stage 2. Additionally, prior to use of this equipment for commercial batches, a pre- and post- rejection test, using standard vials, is required to be performed. These standard vials do not contain glass, metal, elastomer material, and fiber of known size. 3. Acceptable ranges have not been established during the tablet compression machines. Examples include, but are not limited to Cb)l4}rablets and CbH (Iablets for the US market: a. Studies have not been completed to establish the reject rates used during compression of tablets. There are no limits set in batch records and there is no process for setting the reject limits described in procedures used by the compression operators. Additionally, the operators have the ability to change the values for reject limits for each batch and to make changes during the batch. There has been no review of the electronic data to see what values were used during US market batches and to evaluate whether these values would have appropriately rejected non conforming tablets. b. Acceptable ranges for compression machine parameters that the operators can change have not been established. For example: feeder speed, fill depth, or target main compression force.
- Observation 4
Inadequate batch investigations
OBSERVATION #4 There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. 1. Deviation DF-23012 was opened when foreign matter was observed d.m_____(bTI of batch (bH f (bf~ able g (US Market). The batch was rejected. The investigation failed to perform any identification of the foreign matter or take any pictures. During the investigation, foreign matter similar in appearance was 4 4 observed in the (bRl uct of the H Z5029. The area was cleaned without any analytical evaluation of the observed residues and no pictures were taken. The investigation did not thoroughly assess whether contamination in this area could have impacted other batches made on this equipment. Additional batches made as part of the same campaign were not thoroughly inspected for the presence of foreign particles. (1' The investigation was not expanded to inspect the ucts and document findings in other (b)1 ----- used for the US market products. The cleaning procedures were not reevaluated to consider cleaning of this area during changeover between products. The area is cleaned during maintenance/ (b)Cj but there is no requirement for the maintenance personnel to document if they observe residues during maintenance activities. 2. Complaint investigation CF-23274 was opened when L.L. customer obtained an OOS for dissolution on 4 4 :I -l•JC1 and l.,_______00l___.rJ able~..___(b_ _H} ng batch. 1.,_____l.l>TI__,.i (EU market). The OOS was continued during testing of retain samples. The investigation identified higher main compression force during tableting, which had no established limits, as well as increased disintegration times during storage. The cause of the higher compression force was identified in the investigation as batch to batch variation, without further investigation of causes for the variation. The investigation was not extended to US market tablet products, which similarly had no established ranges for main compression force, to determine whether portions of batches were subject to variation leading to higher compression forces that could have produced non-conforming tablets. 4 3. Investigation OOT-FQC22020 was opened during stability testing of process validation batches of (b1(~ 4 4 Tablets for the US market at the f (b)( timepoint. The product is labeled with ~ __ (bY{l expiration date and has a specification for unknown impurities of not more than ~. Batch [ (bH~ i had a result of ~ and 1 4 batch (b>C4 had a result of (bH% for unknown impurities. The production investigation identified inter- batch variability as the result of higher impurities in these batches, but failed to understand what was causing this variation or what caused the impurity to form. The investigation did not thoroughly evaluate whether al (by(, expiration date was appropriate for ongoing commercial manufacturing given this data and the lack of understanding of the cause of variability that generated this impurity. 4 A different unknown peak has been detected in ~oe k (bTC4l- tablets stability batches. For example, batches (b)(4l (b)(4J .ci (b)(4 (b)(-0~ . . ___fan ____1 each had a result OJI oa____. compared to a specification of not more than (b)(fo. The peak was attributed to an excipient, but the specific excipient was not identified. No investigation evaluated why this peak is not detected in all stability batches if it is coming from an excipient, which should be present in all batches. 4. Investigation OOS-FQC23008 was opened for a content uniformity OOS result for batch WCl f ,___Cb_~_,)'ablets (US market). The batch was rejected. The investigation concluded the operators did not properly reject tablets at the end of the batch, resulting in lower assay results for tablets at the end of the batch, which caused the failure. No confirmatory testing of tablets from the end of the batch was conducted to support this concl
Shortened here; the PDF has the full text.
- Observation 5
Non-sterile tape in aseptic area
OBSERVATION #5 Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. On 16-Jan-2025, a 2 x 126 cm piece of non-sterile tape was observed between I (bTC4J t5haring 41 (b)( These sit below the HEPA filters and above where empty vials enter the line from the (b)(4} 4 I (b)(~ before being aseptically filled within Workshop~ the tape was placed between these (b)(~ seal an approximate 3 mm gap, which was observed sometime after the HEPA filters had been replaced around April 2024. This aseptic filling line is used to fill (bT(4l injection(s) for the US Market. 1. There is no record documenting when the gap was observed, who it was observed by, and if the gap was reported to the appropriate department including the Quality Unit. No investigation and subsequent CAPA plan into the cause of the gap has been made. 2. There is no record documenting the approval and use of the non-sterile tape to seal the gap within the Grade A filling line, and there is no work order or documentation detailing the installation, and subsequent replacement (if performed) of the tape. 3. An assessment was not performed to evaluate how the gap between the HEPA filter/ (b114? in the aseptic filling line and the use of the non-sterile tape within the area might impact airflow, cleaning, environmental monitoring, and product quality.
- Observation 6
Missing forced degradation studies
OBSERVATION #6 Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Analytical method validation studies have not included forced degradation studies for methods used for stability testing. For example, the US market products: J.____(b)l~blet, ~[ ~(b)l4' 0 nd l(b)l,4l Tablets, (b)l41 1I (b,(4)= (b)(4 :r (b)(4) rr 1--------•and1 ffablets, 1 Tablets, and1.___ __,1,ablets.
- Observation 7
QC lacks audit-trail authority
OBSERVATION #7 The quality control unit lacks authority to review production records to assure that no errors have occurred. 1. Procedures for audit trail reviews for production equipment have not been established: a. Production operators can make changes to compression settings. Quality personnel do not review audit trails that document parameters and changes. b. Production personnel can make changes to recipes for production and (6)l.J n the Workshop! (6)l-4~ L---------' Quality personnel do not review audit trails that document this information. (6)l4L 2. tuJC 100-01 and GJC 101-01 do not have an audit trail, do not save data, and requires personnel to manually input operating parameters for production an (bT( There is no quality unit verification of the manually entered information.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Sterile procedures not followed
OBSERVATION #1 Written procedures designed to prevent contamination of drug products purporting to be sterile are not followed. 1. During set-up and interventions using the RABS®® operators were observed to use thé®® directly above sterile surfaces and components. For example, ®® the stopper bowl and stoppers, and open vials at the®@ 2. Interventions during filling operations have not been defined in procedures and were not documented in the submission batch records. . . (0) (4) 3. There is no preventive change frequency for the clean room RABS 4. No defect set of vials is maintained for training and qualification of the visual inspection process
- Observation 2
Inadequate environmental monitoring controls
OBSERVATION #2 Failure to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. 1. Assessments to establish environmental monitoring sampling points were not comprehensive. For example, they did not evaluate expanded sampling points or thoroughly evaluate common activities occurring in the clean room. Further, the environmental monitoring procedures did not define sampling locations with descriptions or diagrams to ensure reproducible sampling. 2. Environmental monitoring media for air, surface, and personnel monitoring does not contain any neutralizers for the disinfectants used in the clean room. 3. During open door interventions, environmental monitoring is not performed. For example, non-viable particle counts, active air monitoring, or settle plates is discontinued during open door interventions. 4. Monitoring of the unfiltered bulk compounded batch does not include evaluation for endotoxin and the samples are collected at least®® prior to the start of . _— . . o@ . 5. oat Dre is a lack of scientific rationale for {he establishment of the parameters for the RABS integrity test of] pressure hold time between + Paand greater than Pa drop in pressure. 6. Limits on reject types are not established in the visual inspection procedures.
Show observations 3 to 4
- Observation 3
Deficient cleaning and disinfection system
OBSERVATION #3 Processing areas are deficient regarding the system for cleaning and disinfecting the equipment. yal he ducts of the®® are not periodically inspected and cleaned. On 18 November 2016, the oe duct for GJC008 was observed to have unidentified white dust on the inner surfaces of the duct. O10) . . © : 2 of the filling room is done to control spores with a” ©@ solution. The validation of the process did not include placement of biological indicators in hard | reach areas, such as in RABS areas that may be blocked by equipment, high areas or low areas. - a N ©) 43, Disinfectant efficacy studies did not evaluate the effectiveness on” used for the RABS Sa used as. parts for the filling line. During execution of the studies the challenged surfaces were physically wiped preventing evaluation of the effectiveness of the disinfectant that is sprayed. . CIO) . . . 4. Transfer of the filling machine parts from their storage in unclassified areas to the Grade A areas was not evaluated in the validation “Efficiency Qualification of Material Transferring by Non-Sterilization Method into Grade B”.
- Observation 4
Data not recorded contemporaneously
OBSERVATION #4 Data is not recorded contemporaneously. . ®@ © 1. The “checked by” entries for batch of Tablets were not documented at the time of batch production. 2. The QC analyst responsible for environmental monitoring does not document sampling at the time it occurs. It ‘was reported the analyst remembers the times and documents all at once after finishing.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on Jul 13, 2026. Each one asked for a Form 483.
Inspection ending Apr 24, 2026OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 13, 2026FDA-FOIA-2026-6644Form 483· 1 of 2 sitesRecords released
- May 18, 2026FDA-FOIA-2026-5043Form 483Records released
Inspection ending Jan 24, 2025OAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Jul 19, 2025FDA-FOIA-2025-8858Form 483· 1 of 3 sitesClosed
- Jun 16, 2025FDA-FOIA-2025-7678Form 483· 1 of 9 sitesWithdrawn
Inspection date not given
3 requests. None of FDA’s log entries for these requests say records were released.
- Mar 6, 2026FDA-FOIA-2026-2289Form 483· 1 of 4 sitesClosed, no reply from requester
- Apr 23, 2025FDA-FOIA-2025-3680Form 483Closed
- Jan 24, 2025FDA-FOIA-2025-720Form 483 + EIRClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Office of Manufacturing Quality · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003999190, one row per refused product line.
3 refusals from 2023-02-27 to 2025-10-23 · charged FRNMFGREG on 1, DIRSEXMPT on 1 · FDA sample analysis on 1
FDA firm profile- 2025-10-23
GABAPENTIN (ANTI-DEPRESSANT)61NIY69
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Southeast ImportsAEK-7622323-7/10004/1
- 2024-04-22
FOSINOPRIL SODIUM (ANTI-HYPERTENSIVE - PART II)62OCR34
DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING
Division of Northeast ImportsKL1-0279689-5/11/1
- 2023-02-27
LEVETIRACETAM (ANTI-CONVULSANT)61MCB42
DR QUALITY 501(b), 801(a)(3); ADULTERATION
FDA sample analysis
Division of Southeast ImportsBUU-1528343-1/21/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Zhejiang Huahai Pharmaceutical Co., Ltd.D-U-N-S 530732460
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Zhejiang Huahai Pharmaceutical Co., Ltd. (D-U-N-S 530732460) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Zhejiang Huahai Pharmaceutical Co., Ltd.Linhai, China · FEI 30038857456 inspections6latestNov 20, 2024VAI1 warning letter, Nov 29, 2018
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003999190 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003999190. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.