Zhejiang Huahai Pharmaceutical Co. Ltd. Form 483, November 2016
FDA issued this Form 483 to Zhejiang Huahai Pharmaceutical Co. Ltd. in Linhai, China (FEI 3003999190) at the end of a drug inspection that ended November 18, 2016. It lists 4 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Aug 9, 2018. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Nov 18, 2016
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Aug 9, 2018
- 629 days after the inspection
The 4 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Sterile procedures not followed
OBSERVATION #1 Written procedures designed to prevent contamination of drug products purporting to be sterile are not followed. 1. During set-up and interventions using the RABS®® operators were observed to use thé®® directly above sterile surfaces and components. For example, ®® the stopper bowl and stoppers, and open vials at the®@ 2. Interventions during filling operations have not been defined in procedures and were not documented in the submission batch records. . . (0) (4) 3. There is no preventive change frequency for the clean room RABS 4. No defect set of vials is maintained for training and qualification of the visual inspection process
- 2
Inadequate environmental monitoring controls
OBSERVATION #2 Failure to establish laboratory controls that include scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality, and purity. 1. Assessments to establish environmental monitoring sampling points were not comprehensive. For example, they did not evaluate expanded sampling points or thoroughly evaluate common activities occurring in the clean room. Further, the environmental monitoring procedures did not define sampling locations with descriptions or diagrams to ensure reproducible sampling. 2. Environmental monitoring media for air, surface, and personnel monitoring does not contain any neutralizers for the disinfectants used in the clean room. 3. During open door interventions, environmental monitoring is not performed. For example, non-viable particle counts, active air monitoring, or settle plates is discontinued during open door interventions. 4. Monitoring of the unfiltered bulk compounded batch does not include evaluation for endotoxin and the samples are collected at least®® prior to the start of . _— . . o@ . 5. oat Dre is a lack of scientific rationale for {he establishment of the parameters for the RABS integrity test of] pressure hold time between + Paand greater than Pa drop in pressure. 6. Limits on reject types are not established in the visual inspection procedures.
- 3
Deficient cleaning and disinfection system
OBSERVATION #3 Processing areas are deficient regarding the system for cleaning and disinfecting the equipment. yal he ducts of the®® are not periodically inspected and cleaned. On 18 November 2016, the oe duct for GJC008 was observed to have unidentified white dust on the inner surfaces of the duct. O10) . . © : 2 of the filling room is done to control spores with a” ©@ solution. The validation of the process did not include placement of biological indicators in hard | reach areas, such as in RABS areas that may be blocked by equipment, high areas or low areas. - a N ©) 43, Disinfectant efficacy studies did not evaluate the effectiveness on” used for the RABS Sa used as. parts for the filling line. During execution of the studies the challenged surfaces were physically wiped preventing evaluation of the effectiveness of the disinfectant that is sprayed. . CIO) . . . 4. Transfer of the filling machine parts from their storage in unclassified areas to the Grade A areas was not evaluated in the validation “Efficiency Qualification of Material Transferring by Non-Sterilization Method into Grade B”.
- 4
Data not recorded contemporaneously
OBSERVATION #4 Data is not recorded contemporaneously. . ®@ © 1. The “checked by” entries for batch of Tablets were not documented at the time of batch production. 2. The QC analyst responsible for environmental monitoring does not document sampling at the time it occurs. It ‘was reported the analyst remembers the times and documents all at once after finishing.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3003999190, newest first.
- Form 483, April 2026Inspection ended Apr 24, 2026 · Posted Jul 13, 2026OAI
- Form 483, January 2025Inspection ended Jan 24, 2025 · Posted May 23, 2025OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.