Zhejiang Huahai Pharmaceutical
Coastal Industrial Zone, Duqiao, Linhai, China
FEI 3003885745DUNS 421262001
Company: Zhejiang Huahai Pharmaceutical Co., Ltd. · Linked by exact D-U-N-S match (530732460) in FDA registration data
FDA has 6 inspections on file for Zhejiang Huahai Pharmaceutical in Linhai, China (FEI 3003885745), from 2010 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below. One of the four FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Aug 3, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and API manufacturing, through Dec 31, 2027. Its registrant, Zhejiang Huahai Pharmaceutical Co., Ltd. (D-U-N-S 530732460), has registered 1 other site.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2010–2024
- 1 OAI · 2 VAI · 3 NAI
- Inspections with 483 observations shown
- 2 of 6
- Requested under FOIA
- 4 requests, latest Mar 6, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Missing raw lab test data
Laboratory records do not include complete test data derived from all tests. Specifically, A. There is no documentation of raw test data relating to equipment cleaning samples (solution preparation). For example, Your analytical test procedures for detection of [illegible] series of steps such as [illegible] solution, however your Quality Unit has not established any system in the form documenting cleaning test solution preparation. There is no documented cleaning test solution preparation pertaining to a laboratory. According to your Quality Assurance Manager, about [illegible] Spectroscopy and about (b)(1)% of cleaning samples are tested [illegible] documentation relating to cleaning samples test solution preparation. Thereby, there is no assurance of the reliability of cleaning samples test result and [illegible] failures. There is a potential for carryover and cross-contamination of degradants between APIs and intermediates that are [illegible] your site. This issue is applicable to all APIs and intermediates that are manufactured [illegible] the ones for the U.S. market. Your Quality Unit has deviated from the following procedures for documenting the test solution preparation: SOP No.: SOP QC-021-19, Titled: "Recording and Review Procedure for Laboratory's Record", Version: 19, Effective date: June 30, 2024, Section 3.1 relating to QC Analyst responsibilities to "Ensure that the test records are written in a timely, accurate manner". Additionally, your Laboratory Manager and QA also deviated from [illegible] of test results in the absence of raw test data regarding general requirement for record writing, standards, 5.3.9 - regarding documentation requirement for reference preparation, 5.3.11 - regarding documentation requirement for testing. SOP No.: SMP-035.05, Titled: Data Integrity Management System, Version: [illegible], Effective date: [illegible], section 3.1 relating to ALCOA++ General principles. B. There is no documented test procedure established to include details pertaining to diluent preparation, stepwise instructions into [illegible] and rinsing preparation for [illegible] commercialized into the U.S. market. Similar [illegible] and APIs that were manufactured using [illegible] U.S. market.
- Observation 2
Analytical procedure deviations
Deviations from analytical test procedures are not investigated. Specifically, A. Your Quality Control Unit deviated from [illegible] equipment cleaning samples for APIs and intermediates by not preparing and [illegible] and linearity for UV Spectroscopy and TOC prior to testing cleaning test [illegible] is applicable to testing of cleaning samples of [illegible] for the U.S. market. B. Your Quality Unit deviated from equipment cleaning samples (swab and rinse) test procedure by using "E value" (UV extinction coefficient) method to calculate test results instead of the linear equation that is required per your analytical cleaning samples test procedures. For example, Per your Test Procedures QS-C054, and QS-C006 for [illegible] equipment cleaning solution, linear equation calculation is required to calculate results by UV Spectroscopy. However, your QC Engineers referenced procedure SOP QC-048, titled: "API production cleaning solution testing practices" to calculate test results by "E value" calculation. Per your QC Deputy Director, results calculated by E value equation would not be the same. Moreover, your QC Engineers bypassed preparations to establish linearity plot of UV Spectroscopy system prior to testing cleaning [illegible]. In the absence of linearity value, your QC Engineers used E value only and [illegible] different concentration reference standard prepared to each API several years ago. Thereby, cleaning sample test results calculated for a [illegible] are unreliable due to not establishing UV Spectroscopy performance and linearity to ensure accuracy of UV Spectroscopy measurement. This deficiency is applicable to [illegible].
Show observations 3 to 8
- Observation 3
Inadequate OOS investigations
Laboratory investigations are not adequately conducted to determine the root cause. Specifically, Your Out-of-Specification (OOS) investigations for equipment cleaning [illegible] include scientific justification supported with documentation. Several investigations were closed. For example, A. OOS investigation numbers: OOS-CQC22149, OOS-CQC150, and OOS-CQC151, date initiated: December 13, 2022, description of OOS event: acceptance limit criteria for TOC test. The following results were obtained: • For OOS-CQC22151, Batch number: (b)(4) [illegible] mg/L, Sample type: Swab sample, Equipment [illegible]. Your Quality Unit determined the probable root cause [illegible] bottle. We observed the following deficiencies in these investigations: 1) There were <6 total cleaning samples (swab and rinse) collected; during the investigation, your firm failed to determine that raw test data pertaining to cleaning sample solution preparation, along with calculations used for calculating test results were not documented for all samples tested using TOC. In the lack of documented raw test data, there is no assurance over the reliability of reported test results for all samples. 2) There was no simulation experiment conducted to scientifically prove whether cleaning samples failed to meet acceptance [illegible]. As a result of the deficiencies mentioned above and categorizing the root cause to production operator's sample collection technique, your firm did not reclean equipment and continued to use them in the manufacturing. B. [illegible] investigation number: OOS-COC24011, [illegible] cleaning solution batch [illegible] [illegible].
- Observation 4
Deviation investigations not conducted
Deviation investigation relating to facility, equipment and production are not always investigated. Specifically, On November 12, 2024, we observed a total of about [illegible] files on the local drive of your IT Supervisor's laptop for the issues related to rusted, leaking and disrepair state of manufacturing equipment along with documentation of yellow colored uncontrolled paper among some records. Documentation Practices and Data Integrity concerns. Most issues were reported by your IT Supervisor. On November 12, 2024, your IT Supervisor stated that upon discovering significant GMP issues during his visit to production workshops on September 23, 26, 27 and October 1 he documented the issues on two (2) separate uncontrolled spreadsheets. Further, according to him the issues were reported to the respective production workshop management personnel. However, these observed issues were not reported to QA department and there was no deviation investigation conducted. Upon discussing the observation, your firm initiated a deviation investigation and closed this investigation on November 14, 2024 without determining the root cause for each issue reported by IT Supervisor. There was no documented interview [illegible] assessment performed. Additionally, there was no corrective action and preventative action (CAPA) taken by your firm to ensure employees are trained and adequate procedures as required are established. On November 19, 2024, we evaluated some of the issues from the pictures (taken [illegible]) and observed integrity of your manufacturing data is not always maintained. Your production operator potentially recorded [illegible] on colored uncontrolled paper and placed [illegible] relating to the process validation of [illegible]. Information on page 53 of 57 was found not written in September 23, 2024. However, the verification of BMR on November [illegible] in BMR was on September 24, 2024. This is reflective of inconsistent information. Furthermore, raw data handwritten in black color ink pen on a piece of [illegible] handwritten in black color ink pen on this BMR. Six (6) out of [illegible] were handwritten [illegible] whereas the numbers found handwritten [illegible] were [illegible].
- Observation 5
Insufficient Quality Unit oversight
Lack of Quality Unit oversight to ensure integrity of [illegible]. Specifically, A. On November 14, 2024, we observed [illegible] cleaning samples received in your QC between October 29 to November 14, 2024. Even after repetitively discussing observations regarding reliability in the absence of raw test data relating to documentation of cleaning test solution preparation along with not verifying the UV Spectroscopy and TOC equipment performance through reference standards (refer to Observations 1A and 2A), on November 18, 2024 your QC Director allowed your QC Engineers (Analysts) to continue testing and documenting diluent preparation, test solution preparation, and without establishing a series of different concentration reference standards to evaluate system suitability and performance for UV Spectroscopy and TOC. Further, the Production Unit of your firm continued to keep manufacturing APIs and intermediates utilizing most of equipment without confirming if they were cleaned or not. B. Your Quality Unit lacked oversight on destruction practices. On November 12 and 13, 2024, we observed white shredded pieces of documentation in the documentation room of your west direction QC building. Your firm used shredders for GMP and non-GMP documents. Your firm maintained shredding machines in production, technical, and process engineering departments among other non-GMP areas (administrative and finance department) of your facility. There is no oversight from your Quality Assurance department on controlling and management of GMP documents that are potentially shredded inside these departments.
- Observation 6
BMR lacks time/speed limits
The master batch production record lacks an established time limits and criteria to ensure the quality of intermediates and APIs are met for individual processing steps and/or total process. Specifically, Your firm failed to establish and document a specific speed range for the steps in the manufacturing process of [illegible]. Your firm has minimum time requirements for the process, but failed to document at what (li) speed [illegible] can be adjusted by your operator through [illegible] and [illegible] located in workshops. Operational speeds and capabilities were adjusted by the operators at [illegible] and were used by the operators at random; changes were not documented on the BMR. Since July 2021 a total of [illegible] lots were manufactured with no (b)(4) speed documented in the BMR. On November 13, 2024, while performing an inspectional walkthrough, for Batch Number [illegible] we asked the operator how much time the [illegible] was to be continued before finishing the step; at the same time, we asked the workshop director to inform how much time to continue, and he responded [illegible]. The process end time is subjective to the operator discretion and not based on a scientifically measurable limit established on your BMRs. Your BMRs document the start and the end time for the [illegible] step but do not record a measurable objective end time for the [illegible] process. Furthermore, [illegible] had operational speeds [illegible] in purification steps; this speed is not documented. Since July 2021 a total of [illegible] lots were manufactured with no minimum time recorded in the BMRs. All lots are within their retest period.
- Observation 7
Equipment maintenance deficiencies
Equipment used in the manufacture of intermediates and APIs should be maintained to prevent contamination that would alter the safety, identity, strength, quality and purity. Specifically, During the inspectional walkthrough, on November [illegible] we observed manufacturing equipment used in the manufacturing of APIs and intermediates [illegible] that are [illegible] that a preventive maintenance check was not performed. For example, [illegible] pieces of [illegible] at the [illegible] piping in your firm that are [illegible] and the condition of the [illegible] materials showed external flaking out with some missing [illegible]. Preventive maintenance records (PMs) show [illegible] on some equipment. In November 2023, a total of lots of [illegible] were manufactured using this equipment with respective release date. This deficiency was not addressed and these lots remain within their retest period. The condition of the manufacturing equipment is deficient.
- Observation 8
Deficient cleaning-sample procedures
The procedure for collecting cleaning samples from the manufacturing equipment is deficient. Specifically, While performing an inspectional walkthrough of Workshop [illegible], officials explained that for the Cleaning Validation of [illegible] 309 swab samples were collected by production operators going physically inside of [illegible] distance of the swabbing locations from the equipment. In Validation Protocol in Workshop [illegible] Document Number: CVC-20036(P) we observed that there is no protocol on how your operators physically enter this equipment without compromising equipment cleaning and its qualification. Your cleaning validation protocol does not describe gowning requirements for the operators or provide sufficient detailed instructions to determine the specific swabbing location on the equipment. Your firm cleaning validation protocol is deficient on controls during the sampling process. Your operators are entering inside the equipment from a room that [illegible] evaluated for cleanliness and this practice can potentially further contaminate the equipment sampled and then used in the manufacturing process. A number of lots were manufactured using both the [illegible] ID: [illegible] and are currently within their respective retest dates for the U.S. market.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate QC analytical controls and investigations
OBSERVATION 1 Appropriate controls are not implemented over Quality Control instruments to ensure the integrity of analytical testing. Furthermore, anomalies in analytical testing are not investigated. 1. During a review of API testing assay testing is repeated in order to obtain satisfactory/ within specification results: Standard Operating Procedure (SOP) QC-024-5 requires that replicate samples subject to analysis for assay to exhibit no more than 4% difference in result. This SOP was utilized to engage in repeat analysis of API in instances of out-of-specification and out-of-trend results without a corresponding investigation. Examples may be found below: (a) [ batch” exhibited a large differential between replicate sample results, such that one injection yielded an out-of-specification. The initial failing injections were not processed. Due to this large differential, this batch of” was retested without conducting an investigation and passing results were reported. (b) 2° bageh®” exhibited failing assay result for one of the replicate injections (?® % against a specification of(s) 4). Due to a large differential in test results between replicate injections for” this batch was retested without conducting an investigation and passing results were reported. (c) The following batches exhibited out-of-trend results, which were retested without an investigation due to a greater than(y)'% differential in replicate assay injections: i. batch ii. batch ii. batch iv. o@ batch®®@ Further, due to this repeat testing as a result of discrepancies in replicate assay values, I reviewed repeat analytical testing for BE which exhibited an increased rate of repeat testing. The replicate samples from repeat testing conducted between September 2016 and March 2017 for ®@ exhibited an average differential in assay results of approximately” /% (with the acceptable range of the specification spanning 3%). The replicate samples from repeat testing conducted between September 2016 and March 2017 for ®® ©) @ exhibited an average differential in assay results of approximately“ % (with the acceptable range of the specification spanning) 4). I asked your firm's Quality Control Director to explain how such routine, large differences in assay values of replicate samples was consistent with assurance that the analytical method is effective and released API indeed met specification. They did not provide a sustentative explanation. Note: this repeat testing encompassed subjecting the same API batch to repeat testing without investigating the initial test results and the requirement for re-testing. 2. Impurities occurring during analytical testing are not consistently documented/ quantitated. (a) Testing of content of batch by Liquid Chromatography-Mass Spectrometry yielded an unidentified peak at an approximate retention time of s) minute. Your firm explained this unknown peak as a “ghost peak” that appears from time to time in chromatograms for undetermined reasons. This peak was substantially larger than that of ® the subject of the testing. No investigation was conducted. (b) Testing of content of batches by Liquid Chromatography-Mass Spectrometry yielded an unidentified peak at an approximate retention time of minute until the end of the chromatogram. This peak was substantially larger than that of the subject of the testing. No investigation was conducted. (c) Impurity testing of batches” yielded a prominent, coalescing peak with that of the primary ® @ peak. Nevertheless, the impurity was quantitated along with the ®®) peak as desired API and no investigation was initiated.
- Observation 2
Poor maintenance; contaminated equipment
OBSERVATION 2 Facilities and equipment are not maintained to ensure quality attributes of drug product. a) On May 15, 2017, 0@ V-305 exhibited particulate matter and paint on the inner face of the gasket to the ®@ ®@ RL. Further, this gasket was fraying, and loose threads were visible. The gasket inside the ®@ had deteriorated such that the missing portions could not be accounted for. The mass balance of this gasket could not be accounted for. Further, this gasket was discolored brown. Finally, a portion of the interior of this ® was discolored white. This ®® was utilized in the manufacture of [illegible] intended for the US market. This equipment was in the clean status. b) On May 15, 2017, the ®® to @ 109-805 contained screws displaying a reddish-brown discoloration consistent with rust (interior of the ®@). This ®® was utilized in the manufacture of lot JX intended for the US market. This equipment was in the clean status and is used in the [illegible]. c) On May 15, 2017 ®0@ IX-501-2 exhibited particulate matter and blue paint on the inner face of the gasket to the ®®. Particulate matter and paint were falling from the ® upon opening the ®. Further, this gasket was fraying, and loose threads were visible. The gasket inside the ®@ had deteriorated such that the missing portions could not be accounted for. The mass balance of this gasket could not be accounted for. Further, this gasket was discolored brown. Finally, the interior of this ® was discolored brown. This ®® was utilized in the manufacture of ®® for ®@ intended for the US market. This equipment was in the clean status. d) On May 15, 2017 0@ IX-501-1 exhibited what appeared to be flaking of the surface to the ®®. The gasket inside the ®@ had deteriorated such that portions of the gasket were missing and threads of the gasket were fraying. The mass balance of this gasket could not be accounted for. This ®® was utilized in the manufacture of ®® lot ®@ intended for the US market. This equipment was in the clean status. e) On May 15, 2017, the ®@ W02-802-2 exhibited white particulate facing the interior of the ® that appeared to originate from the gasket to the ®®. Further, this ® appeared heavily scratched. This was utilized in the manufacture of ®® lot [illegible] intended for the US market. This equipment was in the clean status and is used in the ®®. f) On May 16, 2017, ®@ 1-319 exhibited what appeared to be white particulate matter in the interior of the ®. The gasket inside the ® had deteriorated such that portions of the gasket were missing and threads of the gasket were fraying. The mass balance of this gasket could not be accounted for. This was utilized in the manufacture of lot ®@ intended for the US market. This equipment was in the clean status. For the aforementioned Observation, the following complaints pertaining to your firm’s API were noted: i. CC-16006 addressing ® © particles ®® color, yellow rust in ® © batch ®® ii. CD-15004 reporting “black metallic particles” in batch ® @ iii. CD-15003 addressing “mixed fragment ®® ” in batch [illegible] iv. CD-15006 stating “black particles were found in ® © batch ®® v. CD-15001 reporting “That ®@ particles is ®@ ”. The affected product is ®@
Show observation 3
- Observation 3
Unjustified invalidation of OOS results
OBSERVATION 3 Invalidation of out-of-specification results lacks adequate scientific justification. a) Report 00S-CQC15067 relating to (®@ batch(® © was reported “Unknown impurity peak is appeared under unknown reason”. Your firm explained this unknown peak as a “ghost peak” that appears from time to time in chromatograms for undetermined reasons. Without an indication of the cause of the out-of-specification, an attribution of “Lab error” was made. b) Report 00S-CQC16103 reported out-of-specification of residual solvents in ®. The Phase I laboratory investigation failed to identify a laboratory error. This investigation attributed the failure to “Pollution” from the environment during sample preparation. c) Report 00S-CQCf}5103 due to a single impurity in batch {, against a specification of no more than ~~ %). This was assigned as a “Lab error” due to “possible” residue in the column. When inquiring about why this impurity specifically eluted in the analytical test of the testing sequence, your firm again referenced a “ghost peak”.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Mar 6, 2026.
Inspection ending Nov 20, 2024VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Feb 25, 2025FDA-FOIA-2025-1740Form 483· 1 of 2 sitesWithdrawn
Inspection ending Sep 8, 2010NAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Mar 7, 2024FDA-FOIA-2024-2412EIRClosed
Inspection date not given
2 requests. None of FDA’s log entries for these requests say records were released.
- Mar 6, 2026FDA-FOIA-2026-2289Form 483· 1 of 4 sitesClosed, no reply from requester
- Apr 12, 2022FDA-FOIA-2022-2675EIR· 1 of 3 sitesWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Zhejiang Huahai Pharmaceutical Co., Ltd.D-U-N-S 530732460
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Zhejiang Huahai Pharmaceutical Co., Ltd. (D-U-N-S 530732460) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Zhejiang Huahai Pharmaceutical Co., Ltd.Linhai, China · FEI 30039991908 inspections8latestApr 24, 2026OAI1 warning letter, Jun 6, 2025
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003885745 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003885745. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.