Skip to content

Dendreon Pharmaceuticals LLC

California, USA

FEI 3008821247DUNS 079879298

Company: Dendreon Pharmaceuticals LLC · Linked by exact D-U-N-S match (079879298) in FDA registration data

FDA has 6 inspections on file for Dendreon Pharmaceuticals LLC in California (FEI 3008821247), from 2012 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.192 and 21 CFR 211.113(b).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant, Dendreon Pharmaceuticals LLC (D-U-N-S 079879298), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
6, 2012–2026
0 OAI · 5 VAI · 0 NAI
Inspections with 483 observations shown
4 of 6
Form 483s posted by FDA
↗
Requested under FOIA
3 requests, latest Jul 7, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 9 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Incomplete investigations of discrepancies and failures

      Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. Although your firm's Quality Unit approved a written procedure, SOP-11058.33, entitled "Nonconformance Reporting," effective August 9, 2025, which defines the nonconformance management process, investigation, assessment of impact, determination of root cause, implementation of corrections, identification of corrective actions, documentation, and reporting of process nonconformities, your firm failed to thoroughly investigate the following: a) Non-conformance NC-2025-0053, initiated on May 23, 2025, investigated the visual inspection failure of final product bags with lot number (b) (4). The final product bags from this lot did not meet the required visual inspection criteria: (b) (4) units contained embedded particulates on the product (b) (4) surface, and (b) (4) units contained embedded particulates on the (b) (4) product (b) (4) surface. Despite these findings, the lot was approved for use by Supplier Quality Assurance (SQA). This lot was subsequently used in the manufacturing of (b) (4) final product batches of Sipuleucel-T and remains the current lot in use for finished product. b) For critical material, (b) (4), Lot # (b) (4) were rejected during the (b) (4) packaging operation post-sterilization due to defects such as cracked (b) (4) and (b) (4). However, Quality Unit did not investigate the defects. c) For critical material, (b) (4) Lot # (b) (4) were rejected during the (b) (4) packaging operation post-sterilization due to defects such as (b) (4) and (b) (4). However, Quality Unit did not investigate the defects. d) For critical material, (b) (4) Lot # (b) (4) were rejected during the (b) (4) packaging operation post-sterilization due to defects such as (b) (4) and (b) (4). e) Non-conformance NC-25007 dated April 7, 2025, investigated the failure of (b) (4) samples from (b) (4) and (b) (4) that failed the (b) (4) stability test for density. The (b) (4) sample results were out of specification (OOS) for the required density range for (b) (4). The investigation concluded that the (b) (4) needed to be (b) (4) testing. New samples from the batches were tested for density, the results passed, and the conclusion stated that there was no impact on the (b) (4) batches. The non-conformance failed to thoroughly investigate the stability failure in that there was no evaluation on the impact on the final drug product. (b) (4) lot (b) (4) was used to manufacture approximately (b) (4) units of your Sipuleucel-T final drug product, including lot number (b) (4) which was released on (b) (4). f) Laboratory Investigation LIR-2023-0144 dated Nov 17, 2023, examined a Day (b) (4) BacT alarm for an (b) (4) at (b) (4) for batch (b) (4) final product. Preliminary (b) (4) (b) (4). The investigation used a (b) (4) BacT (b) (4) that had been (b) (4) for (b) (4), violating work instruction WI-000496.1, entitled "Work Instruction for the Completion of Sterility Test Laboratory Investigations" effective January 31, 2023, which requires (b) (4) per SOP-11002. The firm concluded the BacT alarm and (b) (4) were (b) (4), without justification, changed results from "(b) (4)" to "(b) (4)" and issued a new Sterility CoA. Since February 2024, your firm has manufactured approximately (b) (4) of (b) (4) and approximately (b) (4) of (b) (4). Of those manufactured (b) (4) approximately (b) (4) have been shipped to your sister location in Georgia. The (b) (4) solutions are used to (b) (4) the target cells during your Sipuleucel-T manufacturing process. THIS IS A REPEAT OBSERVATION

    2. Observation 2

      No second-person review of laboratory records

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy. Your firm's test method, (b) (4) entitled (b) (4) effective June 29, 2022, for Sipuleucel-T release lacks adequate independent verification of microbial contamination results. The procedure requires (b) (4) (b) (4) entitled "(b) (4)" effective March 10, 2026, no microscopic examination of (b) (4) by QC reviewers. On March 19, 2026, this was confirmed when an analyst performed (b) (4) for batches (b) (4) and (b) (4), and a (b) (4) analyst stated reviewers verify only (b) (4). This test is used for product release before final sterility testing is completed.

    Show observations 3 to 9
    1. Observation 3

      Inadequate aseptic procedures and environmental monitoring

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. 1. Your written procedures (b) (4)-100448.13, entitled, "Cleaning of the ISO Classified and CNC Areas at the Seal Beach Facility," effective July 19, 2025, and (b) (4) 100168.12, entitled "Cleanroom Behavior at the...Manufacturing Facilities," effective May 23, 2024, are inadequate in that they lack detailed instructions to prevent contamination of sterile biological drug products and to perform aseptic manufacturing and cleaning of classified areas. The following deficiencies were observed during manufacturing activities for Sipuleucel-T: A. On March 18, 2026, we observed the following deficiencies during the culture bag filling operation of a Sipuleucel-T, Day (b) (4) processing for batch (b) (4) at workstation (b) (4): I. An operator (b) (6), (b) (7)(C) was observed not sanitizing (b) (6), (b) (7)(C) hands before entering and exiting the biological safety cabinet, ISO (b) (4) environment on multiple instances during the processing of Sipuleucel-T II. The (b) (4) and (b) (4) used in processing are not always sanitized (b) (4) moving from manufacturing module ISO (b) (4) environment to ISO (b) (4) Biological Safety Cabinet (BSC). B. On March 18, 2026, we observed the following deficiencies during the culture bag filling operation of a Sipuleucel-T, Day (b) (4) processing for batch (b) (4) at workstation (b) (4): I. The operator (b) (6), (b) (7)(C) was observed entering and exiting the ISO (b) (4) Biological Safety Cabinet (BSC) from the ISO (b) (4) environment without sanitizing hands with (b) (4) II. The operator (b) (6), (b) (7)(C) was observed entering and exiting the ISO (b) (4) BSC quickly, transferring materials into BSC without sanitizing hands with (b) (4) C. On March 19, 2026, we observed the following deficiency during the cell harvest operation of a Sipuleucel-T, Day (b) (4) processing for batch (b) (4) at workstation (b) (4): The (b) (4) and (b) (4) used in processing are not always completely sanitized (b) (4) moving from manufacturing module ISO (b) (4) environment to ISO (b) (4) Biological Safety Cabinet. The Operator (b) (6), (b) (7)(C) did not completely cover the surface at the bottom of the centrifuge (b) (4) and (b) (4) (b) (4) with (b) (4). D. On March 19, 2026, we observed the following deficiencies during the cell harvest operation of a Sipuleucel-T, Day (b) (4) processing for batch (b) (4) at workstation (b) (4): I. The operator (b) (6), (b) (7)(C) was observed entering and exiting the ISO (b) (4) biological safety cabinet (BSC) from the ISO (b) (4) environment without sanitizing hands with (b) (4) II. The operator (b) (6), (b) (7)(C) was observed entering and exiting the BSC quickly by (b) (4) (b) (4) while transferring materials into BSC without sanitizing hands with (b) (4). III. The operator (b) (6), (b) (7)(C) was observed leaving the ISO (b) (4) BSC and workstation (b) (4) for extended periods of time while the product was in the centrifuge. IV. After the setup, before and throughout the processing time, we observed an (b) (4), which appear to be like a (b) (4) on the (b) (4) the BSC in an ISO (b) (4) environment 2. Your firm's environmental monitoring program does not address the following: In-process monitoring of BSC on March 18, 2026, during Day (b) (4) manufacturing activities for Sipuleucel-T batch number (b) (4) did not include sampling of the (b) (4) of the BSC as per instructions in procedure SOP-11386.27 entitled "In-Process Environmental Monitoring at ...... Manufacturing Facilities", effective October 4, 2024. On March 18, 2026, it was observed that all (b) (4) Environmental Monitoring surface samples from the BSC were collected at the (b) (4) of the working surface of the Biologic Safety Cabinet (Equipment Number (b) (4)). Since August 4, 2023, to March 16, 2026, your firm has manufactured and distributed approximately (b) (4) batches of Sipuleucel-

      Shortened here; the PDF has the full text.

    2. Observation 4

      Quality unit failures for contract and research-use materials

      The responsibilities and procedures applicable to the quality control unit are not fully followed. A. Your firm uses a contract manufacturer to (b) (4) (b) (4) of your (b) (4). Your firm's quality control unit does not ensure that the final visual inspection for the (b) (4) solution is completed and acceptable for release. For example, your quality control unit did not document the reason for rejection provided by the contract manufacturer for the following and did not conduct investigations of the rejections. Your contract manufacturer rejected the following: 1. (b) (4) rejected (b) (4) (approximately 16% total batch) 2. (b) (4) rejected (b) (4) (approximately 8% of total batch) 3. (b) (4) rejected (b) (4) (approximately 30% of total batch) 4. (b) (4) rejected (b) (4) (approximately 99% of total batch) 5. (b) (4) rejected (b) (4) (approximately 34% of total batch) B. Your firm uses a (b) (4) with (b) (4) solution for manufacturing of your (b) (4). The information for use (71500870 AF V:6 09/2020) states "the products are intended for (b) (4) (b) (4) Where your procedures require sterile products, (b) (4)" However, your QC unit has not evaluated the risk of using this material, which is intended for research use only, to manufacture the (b) (4) Solutions. Since February 2024, your firm has manufactured approximately (b) (4) of (b) (4) and approximately (b) (4) of (b) (4). Of those manufactured (b) (4), approximately (b) (4) have been shipped to your sister location in Georgia. The (b) (4) solutions are used to (b) (4) the target cells during your Sipuleucel-T manufacturing process.

    3. Observation 5

      Deficient batch records and electronic record controls

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in processing and packing. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records. A. On March 17, 2026, it was observed that the workstation used in the manufacturing process have a (b) (4) to document in the electronic batch record for Sipuleucel-T manufacturing (Master Batch record number (b) (4). The (b) (4) make it potentially impossible to identify the employee that performed each step during manufacturing. Additionally, the Manager for Manufacturing Operations explained that (b) (4) verifier can assist (b) (4) workstations simultaneously performing manufacturing operations for Sipuleucel-T. B. The (b) (4) batch record does not contain detailed documentation describing the reason (b) (4) are rejected during filling and capping. For example: 1. (b) (4) had (b) (4) rejected due to "volume filling error," the batch record does not describe what the reason for the error was or how the error occurred. 2. (b) (4) had (b) (4) rejected due to "volume filling error," the batch record does not describe what the reason for the error was or how the error occurred. 3. (b) (4) had (b) (4) rejected due to "volume filling error," the batch record does not describe what the reason for the error was or how the error occurred. Since February 2024, your firm has manufactured approximately (b) (4) of (b) (4) and approximately (b) (4) of (b) (4). Of those manufactured (b) (4), approximately (b) (4) have been shipped to your sister location in Georgia. The (b) (4) solutions are used to (b) (4) the target cells during your Sipuleucel-T manufacturing process.

    4. Observation 6

      Unvalidated manufacturing process with unaddressed changes

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, since February 2024, your firm has manufactured (b) (4) and (b) (4), in house. A comparison study was conducted to demonstrate the comparability between your in-house manufacturing process and the prior contract manufacturer's process. Your current manufacturing process significantly differs from the contract manufacturer's process in the following parameters: I. Lot Size II. Mixing Conditions III. Hold times IV. Elimination of (b) (4) step V. Filling Environment ISO (b) (4) to ISO (b) (4) VI. Method of (b) (4) Sterilization VII. Different (b) (4) Composition The manufacturing validation and comparability study did not fully address the impact of the changes above. Your firm did not ensure the reproducibility and effectiveness of the manufacture of the (b) (4) solutions, (b) (4). Your (b) (4) are a critical component in your Sipuleucel-T manufacturing process as they are used to (b) (4) the target cells. Since February 2024, your firm has manufactured approximately (b) (4) of (b) (4) and approximately (b) (4) of (b) (4). Of those manufactured (b) (4), approximately (b) (4) have been shipped to your sister location in Georgia. The (b) (4) solutions are used to (b) (4) the target cells during your Sipuleucel-T manufacturing process.

    5. Observation 7

      Container change without leachables and stability evaluation

      Drug product (b) (4) are (b) (4) so as to alter the safety, identity, strength, quality, and purity of the drug beyond the official or established requirements. Specifically, since February 2024, your firm started using (b) (4) for the in-house manufacturing of (b) (4) instead of (b) (4) (b) (4) which were used by the CMO's formulation. However, your stability study with (b) (4) in the (b) (4) position does not evaluate potential leachable, extractables, and seal integrity or if the formulation degrades when in direct, long-term contact with the (b) (4) or (b) (4) over time.

    6. Observation 8

      Inadequate visual inspection training and qualification

      Employees engaged in the manufacture, processing and packing of a drug product lack the experience required to perform their assigned functions. Your firm's quality unit approved written procedure, SOP-10046.20, entitled "General Visual Inspection," effective June 13, 2025, outlines the training and qualification requirements for personnel performing visual inspections. The quality unit failed to provide documents and demonstrate visual inspection test kits or library of defective samples as part of visual inspection training for employees performing 100% visual inspection. Furthermore, your firm relies on visual inspection to ensure the following materials do not contain particulates and are acceptable for use in manufacturing of your Sipuleucel-T drug product: 1. 2. 3. 4. (b) (4) 5. 6. (b) (4) 7. 8.

    7. Observation 9

      Unapproved reprocessing without written procedure

      Reprocessing was performed without the review and approval of the quality control unit. Specifically, employees engaging in the manufacturing operation of your (b) (4) determines whether a (b) (4) should be reprocessed during packaging operations. Reprocessing can occur because of (b) (4), (b) (4), or incorrect color (b) (4). Furthermore, your firm does not have a written procedure for reprocess or rework. For example: a) (b) (4) Lot # (b) (4) had (b) (4) reprocessed inline during the packaging operation. b) (b) (4) Lot # (b) (4) had (b) (4) reprocessed inline during the packaging operation. c) (b) (4) Lot # (b) (4) had (b) (4) reprocessed inline during the packaging operation. There is no quality unit oversight for approval of reprocessing of the (b) (4).

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Rejecting When Specifications Not Met

      Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.

    2. Extent of discrepancy, failure investigations

      Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.

  3. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Rejected Material Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the holding of rejected components, drug product containers, closures and labeling before disposition.

    2. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established.

    3. Component addition checked by 2nd person

      Each component is not added to a batch by one person and verified by a second person.

    4. Incoming material area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the receipt, identification, storage, and withholding from use of pending sampling, testing, or examination by the quality control unit before release for manufacturing or packaging.

    5. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    Show 5 more citations
    1. Cleaning SOPs/schedules

      Procedures for the cleaning and maintenance of equipment are deficient regarding maintenance and cleaning schedules, including, where appropriate, sanitizing schedules.

    2. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

    3. Approval and review of procedures

      Written procedures are not reviewed and approved by the quality control unit.

    4. Documentation of Actual Yield and Theoretical Yield

      The batch production and control records are deficient in that they do not include a statement of the actual yield and percentage of theoretical yield.

    5. Equipment for Environmental Control

      Equipment for adequate control over temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

  4. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    2. Complete Test Data

      Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.

    3. Review of Adverse Experiences - SOPs

      There are no written procedures for the surveillance, receipt, evaluation and reporting of post-marketing adverse experiences to FDA.

    4. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

    5. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    Show 5 more citations
    1. Review of Adverse Experiences - promptness

      Adverse experience information is not promptly reviewed.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Labeling and packaging improperly approved/released

      Labeling and packaging materials not meeting the appropriate written specifications were released for use.

    4. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Three requests to FDA under the Freedom of Information Act named this site, most recently on Jul 7, 2026. Each one asked for a Form 483.

  • Inspection ending Mar 25, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jun 4, 2026FDA-FOIA-2026-5549Form 483· 1 of 5 sitesRecords released
  • Inspection ending Aug 10, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Oct 31, 2023FDA-FOIA-2023-9555Form 483Closed
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 on Jul 22, 2026. FDAgent holds no copy that FDA posted.

    1. Jul 7, 2026FDA-FOIA-2026-6469Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 14 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.

Show all 14

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Dendreon Pharmaceuticals LLCD-U-N-S 079879298

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Dendreon Pharmaceuticals LLC (D-U-N-S 079879298) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3008821247 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3008821247. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.