S.s.s. Company (international)
71 University Ave Sw, Atlanta, Georgia, United States
FEI 1012915DUNS 003288321
FDA has 7 inspections on file for S.s.s. Company (international) in Atlanta, Georgia (FEI 1012915), from 2009 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the three FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.100(a).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is S.S.S. Company (international) (D-U-N-S 003288321).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 7, 2009–2026
- 1 OAI · 5 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 7
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest Oct 15, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Component written specification
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Show 2 more citations
Written program not followed
The written stability testing program is not followed.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Laboratory equipment calibration records
Laboratory records do not include complete records of the periodic calibration of laboratory instruments.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written Procedures Not Followed
Written procedures are not followed for the identification, storage, and handling of drug product containers.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments, apparatus, gauges, and recording devices is not done at suitable intervals in accordance with an established written program.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Oct 15, 2026.
Inspection ending Jun 26, 2026OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 11, 2026. FDAgent holds no copy that FDA posted.
- Oct 15, 2026FDA-FOIA-2026-10043Form 483· 1 of 5 sitesOpen
- Aug 27, 2026FDA-FOIA-2026-8309Form 483· 1 of 5 sitesRecords released
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Aug 6, 2026FDA-FOIA-2026-7587EIRWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 7 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements3 of 5
- 21 CFR 211.100Written procedures; deviations2 of 5
- 21 CFR 211.194Laboratory records2 of 5
- 21 CFR 211.25Personnel qualifications1 of 5
- 21 CFR 211.80General requirements1 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 5
- 21 CFR 211.103Calculation of yield1 of 5
- 21 CFR 211.113Control of microbiological contamination1 of 5
Show all 11
- 21 CFR 211.125Labeling issuance1 of 5
- 21 CFR 211.166Stability testing1 of 5
- 21 CFR 211.192Production record review1 of 5
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- S.S.S. Company (international)D-U-N-S 003288321
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1012915 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1012915. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.