21 CFR 211.28: Personnel responsibilities
FDA's inspection data lists 311 Form 483 citations of 21 CFR 211.28 at 274 facilities, from November 2008 to February 5, 2026. 5 warning letters state a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 311
- At 306 inspections
- Facilities cited
- 274
- Distinct FEIs
- Most recent citation
- Feb 5, 2026
- NexCell Scientific Inc
- Warning letters
- 5
- State a violation of it
The regulation
The current text of 21 CFR 211.28 from the Electronic Code of Federal Regulations.
§ 211.28 Personnel responsibilities.
(a) Personnel engaged in the manufacture, processing, packing, or holding of a drug product shall wear clean clothing appropriate for the duties they perform. Protective apparel, such as head, face, hand, and arm coverings, shall be worn as necessary to protect drug products from contamination.
(b) Personnel shall practice good sanitation and health habits.
(c) Only personnel authorized by supervisory personnel shall enter those areas of the buildings and facilities designated as limited-access areas.
(d) Any person shown at any time (either by medical examination or supervisory observation) to have an apparent illness or open lesions that may adversely affect the safety or quality of drug products shall be excluded from direct contact with components, drug product containers, closures, in-process materials, and drug products until the condition is corrected or determined by competent medical personnel not to jeopardize the safety or quality of drug products. All personnel shall be instructed to report to supervisory personnel any health conditions that may have an adverse effect on drug products.
21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart BRead on eCFR
Citations by year
Form 483 citations of 21 CFR 211.28 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 56 in 2013
| Year | Form 483 citations |
|---|---|
| 2008 | 2 |
| 2009 | 7 |
| 2010 | 14 |
| 2011 | 13 |
| 2012 | 17 |
| 2013 | 56 |
| 2014 | 39 |
| 2015 | 56 |
| 2016 | 35 |
| 2017 | 17 |
| 2018 | 19 |
| 2019 | 12 |
| 2020 | 1 |
| 2021 | 4 |
| 2022 | 4 |
| 2023 | 3 |
| 2024 | 5 |
| 2025 | 6 |
| 2026 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 311 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Clothing appropriate for duties performed155 citations
- Protective Apparel Not Worn117 citations
- Habits of good sanitation & health30 citations
- Unauthorized Personnel in Limited Access Areas8 citations
- Excluding Employees with Illness, Lesions1 citations
Citation text
- “Protective apparel is not worn as necessary to protect drug products from contamination.”117 citations
- “Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.”45 citations
- “Production personnel were not practicing good sanitation and health habits.”30 citations
- “Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.”29 citations
Show 2 more
- “Clothing of personnel engaged in the manufacturing of drug products is not appropriate for the duties they perform.”21 citations
- “Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.”21 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 211.28, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Show 4 more
- Aspen SA Sterile Operations (Pty) Ltd.2024-09-17 · FEI 3007490529Clothing appropriate for duties performed
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.28 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 21 observations tie this way. The highlighted sentence is the matched wording.
Turbare Manufacturing2026-05-07 · Observation 3
Production personnel were not practicing good sanitation and health habits. Specifically, Your firm failed to establish and maintain adequate controls to prevent repeated objectionable microorganism recoveries during personnel monitoring (PM) activities in ISO Class 5 and ISO Class 7 classified areas. Environmental monitoring records document six (6) personnel monitoring excursion events involving bacterial contamination from …
This observation opens with FDA's standard wording for 21 CFR 211.28(b).
JKR Pharmacy Ventures, LLC2025-12-19 · Observation 4
Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform. Specifically, Your firm's pharmacy technicians operating in the ISO classified areas don scrubbs worn from home, a disposable non-sterile gown, a single non-sterile hair net, no eye protection, no face mask, and non-sterile shoe covers. Your firm's general gowning requirements allow …
This observation opens with FDA's standard wording for 21 CFR 211.28(a).
Sato Pharmaceutical Co., Ltd.2025-11-21 · Observation 10
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, your firm’s operators working in the Grade A and B areas are using goggles which have holes on the top that open directly to the outside (direct vent).
This observation opens with FDA's standard wording for 21 CFR 211.28(a).
Show 2 more
Ipca Laboratories Limited2023-06-23 · Observation 7
Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform. Specifically, personal gowning used in the compression areas is not maintained clean (b) (4) inspection of Dispensing Room and Compression Area used in the respective area appeared worn out and torn (with holes measuring more than 2 inches). It appeared soiled with black, white, (b) (4). In the core …
This observation opens with FDA's standard wording for 21 CFR 211.28(a).
New Era Pharmacy, LLC2019-11-27 · Observation 1
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, on 11/22/19, an employee was observed wearing a non-sterile face mask and a non-sterile knee-length gown. The non-sterile sleeves of his gown were inside the ISO 5 Biological Safety Cabinet during sterile production of HCG Microdose 1000 IU/10 mL (50 IU/0.5 mL) Injectable, Lot HM-1122S19, expiration date 12/6/19.
This observation opens with FDA's standard wording for 21 CFR 211.28(a).
Warning letters stating a violation of 21 CFR 211.28
5 warning letters FDA posted state a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your firm failed to ensure that manufacturing personnel wear clothing appropriate to protect drug product from contamination (21 CFR 211.28(a)).”
Each letter below states the violation in these words.
- Apothecary Pharma, LLCIssued 2025-12-01
- ProRx, LLCIssued 2025-03-04
- US Specialty Formulations, LLCIssued 2023-07-26
- Advanced Nutriceuticals, LLC dba The Guyer Institute of Molecular MedicineIssued 2021-11-10
- Infusion Options, Inc.Issued 2021-08-26
Often cited at the same inspection
Of the 306 inspections where FDA cited 21 CFR 211.28, the share where it also cited each of these sections.
- 21 CFR 211.113Control of microbiological contamination192 (63%)
- 21 CFR 211.42Design and construction features181 (59%)
- 21 CFR 211.166Stability testing134 (44%)
- 21 CFR 211.192Production record review126 (41%)
- 21 CFR 211.165Testing and release for distribution118 (39%)
- 21 CFR 211.67Equipment cleaning and maintenance108 (35%)
Ask FDAgent about 21 CFR 211.28
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.28; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.