Aspen SA Sterile Operations (Pty) Ltd.
8b Gibaud Road, Port Elizabeth, South Africa
FEI 3007490529
FDA has 6 inspections on file for Aspen SA Sterile Operations (Pty) Ltd. in Port Elizabeth, South Africa (FEI 3007490529), from 2012 to 2026. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the four FOIA requests for this site has asked FDA for this inspection's 483.
FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 6, 2012–2026
- 2 OAI · 2 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest Sep 11, 2026
- Warning letters
- · CDER ↗
- Import refusals
- 1 refusal
- Import alerts
- 66-40Red List
- Matched on FDA’s firm name and street address
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Calibration/Inspection/Checking not done
Routine checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, drug product containers, closures, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Clothing appropriate for duties performed
Clothing of personnel engaged in the manufacturing of drug products is not appropriate for the duties they perform.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Show 7 more citations
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written sanitation procedures lacking
There is a lack of written procedures describing in sufficient detail the methods, equipment and materials to be used for sanitation.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Sep 11, 2026.
Inspection ending Jul 14, 2026OAI
1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 30, 2026. FDAgent holds no copy that FDA posted.
- Sep 11, 2026FDA-FOIA-2026-8841Form 483Records released
Inspection ending Sep 17, 2024OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Feb 24, 2025FDA-FOIA-2025-1692Form 483Closed
Inspection date not given
2 requests. None of FDA’s log entries for these requests say records were released.
- Feb 20, 2025FDA-FOIA-2025-1600EIRWithdrawn
- Feb 20, 2025FDA-FOIA-2025-1599Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements3 of 3
- 21 CFR 211.28Personnel responsibilities2 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 3
- 21 CFR 211.100Written procedures; deviations2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.42Design and construction features1 of 3
- 21 CFR 211.56Sanitation1 of 3
Show all 12
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.111Time limitations on production1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.194Laboratory records1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007490529, one row per refused product line.
1 refusal on 2019-08-27 · charged REGISTERED on 1 · no FDA sample analysis
FDA firm profile- 2019-08-27
ACCESSORIES TO CONTACT LENSES - CLEANING AND WETTING AGENTS86LPN
REGISTERED 502(o), 801(a)(3); MISBRANDING
Division of Southeast ImportsT77-1541592-5/11/1
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov
Date published 2025-02-10
- FDA’s entry
- Aspen SA Sterile Operations (Pty) Ltd. · 8b Gibaud Road, Port Elizabeth, Eastern Cape SOUTH AFRICA
- FDA’s inspection record for FEI 3007490529
- Aspen SA Sterile Operations (Pty) Ltd. · 8b Gibaud Road, Port Elizabeth, South Africa
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
15 products
- 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
- 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
- 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
Show 12 more products
- 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
- 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 56 - - - --Antibiotics (Human/Animal)
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
- 60 - - - --Human and Animal Drugs
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3007490529 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3007490529. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.