FDA has 6 inspections on file for Aspen SA Sterile Operations (Pty) Ltd. in Port Elizabeth, South Africa (FEI 3007490529), from 2012 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the four FOIA requests for this site has asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

Four regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
6, 2012–2026
2 OAI · 2 VAI · 2 NAI
Inspections with 483 observations shown
3 of 6
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
4 requests, latest Sep 11, 2026
Import refusals
1 refusal
Import alerts
66-40Red List
Matched on FDA’s firm name and street address

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    3. Calibration/Inspection/Checking not done

      Routine checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, drug product containers, closures, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    2. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    3. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    4. Clothing appropriate for duties performed

      Clothing of personnel engaged in the manufacturing of drug products is not appropriate for the duties they perform.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    Show 7 more citations
    1. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    2. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    4. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    6. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    7. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written sanitation procedures lacking

      There is a lack of written procedures describing in sufficient detail the methods, equipment and materials to be used for sanitation.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    3. Protective Apparel Not Worn

      Protective apparel is not worn as necessary to protect drug products from contamination.

  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Four requests to FDA under the Freedom of Information Act named this site, most recently on Sep 11, 2026.

  • Inspection ending Jul 14, 2026OAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 30, 2026. FDAgent holds no copy that FDA posted.

    1. Sep 11, 2026FDA-FOIA-2026-8841Form 483Records released
  • Inspection ending Sep 17, 2024OAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Feb 24, 2025FDA-FOIA-2025-1692Form 483Closed
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. Feb 20, 2025FDA-FOIA-2025-1600EIRWithdrawn
    2. Feb 20, 2025FDA-FOIA-2025-1599Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.

Show all 12

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007490529, one row per refused product line.

1 refusal on 2019-08-27 · charged REGISTERED on 1 · no FDA sample analysis

FDA firm profile
  • 2019-08-27

    ACCESSORIES TO CONTACT LENSES - CLEANING AND WETTING AGENTS86LPN

    REGISTERED 502(o), 801(a)(3); MISBRANDING

    Division of Southeast ImportsT77-1541592-5/11/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2025-02-10

    FDA’s entry
    Aspen SA Sterile Operations (Pty) Ltd. · 8b Gibaud Road, Port Elizabeth, Eastern Cape SOUTH AFRICA
    FDA’s inspection record for FEI 3007490529
    Aspen SA Sterile Operations (Pty) Ltd. · 8b Gibaud Road, Port Elizabeth, South Africa

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    15 products

    • 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
    • 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
    • 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
    Show 12 more products
    • 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
    • 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3007490529 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3007490529. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.