Homeocare Laboratories, Inc.
7 Odell Plz Ste 142-146, Yonkers, New York, United States
FEI 3008420443DUNS 088248828
FDA has 5 inspections on file for Homeocare Laboratories, Inc. in Yonkers, New York (FEI 3008420443), from 2017 to 2024. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two FOIA requests have asked FDA for this inspection's 483.
FDA has issued 2 warning letters under this FEI, the latest on (CDER). No court action or import refusal is filed under this FEI.
11 regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and relabeling, through Dec 31, 2026. Its registrant is HomeoCare Laboratories Inc. (D-U-N-S 088248828).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 5, 2017–2024
- 4 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 5 of 5
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Apr 10, 2026
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established.
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Show 7 more citations
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, control and procedures.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
No written record of investigation
Written records are not always made of investigations into the failure of a batch or any of its components to meet specifications.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy.
Quarantine Storage of Components
Incoming components are not stored under quarantine until they have been tested or examined, as appropriate, and released.
Show 5 more citations
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Homeopathic drugs, assessment of stability
There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients and marketing experience with the drug product to indicate that there is no degradation of the product for the normal or expected period of use.
Identification of Equipment and Lines
The batch production and control records are deficient in that they do not include the identity of major equipment used.
Rejecting When Specifications Not Met
Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Incoming material area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the receipt, identification, storage, and withholding from use of components pending sampling, testing, or examination by the quality control unit before release for manufacturing or packaging.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Homeopathic drugs, assessment of stability
There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients.
Show 4 more citations
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Show 2 more citations
Following/documenting laboratory controls
Established test procedures are not followed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
Specific information required in individual logs
Individual equipment logs do not show time, date, product and lot number of each batch processed.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to review production records to assure that no errors have occurred.
Acceptance/Rejection Levels
The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels.
Approval and review of procedures
Written procedures are not reviewed and approved by the quality control unit.
Show 9 more citations
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Testing and standardization of standards et. al.
Laboratory records do not include complete records of any testing and standardization of laboratory.
Examinations documented
The results of the examination of the packaged and labeled products were not documented in the batch production or control records.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Apr 10, 2026. Each one asked for a Form 483.
Inspection ending Mar 20, 2024OAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 17, 2026. FDAgent holds no copy that FDA posted.
- Apr 10, 2026FDA-FOIA-2026-3611Form 483Records released
- Jul 30, 2024FDA-FOIA-2024-6619Form 483· 1 of 4 sitesClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 22 sections of 21 CFR in FDA’s published citations for this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.100Written procedures; deviations5 of 5
- 21 CFR 211.63Equipment design, size, and location4 of 5
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures4 of 5
- 21 CFR 211.160General requirements4 of 5
- 21 CFR 211.188Batch production and control records4 of 5
- 21 CFR 211.22Responsibilities of quality control unit3 of 5
- 21 CFR 211.67Equipment cleaning and maintenance3 of 5
- 21 CFR 211.165Testing and release for distribution2 of 5
Show all 22
- 21 CFR 211.166Stability testing2 of 5
- 21 CFR 211.180General requirements2 of 5
- 21 CFR 211.192Production record review2 of 5
- 21 CFR 211.198Complaint files2 of 5
- 21 CFR 211.25Personnel qualifications1 of 5
- 21 CFR 211.28Personnel responsibilities1 of 5
- 21 CFR 211.42Design and construction features1 of 5
- 21 CFR 211.56Sanitation1 of 5
- 21 CFR 211.82Receipt and storage of untested components, drug product containers, and closures1 of 5
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 5
- 21 CFR 211.134Drug product inspection1 of 5
- 21 CFR 211.182Equipment cleaning and use log1 of 5
- 21 CFR 211.186Master production and control records1 of 5
- 21 CFR 211.194Laboratory records1 of 5
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched some of these, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, relabeling
- Registration runs through
- Dec 31, 2026
- Registrant
- HomeoCare Laboratories Inc.D-U-N-S 088248828
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008420443 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008420443. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.