21 CFR 211.182: Equipment cleaning and use log
FDA's inspection data lists 324 Form 483 citations of 21 CFR 211.182 at 291 facilities, from November 2008 to July 13, 2026.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 324
- At 313 inspections
- Facilities cited
- 291
- Distinct FEIs
- Most recent citation
- Jul 13, 2026
- Conopco Inc. d/b/a Unilever
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 211.182 from the Electronic Code of Federal Regulations.
§ 211.182 Equipment cleaning and use log.
A written record of major equipment cleaning, maintenance (except routine maintenance such as lubrication and adjustments), and use shall be included in individual equipment logs that show the date, time, product, and lot number of each batch processed. If equipment is dedicated to manufacture of one product, then individual equipment logs are not required, provided that lots or batches of such product follow in numerical order and are manufactured in numerical sequence. In cases where dedicated equipment is employed, the records of cleaning, maintenance, and use shall be part of the batch record. The persons performing and double-checking the cleaning and maintenance (or, if the cleaning and maintenance is performed using automated equipment under § 211.68, just the person verifying the cleaning and maintenance done by the automated equipment) shall date and sign or initial the log indicating that the work was performed. Entries in the log shall be in chronological order.
21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart JRead on eCFR
Citations by year
Form 483 citations of 21 CFR 211.182 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 36 in 2010
| Year | Form 483 citations |
|---|---|
| 2008 | 4 |
| 2009 | 28 |
| 2010 | 36 |
| 2011 | 28 |
| 2012 | 34 |
| 2013 | 15 |
| 2014 | 17 |
| 2015 | 20 |
| 2016 | 18 |
| 2017 | 26 |
| 2018 | 21 |
| 2019 | 15 |
| 2020 | 4 |
| 2021 | 12 |
| 2022 | 8 |
| 2023 | 12 |
| 2024 | 12 |
| 2025 | 10 |
| 2026 | 4 |
How FDA words this citation
FDA's short descriptions and citation text on these 324 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Written records kept in individual logs222 citations
- Personnel dating/signing equipment log45 citations
- Specific information required in individual logs43 citations
- Dedicated equipment: records part of batch record9 citations
- Chronological Order of Equipment Log Entries5 citations
Citation text
- “Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.”124 citations
- “Written records of major equipment use are not included in individual equipment logs.”23 citations
- “Individual equipment logs do not show time, date, product and lot number of each batch processed.”22 citations
- “Written records of major equipment cleaning and use are not included in individual equipment logs.”20 citations
Show 2 more
- “Written records of major equipment maintenance and use are not included in individual equipment logs.”18 citations
- “The persons double-checking the cleaning and maintenance are not dating and signing or initialing the equipment cleaning and use log.”17 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 211.182, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Eurofins BioPharma Product Testing ENCO, LLC.2025-09-25 · FEI 3006067100Written records kept in individual logs
Show 4 more
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.182 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 1 observation ties this way. The highlighted sentence is the matched wording.
Lights Medical Manufacture Co Ltd2024-11-08 · Observation 2
Written records of major equipment use are not included in individual equipment logs. Specifically, Your firm does not maintain equipment use logs for equipment used in the manufacturing process of over-the-counter drug products. This includes, but is not limited to, the following equipment: Name of Manufacturing Equipment Equipment ID(s) [illegible]
This observation opens with FDA's standard wording for 21 CFR 211.182.
Often cited at the same inspection
Of the 313 inspections where FDA cited 21 CFR 211.182, the share where it also cited each of these sections.
- 21 CFR 211.22Responsibilities of quality control unit164 (52%)
- 21 CFR 211.67Equipment cleaning and maintenance151 (48%)
- 21 CFR 211.100Written procedures; deviations127 (41%)
- 21 CFR 211.160General requirements125 (40%)
- 21 CFR 211.192Production record review117 (37%)
- 21 CFR 211.188Batch production and control records116 (37%)
Ask FDAgent about 21 CFR 211.182
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
Topics that count this section:Data integrity,Equipment cleaning
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.182; FDAgent quotes that sentence exactly.