Skip to content

21 CFR 211.186: Master production and control records

FDA's inspection data lists 598 Form 483 citations of 21 CFR 211.186 at 474 facilities, from October 2008 to August 20, 2026. 1 warning letter states a violation of it.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
598
At 534 inspections
Facilities cited
474
Distinct FEIs
Most recent citation
Aug 20, 2026
CC Wellness, LLC
Warning letters
1
State a violation of it

The regulation

The current text of 21 CFR 211.186 from the Electronic Code of Federal Regulations.

§ 211.186 Master production and control records.

(a) To assure uniformity from batch to batch, master production and control records for each drug product, including each batch size thereof, shall be prepared, dated, and signed (full signature, handwritten) by one person and independently checked, dated, and signed by a second person. The preparation of master production and control records shall be described in a written procedure and such written procedure shall be followed.

(b) Master production and control records shall include:

(1) The name and strength of the product and a description of the dosage form;

(2) The name and weight or measure of each active ingredient per dosage unit or per unit of weight or measure of the drug product, and a statement of the total weight or measure of any dosage unit;

(3) A complete list of components designated by names or codes sufficiently specific to indicate any special quality characteristic;

(4) An accurate statement of the weight or measure of each component, using the same weight system (metric, avoirdupois, or apothecary) for each component. Reasonable variations may be permitted, however, in the amount of components necessary for the preparation in the dosage form, provided they are justified in the master production and control records;

(5) A statement concerning any calculated excess of component;

(6) A statement of theoretical weight or measure at appropriate phases of processing;

(7) A statement of theoretical yield, including the maximum and minimum percentages of theoretical yield beyond which investigation according to § 211.192 is required;

(8) A description of the drug product containers, closures, and packaging materials, including a specimen or copy of each label and all other labeling signed and dated by the person or persons responsible for approval of such labeling;

(9) Complete manufacturing and control instructions, sampling and testing procedures, specifications, special notations, and precautions to be followed.

21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceuticals, Subpart JRead on eCFR

Citations by year

Form 483 citations of 21 CFR 211.186 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 69 in 2010

Form 483 citations of 21 CFR 211.186 by inspection year
YearForm 483 citations
200810
200960
201069
201161
201261
201346
201437
201538
201638
201730
201832
201930
202013
202111
202217
202316
202415
202512
20262

How FDA words this citation

FDA's short descriptions and citation text on these 598 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Written procedures followed127 citations
  • Manufacturing Instructions and Specifications111 citations
  • Complete instructions, procedures, specifications et. al.107 citations
  • Signature and checking of records -- 2 persons105 citations
  • Description of containers, labels, et. al.47 citations
Show 3 more
  • Theoretical yield statement including percentages34 citations
  • Master production and control records, procedure16 citations
  • Theoretical Yield and Percentages13 citations

Citation text

  • “The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.”79 citations
  • “Procedures for the preparation of master production and control records are not described in a written procedure.”65 citations
  • “Master production and control records lack complete manufacturing and control instructions.”36 citations
  • “Procedures for the preparation of master production and control records are not described in a written procedure and followed.”36 citations
Show 2 more
  • “Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required.”31 citations
  • “Procedures for the preparation of master production and control records are not followed.”25 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 211.186, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

  • CC Wellness, LLC2026-08-20 · FEI 3013395518Manufacturing Instructions and Specifications
  • Genuine Virgin Aloe Corp2026-08-14 · FEI 3008235829Complete instructions, procedures, specifications et. al.
  • Spartan Chemical Co Inc2025-11-21 · FEI 3001451695Description of containers, labels, et. al.
  • Simtra Deutschland GmbH2025-09-26 · FEI 3002806419Written procedures followed
  • Fareva Amboise2025-09-16 · FEI 3000234005Written procedures followed
  • BSO, LLC2025-06-27 · FEI 3030548360Manufacturing Instructions and Specifications
Show 4 more
  • Hysan Pharmaceutical Co., Ltd.2025-06-12 · FEI 3004087499Master production and control records, batch uniformity
  • Catalent Ontario Limited2025-05-02 · FEI 3007325436Complete instructions, procedures, specifications et. al.
  • Innocore Sales & Marketing Inc.2025-04-25 · FEI 3010034070Description of containers, labels, et. al.
  • KVK Tech, Inc.2025-03-14 · FEI 3005117563Manufacturing Instructions and Specifications

What the observations say

Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 211.186 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 10 observations tie this way. The highlighted sentence is the matched wording.

  • Catalent Indiana LLC2026-04-24 · Observation 7

    Master production and control records lack complete manufacturing and control instructions. Specifically, The work instruction A-WI-22-06-001-001 titled "Packaging and Labeling Defect Criteria List" that is utilized to assist the Quality Unit in identifying drug product defects during AQL inspections of finished sterile drug product batches is void of detailed critical and major (b)(4) defect descriptions, such as but not limited to the …

    This observation opens with FDA's standard wording for 21 CFR 211.186(b)(9).

  • RAYZEBIO INC2026-02-24 · Observation 11

    Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required. Specifically, The master batch record for the products (b)(4) Solution for infusion does not have theoretical yield specifications at final dilution stage of the drug product.

    This observation opens with FDA's standard wording for 21 CFR 211.186(b)(7).

  • Aurobindo Pharma Limited, Unit VII2026-02-10 · Observation 3

    Master production and control records lack complete manufacturing and control instructions, sampling and testing procedures. Specifically, A. During the inspection it was observed that the compression operations do not include designated fields to record that stratified samples are collected during the compression run. This documentation prevents verification throughout the compression run that the stratified samples were collected …

    This observation opens with FDA's standard wording for 21 CFR 211.186(b)(9).

Show 2 more
  • BSO, LLC2025-06-27 · Observation 6

    The master production and control records are deficient in that they do not include complete manufacturing and control instructions, specifications, special notations and precautions to be followed. Specifically, a. Inadequate Documentation and Control: The Estradiol Granulate Production- Batch Production Record (Form 45-09E) does not record the [illegible] parameters setpoint applied during the [illegible] step and that it was maintained …

    This observation opens with FDA's standard wording for 21 CFR 211.186(b)(9).

  • Piramal Pharma Limited2025-02-17 · Observation 5

    Master production and control records lack complete manufacturing and control instructions, written specifications, and precautions to be followed. Specifically, A. Section 8.18 of the Master Batch Manufacturing Record (BMR) of Crude (b)(4) requires the operator to (b)(4) [illegible]. However, MBR [illegible] allows [illegible] cycles per the MBR instructions. In addition, the (b)(4) step has greyed start and end time sections and …

    This observation opens with FDA's standard wording for 21 CFR 211.186(b)(9).

Warning letters stating a violation of 21 CFR 211.186

1 warning letter FDA posted states a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.

“Your firm failed to establish and follow written procedures for the preparation of master production and control records designed to assure uniformity from batch to batch. Your firm also failed to prepare batch production and control records with complete information relating to the production and control of each batch of drug product produced (21 CFR 211.186(a) and 211.188).”

Often cited at the same inspection

Of the 534 inspections where FDA cited 21 CFR 211.186, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 211.186

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

Topics that count this section:Data integrity

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 211.186; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.