Piramal Pharma Limited
Midc, C - 43 Ttc Industrial Area; Thane Belapur Road, Navi Mumbai, India
FEI 3008763768DUNS 650515294
FDA has 4 inspections on file for Piramal Pharma Limited in Navi Mumbai, India (FEI 3008763768), from 2011 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. Four of the five FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is Piramal Pharma Limited (D-U-N-S 650515294).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2011–2025
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 4
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 5 requests, latest Jul 10, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit procedures not documented
OBSERVATION 1 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. On February 11th, 2025, I conducted a walkthrough of Room [illegible] used to [illegible]. Approximately 1:10 pm, I observed liquid present throughout the floor of the Room and visually leaking from the adjacent (b)(4) vessel. (b)(4) was used to store the (b)(4) material. (b)(4) was also used for [illegible] and [illegible] Batch No (b)(4). No operator or supervisor was present in the room at the time the observed incident. According to the Site Head, the operator responsible for stopping [illegible] (b)(4) unit had gone to lunch and the leaking was likely due to the gasket on the (b)(4) vessel coming loose. However, there was no documentation of the operator activity or his presence within the room. In addition, the equipment logbook nor line clearance checklist include a check for the (b)(4) vessel gasket. Lastly, the (b)(4) time frame is not defined or appropriately documented within the equipment usage logbooks or associated activity form. B. On February 11th, 2025, I conducted a walkthrough of the (b)(4) production area and the associated Production Office. I observed that dispensing material weigh sheets and Line Clearance Checklist of Dispensing of Raw Materials associated with (b)(4) (non-U.S. API product), Batch No (b)(4), were stored directly between pages of executed batch manufacturing record (BMR). The Production Officer responsible for [illegible] stated that he recently signed affected records for (b)(4) steps involving Crude and raw material dispensing steps for Batch No (b)(4). C. The [software/equipment name redacted] used to control and monitor the step for APIs had the following alarms reported throughout (b)(4) batches between October 24, 2024 - December 25, 2024: [illegible list]. However, there was no investigation or documented explanation as to why the (b)(4) gauge alarm and [illegible] alarm remained present and unacknowledged for multiple hours throughout the API batch (b)(4) process. In addition, the equipment alarms have not been challenged as part of Installation, Operation, and Performance Qualification (IQ/OQ/PQ). D. The software used to control and monitor the [illegible] process step for APIs had the following alarms reported throughout Batch # [illegible] (API batch processed between February 08, 2025, and February 11, 2025): (b)(4) 1. Approximately six (6) (b)(4) alarms; 2. One (1) (b)(4) alarm; 3. Approximately eleven (11) (b)(4) warning alarms; 4. Approximately two (2) (b)(4) warning alarms. However, there was no investigation or documented explanation as to why the alarms remained present and unacknowledged for multiple hours throughout the API batch (b)(4) process. The vendor Operating Instructions manual categorizes alarms as Type 1: Stop the device. In addition, the equipment alarms have not been challenged as part of Installation, Operation, and Performance Qualification (IQ/OQ/PQ).
- Observation 2
Investigations lack adequate follow-up
OBSERVATION 2 Written records of investigation of an active pharmaceutical ingredient (API) do not include follow-up. Specifically, A. Four (4) deviations were reported between March 06 - March 18, 2024, for [illegible] (b)(4) 09, due to the steps of (b)(4) batches being stuck. The first incident occurred on March 06, 2024, for (b)(4) Batch No. (b)(4). The second incident occurred on March 09, 2024, for (b)(4) Batch No. (b)(4). The third incident occurred on March 12, 2024, for (b)(4) Batch No. (b)(4), and the fourth incident occurred on March 17, 2024 for Batch No. [illegible] which was reprocessed into [illegible]. The following deficiencies were noted concerning the deviations: 1. There is no documented quality risk assessment performed to determine continued manufacturing operations of subsequent batches on the same (b)(4) [illegible] while the investigation remained open for the deviation involving batch (b)(4). 2. There was no investigation report opened at the time incident involving (b)(4) Batch No. (b)(4) cycle being stuck at Step No. (b)(4) on March 09, 2024. Batch No. (b)(4) was documented as being manufactured after the decision to manufacture the next batch Batch No. [illegible], Start Date: March 12, 2024, with the same equipment. Batch No. (b)(4) subsequently had the similar reported deviation on March 15, 2024. 3. There is no documentation of service/engineering activities and maintenance checks required to be performed after the repeated (b)(4) issues involving Batch No. (b)(4) and Batch No. (b)(4). 4. Batch No. [illegible] and Batch No. [illegible] have not been evaluated for stability throughout batch product expiry despite deviation from the validated (b)(4) process and (b)(4) specification. The (b)(4) deviated to approximately [illegible]. B. Deviation RDV/LA-22-023 was initiated on May 23, 2022 due to the [illegible] activities for (b)(4) at cell [illegible] and therefore being manually promoted to step No. 1 of the (b)(4) process between May 22 - 24, 2022. According to the investigation, a variation of its [illegible] may impact water content and [illegible] content. Batch No. (b)(4) Retest Date: April 2025 was released to the U.S. market on (b)(4) after having passing yield and quality results for purity, assay, and water content. However, the batch was not monitored for stability throughout its API Retest Date, despite deviation from the validated (b)(4) process and (b)(4) specification.
Show observations 3 to 6
- Observation 3
Complaint investigation lacked testing
OBSERVATION 3 Written records of investigation of an API complaint do not include adequate follow-up. Specifically, Customer Complaint CC-22-06 was initiated on May 21, 2022, for foreign particles being observed for [illegible] Batch No. [illegible], Retest Date: May 2024. Samples from another API batch, Batch No. (b)(4), was used to test traces of potential foreign/metallic particles. However, there was no documented attempt to retrieve and test the customer complaint sample. In addition, retention samples of the sample batch were not tested. According to the Quality Control Head, there were not enough retention samples available to test the sample complaint batch. This is despite (b)(4) units of samples for Batch No. (b)(4) being documented as retained within the Control of Sample Register at the time of the investigation. However, there is no documented reasoning as to how the control sample size necessary to conduct the complaint investigation was determined. According to SOP CIC/QA/11 Handling of Customer Complaints, Version 10, Effective Date: February 22, 2022, Section 5.5, the Quality Control unit must examine the retain sample of the complaint batch and check for physical parameters. In addition, compare the retain sample with the sample, if received along with the complaint.
- Observation 4
Inadequate cleaning validation for equipment
OBSERVATION 4 The cleaning of equipment is inadequate. Specifically, A. Cleaning procedures have not been validated for shared equipment used to manufacture and process crude APIs for the U.S. and other global markets. For example, the following shared equipment have not been evaluated as part of a cleaning validation program: 1. (b)(4) was used for (b)(4) step involving (b)(4) activity Date: December 31, 2024 to January 02, 2025, and December 28, 2024 to December 31, 2024. The same batch (b)(4) was previously used for (b)(4) step involving (b)(4) Activity Date: December 25, 2024 to December 26, 2024. 2. (b)(4) was used for (b)(4) step involving (b)(4) activity Date: November 28, 2024 to December 01, 2024, and November 27 - 28, 2024. The same was also previously used for (b)(4) step involving (b)(4) Batch No. (b)(4) Activity Date: November 24, 2024 to November 25, 2024. 3. (b)(4) was used for (b)(4) activity Date: October 12, 2024 to October [illegible]. (b)(4) was also previously used for (b)(4) activity Date: October 07, 2024 to October 13, 2024. 4. (b)(4) was used involving (b)(4) Activity Date: September 26, 2024 - September 28, 2024. The same was also previously used for (b)(4) involving (b)(4) activity Date: September 19 - 20, 2024 and Batch No. (b)(4) Activity Date: September 16 - 18, 2024. B. During the inspection walkthrough on February 11th, 2025, I observed a material [illegible] based material stored directly within the (b)(4) vessel of (b)(4). (b)(4) was most recently used to process Batch No. [illegible]. During the inspection, the Site Head and QA Head identified the material as (b)(1) for (b)(4) used during (b)(4) operations of the previous batch. However, (b)(4) was documented as being cleaned within the Batch Equipment Cleaning Record (BECR) and had a clean equipment status completed on: February 10, 2025, and valid up until (b)(4).
- Observation 5
Incomplete master production records
OBSERVATION 5 Master production and control records lack complete manufacturing and control instructions, written specifications, and precautions to be followed. Specifically, A. Section 8.18 of the Master Batch Manufacturing Record (BMR) of Crude (b)(4) requires the operator to (b)(4) [illegible]. However, MBR [illegible] allows [illegible] cycles per the MBR instructions. In addition, the (b)(4) step has greyed start and end time sections and checked by sections. Therefore, operators are not able to appropriately document the cycle start and end time. For example: 1. The executed BMR for Crude (b)(4) Batch No. (b)(4) included documentation of [illegible] cycles instead of the [illegible] instructed by the master BMR. No written deviation has been initiated for the change in the validated procedure. 2. The executed BMR for Crude Batch No. (b)(4) included the following written remark on the back page: "End time column is shaded hence end time written in remark column." 3. The executed BMR for Crude Batch No. (b)(4) included the following written remark on the back page: "End time of (b)(4) has recorded in remark Column. End time Column is shaded." B. Operators are required to perform [illegible] as per the Master Batch Manufacturing Record (BMR) of Crude (b)(4). However, Version 03 (Effective Date: December 14, 2024) of the master BMR has greyed out the Start and End Time sections and Checked By sections for (b)(4) steps. Executed BMRs do not include documentation of [illegible] step requiring [illegible] time.
- Observation 6
Improper storage and contamination risk
OBSERVATION 6 There is a failure to handle and store components, key starting materials, API containers, and closures at all times in a manner to prevent contamination and ensure satisfactory conformance to the identity and strength of each active ingredient. A. According to the Site Head and QA Head, Key Starting Materials (KSMs) used to manufacture APIs for the U.S. market and that are labelled with frozen and refrigerated storage label requirements are shipped and received at the firm via room temperature conditions. This includes the following KSMs transported at room temperature for multiple days (more than 24 hours) and shipped without any assurance of cold chain custody: (b)(4). B. On February 11th, 2025, I observed (b)(4) foreign matter within the (b)(4) API Batch No. held within (b)(4) vessel (b)(4). During the inspection, the matter was isolated from the (b)(4) and sent for external laboratory testing. The identification testing demonstrated that the foreign matter originated from the [illegible] use processing activities.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Five requests to FDA under the Freedom of Information Act named this site, most recently on Jul 10, 2026. Each one asked for a Form 483.
Inspection ending Feb 17, 2025VAI
4 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 10, 2026FDA-FOIA-2026-6615Form 483· 1 of 4 sitesRecords released
- Jul 24, 2025FDA-FOIA-2025-9090Form 483· 1 of 3 sitesClosed
- Jun 18, 2025FDA-FOIA-2025-7775Form 483· 1 of 10 sitesWithdrawn
- Feb 20, 2025FDA-FOIA-2025-1618Form 483· 1 of 2 sitesClosed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Feb 20, 2025FDA-FOIA-2025-1614Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Piramal Pharma LimitedD-U-N-S 650515294
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other FEIs recorded as Piramal Pharma Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Piramal Pharma LimitedFEI 3003803288Kohir Mandal, Sangareddy District, India
Last inspected 2026-02-13VAI
Piramal Pharma LimitedFEI 3005259207Pithampur, India
Last inspected 2023-05-19NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008763768 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008763768. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.