Piramal, Piramal Pharma Limited Form 483, February 2025
FDA issued this Form 483 to Piramal, Piramal Pharma Limited in Navi Mumbai, India (FEI 3008763768) at the end of a drug inspection that ended February 17, 2025. It lists 6 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 6, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Feb 17, 2025
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Mar 6, 2025
- 17 days after the inspection
The 6 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Quality unit procedures not documented
OBSERVATION 1 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. Specifically, A. On February 11th, 2025, I conducted a walkthrough of Room [illegible] used to [illegible]. Approximately 1:10 pm, I observed liquid present throughout the floor of the Room and visually leaking from the adjacent (b)(4) vessel. (b)(4) was used to store the (b)(4) material. (b)(4) was also used for [illegible] and [illegible] Batch No (b)(4). No operator or supervisor was present in the room at the time the observed incident. According to the Site Head, the operator responsible for stopping [illegible] (b)(4) unit had gone to lunch and the leaking was likely due to the gasket on the (b)(4) vessel coming loose. However, there was no documentation of the operator activity or his presence within the room. In addition, the equipment logbook nor line clearance checklist include a check for the (b)(4) vessel gasket. Lastly, the (b)(4) time frame is not defined or appropriately documented within the equipment usage logbooks or associated activity form. B. On February 11th, 2025, I conducted a walkthrough of the (b)(4) production area and the associated Production Office. I observed that dispensing material weigh sheets and Line Clearance Checklist of Dispensing of Raw Materials associated with (b)(4) (non-U.S. API product), Batch No (b)(4), were stored directly between pages of executed batch manufacturing record (BMR). The Production Officer responsible for [illegible] stated that he recently signed affected records for (b)(4) steps involving Crude and raw material dispensing steps for Batch No (b)(4). C. The [software/equipment name redacted] used to control and monitor the step for APIs had the following alarms reported throughout (b)(4) batches between October 24, 2024 - December 25, 2024: [illegible list]. However, there was no investigation or documented explanation as to why the (b)(4) gauge alarm and [illegible] alarm remained present and unacknowledged for multiple hours throughout the API batch (b)(4) process. In addition, the equipment alarms have not been challenged as part of Installation, Operation, and Performance Qualification (IQ/OQ/PQ). D. The software used to control and monitor the [illegible] process step for APIs had the following alarms reported throughout Batch # [illegible] (API batch processed between February 08, 2025, and February 11, 2025): (b)(4) 1. Approximately six (6) (b)(4) alarms; 2. One (1) (b)(4) alarm; 3. Approximately eleven (11) (b)(4) warning alarms; 4. Approximately two (2) (b)(4) warning alarms. However, there was no investigation or documented explanation as to why the alarms remained present and unacknowledged for multiple hours throughout the API batch (b)(4) process. The vendor Operating Instructions manual categorizes alarms as Type 1: Stop the device. In addition, the equipment alarms have not been challenged as part of Installation, Operation, and Performance Qualification (IQ/OQ/PQ).
- 2
Investigations lack adequate follow-up
OBSERVATION 2 Written records of investigation of an active pharmaceutical ingredient (API) do not include follow-up. Specifically, A. Four (4) deviations were reported between March 06 - March 18, 2024, for [illegible] (b)(4) 09, due to the steps of (b)(4) batches being stuck. The first incident occurred on March 06, 2024, for (b)(4) Batch No. (b)(4). The second incident occurred on March 09, 2024, for (b)(4) Batch No. (b)(4). The third incident occurred on March 12, 2024, for (b)(4) Batch No. (b)(4), and the fourth incident occurred on March 17, 2024 for Batch No. [illegible] which was reprocessed into [illegible]. The following deficiencies were noted concerning the deviations: 1. There is no documented quality risk assessment performed to determine continued manufacturing operations of subsequent batches on the same (b)(4) [illegible] while the investigation remained open for the deviation involving batch (b)(4). 2. There was no investigation report opened at the time incident involving (b)(4) Batch No. (b)(4) cycle being stuck at Step No. (b)(4) on March 09, 2024. Batch No. (b)(4) was documented as being manufactured after the decision to manufacture the next batch Batch No. [illegible], Start Date: March 12, 2024, with the same equipment. Batch No. (b)(4) subsequently had the similar reported deviation on March 15, 2024. 3. There is no documentation of service/engineering activities and maintenance checks required to be performed after the repeated (b)(4) issues involving Batch No. (b)(4) and Batch No. (b)(4). 4. Batch No. [illegible] and Batch No. [illegible] have not been evaluated for stability throughout batch product expiry despite deviation from the validated (b)(4) process and (b)(4) specification. The (b)(4) deviated to approximately [illegible]. B. Deviation RDV/LA-22-023 was initiated on May 23, 2022 due to the [illegible] activities for (b)(4) at cell [illegible] and therefore being manually promoted to step No. 1 of the (b)(4) process between May 22 - 24, 2022. According to the investigation, a variation of its [illegible] may impact water content and [illegible] content. Batch No. (b)(4) Retest Date: April 2025 was released to the U.S. market on (b)(4) after having passing yield and quality results for purity, assay, and water content. However, the batch was not monitored for stability throughout its API Retest Date, despite deviation from the validated (b)(4) process and (b)(4) specification.
- 3
Complaint investigation lacked testing
OBSERVATION 3 Written records of investigation of an API complaint do not include adequate follow-up. Specifically, Customer Complaint CC-22-06 was initiated on May 21, 2022, for foreign particles being observed for [illegible] Batch No. [illegible], Retest Date: May 2024. Samples from another API batch, Batch No. (b)(4), was used to test traces of potential foreign/metallic particles. However, there was no documented attempt to retrieve and test the customer complaint sample. In addition, retention samples of the sample batch were not tested. According to the Quality Control Head, there were not enough retention samples available to test the sample complaint batch. This is despite (b)(4) units of samples for Batch No. (b)(4) being documented as retained within the Control of Sample Register at the time of the investigation. However, there is no documented reasoning as to how the control sample size necessary to conduct the complaint investigation was determined. According to SOP CIC/QA/11 Handling of Customer Complaints, Version 10, Effective Date: February 22, 2022, Section 5.5, the Quality Control unit must examine the retain sample of the complaint batch and check for physical parameters. In addition, compare the retain sample with the sample, if received along with the complaint.
- 4
Inadequate cleaning validation for equipment
OBSERVATION 4 The cleaning of equipment is inadequate. Specifically, A. Cleaning procedures have not been validated for shared equipment used to manufacture and process crude APIs for the U.S. and other global markets. For example, the following shared equipment have not been evaluated as part of a cleaning validation program: 1. (b)(4) was used for (b)(4) step involving (b)(4) activity Date: December 31, 2024 to January 02, 2025, and December 28, 2024 to December 31, 2024. The same batch (b)(4) was previously used for (b)(4) step involving (b)(4) Activity Date: December 25, 2024 to December 26, 2024. 2. (b)(4) was used for (b)(4) step involving (b)(4) activity Date: November 28, 2024 to December 01, 2024, and November 27 - 28, 2024. The same was also previously used for (b)(4) step involving (b)(4) Batch No. (b)(4) Activity Date: November 24, 2024 to November 25, 2024. 3. (b)(4) was used for (b)(4) activity Date: October 12, 2024 to October [illegible]. (b)(4) was also previously used for (b)(4) activity Date: October 07, 2024 to October 13, 2024. 4. (b)(4) was used involving (b)(4) Activity Date: September 26, 2024 - September 28, 2024. The same was also previously used for (b)(4) involving (b)(4) activity Date: September 19 - 20, 2024 and Batch No. (b)(4) Activity Date: September 16 - 18, 2024. B. During the inspection walkthrough on February 11th, 2025, I observed a material [illegible] based material stored directly within the (b)(4) vessel of (b)(4). (b)(4) was most recently used to process Batch No. [illegible]. During the inspection, the Site Head and QA Head identified the material as (b)(1) for (b)(4) used during (b)(4) operations of the previous batch. However, (b)(4) was documented as being cleaned within the Batch Equipment Cleaning Record (BECR) and had a clean equipment status completed on: February 10, 2025, and valid up until (b)(4).
- 5
Incomplete master production records
OBSERVATION 5 Master production and control records lack complete manufacturing and control instructions, written specifications, and precautions to be followed. Specifically, A. Section 8.18 of the Master Batch Manufacturing Record (BMR) of Crude (b)(4) requires the operator to (b)(4) [illegible]. However, MBR [illegible] allows [illegible] cycles per the MBR instructions. In addition, the (b)(4) step has greyed start and end time sections and checked by sections. Therefore, operators are not able to appropriately document the cycle start and end time. For example: 1. The executed BMR for Crude (b)(4) Batch No. (b)(4) included documentation of [illegible] cycles instead of the [illegible] instructed by the master BMR. No written deviation has been initiated for the change in the validated procedure. 2. The executed BMR for Crude Batch No. (b)(4) included the following written remark on the back page: "End time column is shaded hence end time written in remark column." 3. The executed BMR for Crude Batch No. (b)(4) included the following written remark on the back page: "End time of (b)(4) has recorded in remark Column. End time Column is shaded." B. Operators are required to perform [illegible] as per the Master Batch Manufacturing Record (BMR) of Crude (b)(4). However, Version 03 (Effective Date: December 14, 2024) of the master BMR has greyed out the Start and End Time sections and Checked By sections for (b)(4) steps. Executed BMRs do not include documentation of [illegible] step requiring [illegible] time.
- 6
Improper storage and contamination risk
OBSERVATION 6 There is a failure to handle and store components, key starting materials, API containers, and closures at all times in a manner to prevent contamination and ensure satisfactory conformance to the identity and strength of each active ingredient. A. According to the Site Head and QA Head, Key Starting Materials (KSMs) used to manufacture APIs for the U.S. market and that are labelled with frozen and refrigerated storage label requirements are shipped and received at the firm via room temperature conditions. This includes the following KSMs transported at room temperature for multiple days (more than 24 hours) and shipped without any assurance of cold chain custody: (b)(4). B. On February 11th, 2025, I observed (b)(4) foreign matter within the (b)(4) API Batch No. held within (b)(4) vessel (b)(4). During the inspection, the matter was isolated from the (b)(4) and sent for external laboratory testing. The identification testing demonstrated that the foreign matter originated from the [illegible] use processing activities.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.