Aurobindo Pharma Limited, Unit VII
India
FEI 3007373532DUNS 650381903
Company: Aurobindo Pharma Limited · Linked by exact D-U-N-S match (650082092) in FDA registration data
FDA has 8 inspections on file for Aurobindo Pharma Limited, Unit VII in India (FEI 3007373532), from 2009 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 9 observations from the PDF; they are listed below. One of the four FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Sep 27, 2019. 1 import refusal is filed under this FEI, on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Aurobindo Pharma Limited (D-U-N-S 650082092), has registered 5 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 8, 2009–2026
- 1 OAI · 2 VAI · 4 NAI
- Inspections with 483 observations shown
- 3 of 8
- Requested under FOIA
- 4 requests, latest FY2023
- Warning letters
- None on file
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 9 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate cleaning and HEPA maintenance
OBSERVATION 1 Equipment and utensils are not cleaned at appropriate intervals to prevent identity, strength, quality or purity of the drug product. Specifically, A. The (b)(4) non-dedicated (b)(4) (b)(4) drug products cleaned since their installation several years ago. For example, (b)(4) ID No.: installation On 28-Jan-2026, we observed build-up on Filter and its (b)(4) and throughout the (b)(4). The (b)(4) oc:ite (b)(4) through the (b)(4) EPAr filter materials into the (b)(4) and contaminate the equipment. Usage status of these (b)(4) on 28-Jan-2026 These are used in the manufacturing of the (b)(4) at varying strengths that are sold into the USA (b)(4). On 29-Jan-2026, your firm collected multiple swabs from (b)(4) HEPA filter duct and analyzed swab samples for chemical analysis by APCL method to identify the presence of substances and related degradants of the previously manufactured products. Presence of different drug substances observed in verification/cleaning validation indicating a potential risk for drug products cross-contamination with other component product active materials (drug substances) that were manufactured using the (b)(4). Examples (HPLCs) are tabulated as follows: Table 4 (HPLC Acceptance Limit) Results of (b)(4) Sampling location (Analyses Date 29/01/26) The swab analysis results were found as high as approximately (b)(4) times the acceptance limit. Table 5 (HPLC Acceptance Results) Sampling location (Analyses Date 29/01/26) (b)(4) The swab analysis results were found as high as approximately 380 times the acceptance limit. Table 6 Acceptance Limit Results of (b)(4) Sampling location (Analyses Date 29/01/26) (b)(4) Following the swab sample chemical test results, on 30-Jan-2026 your firm reported Field Alerts for (b)(4) block. On 05-Feb-2026, your firm collected additional (b)(4) for chemical analyses and an HPLC test method (APL/GT/0026-01) was used. These swab samples show potential for carryover and cross-contamination between these non-dedicated (b)(4) examples. Table 7 (HPLC Acceptance Limit: (b)(4)) The swab analysis results were found as high as approximately 545 times (Table 8 (HPLC Acceptance) (b)(4)). Additionally, the swab sample test results (Tables 4 to 8) indicate the swab stick could not adsorb/retain large amount X (b)(4) surface area that was swabbed for each swab. Furthermore, swab sample testing of (b)(4) refer eluting at different retention times in multiple peaks not identified and accounted for in the above tables due to active and degradant materials of drug substances. 2. On 28-Jan-2026, we observed potential for growth due to bird droppings and layers of dust particles inside the (b)(4) ID: (b)(4). We also observed (b)(4) filter (b)(4) with (b)(4) % filter efficiency and (b)(4) of this (b)(4). On 29-Jan-2026, your Microbiologists collected (b)(4) from section of (b)(4) HEPA filter (b)(4). Microbial tests for count, fungal, mold, yeast, and total viable microorganisms were performed. Microbial test plate method results: TAMC: TNTC TYMC: Growth Observed Pseudomonas Aeruginosa: Growth Observed Staphylococcus Aureus: Whitish and yellow colonies observed. Pink colonies with yellow zone Salmonella: observed on (b)(4) Escherichia coli (E. coli): Whitish Pink mucoid colonies observed. TYMC: Total Yeast and Mold Count TAMC: Total Aerobic Microbial Count The evaluation of confirmatory testing results for Salmonella and transfer to the media as it was seen for positive control plate questioned testing integrity while performing microbial testing. B. Your Preventative Maintenance (PM) program: 1. Your procedure SOP No.: FU7-EN-MNP-007, "PREVENTATIVE MAINTENANCE PROGRAMME", Version: 15.0, Effective (date redacted) assigns responsibilities on the physical verification of overall conditions of (b)(4). Your Quality Unit failed to evaluate conditions. Engineering unit simply focused on following the (b)(4) without recognizing the excessive (b)(4) materials present inside areas of (b)(4) HEPA fil
Shortened here; the PDF has the full text.
- Observation 2
Production system access and records deficient
PRODUCTION SYSTEM OBSERVATION 2 Appropriate controls are not exercised over computer system access, and production and control records or other records are instituted only by authorized personnel. Specifically, A. Multiple (b)(4) empty trial runs were observed between production runs during the review of LU2J-LU.C4 backup data for (b)(4) with no documented explanation. Batch record instruction: empty trial runs were not recorded within the (b)(4) batch and audit trail reports were generated for Jul 6th, 2023: File Name Product Name (b)(4). There is no documented reasoning for the need to perform multiple empty trial runs between lots of the same campaign batch manufactured approximately (b)(4). B. According to the Associate Vice President (b)(4) Production Office (Room No. (b)(4)), reports of product on equipment involved printed reports are signed off and then attached. An unplugged computer system was observed. According to the Senior Executive of Production, the production password for the department is shared. In addition, the production personnel can permanently delete files from the computer recycle bin. There is reasoning for production officers to have deletion controls and access to additional applications, including a raster graphics editor for image creation and editing. In addition, the Human Machine Interface (HMI) panel in the production office displayed multiple copy jobs logged between dates. According to the Associate Vice President, he is unable to retrieve the documents (2025 vs. 2022) due to software limitations. C. The Industrial Panel Computer (IPC) of the (b)(4) zone used to manage, generate, and print production reports was observed to have permissions for deleting files in the recycle bin. There is no documented explanation of permissions for deleting files, recycle bin capability, and access to additional applications, including for: 1. Raster graphics editor for image creation; 2. Creating digital notes directly. D. Your firm utilizes Electrolab Trust E Model dissolution instrument as control laboratory for the dissolution testing. The instrument is capable of storing up to 10,000 methods. On January 28, 2026, it was observed that electronic test reports for dissolution tests conducted on January 28, 2026 were not available. The following AR numbers from dissolution runs were missing from the stored reports: 1. A.R. No. (b)(4) dissolution test was performed; 2. A.R. No. (b)(4) dissolution test was performed; 3. A.R. No. (b)(4) dissolution test was performed; 4. A.R. No. (b)(4) dissolution test was performed. According to your instrumentation engineer, the system may overwrite previous results. This practice creates a significant risk of loss of critical analytical data required for product release. Your firm has failed to implement adequate procedures for backing up analytical data from these dissolution apparatuses. E. During the review of the dissolution analytical package for (b)(4) it was observed that your employee shared their login credentials to perform dissolution test runs. Sharing login credentials compromises traceability of analytical data, as it becomes impossible to determine which individual performed the testing and reviewed the results. Examples where employees shared their login credentials include, but are not limited to: 1. A.R. No. (b)(4) dissolution test was performed on (date redacted); 2. A.R. No. (b)(4) dissolution test was performed on January 23, 2026, using instrument ID: DISZ0041; 3. A.R. No. (b)(4) dissolution test was performed on December (date redacted) using instrument ID: DISZ0041. F. On January 29, 2026, the Executive of (b)(4) observed on the desktop of the weighing balance integration system IPC a login ID used by packaging personnel. There is no documented rationale for packaging personnel to share user login IDs and passwords.
Show observations 3 to 9
- Observation 3
Incomplete master production records
OBSERVATION 3 Master production and control records lack complete manufacturing and control instructions, sampling and testing procedures. Specifically, A. During the inspection it was observed that the compression operations do not include designated fields to record that stratified samples are collected during the compression run. This documentation prevents verification throughout the compression run that the stratified samples were collected and that adequate process control was maintained. The calculation for the stratified sampling is not recorded. The following are examples of batch records (b)(4). B. According to the AVP of Quality Assurance, determining the rate at which the (b)(4) of the (b)(4) process involves the (b)(4) limit. Master batch record instructions do not define the (b)(4) and rate at which production personnel are allowed to changeover between the qualified operational set-ups for batches of (b)(4) Tablet (b)(4) for the U.S. market.
- Observation 4
Complaint records missing follow-up
QUALITY SYSTEM OBSERVATION 4 Complaints records are deficient in that they do not include the findings, conclusions, or corrective actions taken, including follow-up. Specifically, A. Approximately 52 out of 127 (≈41%) complaints consisted of (b)(4) received for (b)(4) and six (6) in 2025, Expiry Date: (b)(4) involving the following issues: 1. (issue redacted); 2. (issue redacted); 3. Difficulty separating blister units; 4. Poor perforation quality; 5. Loose in packaging. However, the following deficiencies were observed during the current inspection for USP (b)(4) mcg and during review of the complaint file for (b)(4) Malfunction (b)(4). For (b)(4) USP (b)(4) mcg, Batch No. (b)(4), 2026: 1. There have been no shipment studies to assess physical stresses, such as vibrations, shocks, temperature fluctuations, and pressure changes that do not compromise the (b)(4) functionality, integrity, and performance during transit. 2. No drop test study has been performed to evaluate packaging and functionality of the drug product. 3. No detailed risk assessment was performed for (b)(4) products, including assessment of risk mitigation strategies (e.g., corrective actions, mitigation effectiveness, and management approval). 4. No benchmarking against similar products for public data of performance. 5. As part of May 2022 (b)(4), samples were collected from (b)(4); however, there was no statistical justification for selection and sample pool. B. Customer Complaint No. APL-FU7-2024-USA-PCM-00105 for "Something metallic inside the pill" for (b)(4) Batch No. (b)(4) was received by your U.S. site for further evaluation and testing. However, there was no attempt to perform further identification or chemical analysis. The material embedded in the tablet was instead identified as lubricant from the compression machine punches. A blurry photo with crushed tablets on a paper was provided to conclude the lack of foreign material as part of the investigation. The same tablet, when subsequently crushed and photographed, appeared (b)(4) instead of (b)(4). There is a lack of investigation outsourced to your U.S. site. C. According to the General Manager of Management of Product Complaints, there is a minimum of (b)(4) follow-up attempts required. Version 1.0, Effective Date: October 23, 2025. However, there is no documented explanation for the lack of adequate follow-up for the following complaints involving lack of effect: Complaint Number APL-FU7-2026-USA-PCM-00009: (b)(4) tablets (b)(4) mg (details redacted). There were only (b)(4) follow-up attempts. The complaint investigation was closed approximately (time redacted) without documented explanation. Complaint Number APL-FU7-2025-USA-PCM-00503: (b)(4) tablets USP (b)(4) mg. There were only (b)(4) follow-up attempts and the complaint investigation was closed without documented explanation. Complaint Number APL-FU7-2025-USA-PCM-0207: (b)(4) tablet (b)(4) g, Batch Number: (b)(4). There were only (b)(4) out of the (b)(4) required follow-up attempts. The investigation was closed on July 21, 2025, without documented explanation. Complaint Number APL-FU7-2025-USA-PCM-00431: (b)(4) tablet 1.5 mg, Batch Number: (b)(4). There were only (b)(4) out of the (b)(4) required follow-up attempts. The investigation was closed on October 04, 2025, without documented explanation.
- Observation 5
Failure to investigate / monitor stability
OBSERVATION 5 There is a failure to thoroughly review any unexplained discrepancy and the failure to ensure that components and drug product meet any of its specifications whether or not the batch has been already distributed. Specifically, A. Your Quality Unit lacks adequate oversight for trending and investigations. For example, your firm fielded (b)(4) Tablets (b)(4) mg (batches redacted) due to (b)(4) detected above the Acceptable Intake (Al) limit when initially analyzed in (b)(4). An upward trend of higher results (borderline results) was observed at a time point in (b)(4) which suggests they will become out of specification prior to expiration, but your Quality Unit continued to accept analyses. Product Name/Strength Batch Number Acceptable Intake (Al) Limit (values redacted). The above batches (Table 10) were on stability with planned (b)(4) and the firm was planning to conduct (b)(4) analysis after the batch expiry in (b)(4). There is a lack of timely investigation. B. Your stability sample management and testing program is deficient. Your global procedure APL-GP-F-QC-GEN-0001, Titled: "Stability Studies", Version 3.0.0.0, Effective date: 09-Oct-2025 does not have a requirement for testing batches within stipulated timeline in your procedure. Therefore, delaying testing of batches on long term and accelerated stability conditions by multiple finished product batches on stability led to continued stability studies post expiry and no final stability timepoint defined for either (b)(4). There were multiple products and batches that required additional investigations and appropriate regulatory notification. On 09-Feb-2026, it was observed that about (b)(4) batches were beyond the final required testing time point relative to batch manufacturing date. There is potential for batch failure identified causing subpotent drug products to be distributed which could result in Lack of Efficacy (LOE) and Adverse Events (AE) for the products distributed in the market. C. On January 30th, 2026, it was observed that IPQA had signed off on completing Batch Record verification checkpoints without actually completing all the required review line items, including Step (redacted) with specification; Step (redacted) Data entry in Process pad is completed; Step (redacted) approved; and Step No. (redacted) All the investigations/PNC items were not completed for the following batch records: 1. (b)(4); 2. (b)(4); 3. (b)(4); 4. (b)(4). D. Released and Approved Batch Production Record (BPR) for (b)(4) No. (b)(4) Mfg. Date: February 2025, Expiration Date: (b)(4) had multiple blank and unused checklist copies attached. There is no documented reasoning for the page requests that remain blank in the approved BPR. This includes: 1. Two (2) open blank copies for Type C Cleaning Work Sheet FU7-PR-MF-CLN-009. 2. Four (4) open blank copies for Checklist for Area Clearance. Reference SOP: FU7-PR-GEN-005. E. According to the Document Requisition log, Document product development batch copy from the Document Storage and Retrieval area, copies of the same form were instead present in the (b)(4) Block. According to the log, the required number of copies was overlooked and only (1) required copy was present.
- Observation 6
Lack of Quality Unit oversight
OBSERVATION 6 The responsibilities and procedures applicable to cleaning, maintenance, and oversight are not adequately followed. Specifically, Your Quality Unit lacks adequate oversight. A. Microbiologists responsible for (b)(4) sampling: On 02-Feb-2026, we verified (b)(4) from multiple sampling locations in the suites. It was observed that Microbiologists took more swab samples than what they reported in their previous logs and failed to collect samples from sampling locations in the reported time. They entered manufacturing rooms with (b)(4) gowning. Additionally, they attempted to collect (b)(4) samples but did not record the reported time of collection. Even after multiple attempts, (b)(4) samples were recorded at times that did not match the actual collection. According to your (b)(4) collection procedure, (b)(4) swabs should be collected in sampling bottles. On 02-Feb, (b)(4) from the sampling locations of Zone (b)(4) with sections of the adjacent (b)(4) and the tablets compression room (b)(4) USP (b)(4) mg. The operators working inside tablets compression room continued to keep working with their (b)(4) shoe cover and gowning. During the interview, Microbiologists stated that they have (procedures redacted) while collecting (b)(4) samples and there was no investigation initiated, no risk assessment performed, and no corrective action taken.
- Observation 7
Insufficient GMP training frequency
OBSERVATION 7 GMP training is not conducted on a continuing basis with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to their assigned duties. Specifically, Review of your training program revealed significant deficiencies. Specifically, it was observed that from November (year redacted) training documents were pending completion. Your procedure Document Number APL-GEN-0010: Training Program, dated: December 18, 202-1, Section 2.5.2, employees (text redacted) training issuance.
- Observation 8
Deficient laboratory records and backdating
LABORATORY CONTROL SYSTEM OBSERVATION 8 Laboratory records are deficient in that they do not include complete recording of data from testing. Specifically, A. On January 28, 2026, during the walkthrough of (b)(4) Block H4 it was observed that multiple documents had dates that did not correspond to the actual date of the activity. The documents revealed that none of the documents had the date of that day. All the documents had dates of January (date redacted). An employee informed the investigators that he did not backdate any documents, yet another employee admitted he performs some backdating of documents. This backdating is inconsistent with proper record keeping. Examination of Finished Product: (b)(4) A.R. No. (b)(4). B. Your standalone Electrolab Trust E Model dissolution instrument stores electronic test reports for each dissolution run. These test reports should include the AR Number, Lot Number and sampling times as per your written procedure FU7-QC-CI-OPI-0148: Operation of Electrolab, Model: Trust - EDT-14LY, Version: 2.0.0.0. Effective (date redacted). Information was not included in the electronic test reports as observed while reviewing the analytical package. Examples: 1. The dissolution data package for (b)(4) A.R. No.: (b)(4) recorded the start time as (time redacted) but the electronic test report shows the dissolution was pulled at (time redacted). The electronic data indicated a discrepancy of approximately (value redacted) minutes from the specified test duration. 2. The dissolution data package for (b)(4) A.R. No.: (b)(4) recorded the start time as (time redacted) but the electronic test report shows the dissolution start time was pulled at (time redacted). The electronic data indicated a discrepancy of approximately (value redacted) minutes from the specified test duration. Additionally, in both dissolution runs it was observed that the (b)(4) samples are under investigation. Your procedure FU7-QC-CI-OPI-088: Operation (text redacted) requires investigation of such discrepancies.
- Observation 9
Laboratory control mechanisms not followed
OBSERVATION 9 Established laboratory control mechanisms are not followed. Specifically, During the walkthrough inspection of the (b)(4) laboratory it was observed where employees were not following written procedures. A. According to section 4.3 of the Description/Characteristics Version 1.0.0, plate reading should be conducted by an analyst from the (b)(4) observing the details in (b)(4) against (b)(4). An analyst was observed observing tablets through blister packaging (b)(4) Tablets USP (b)(4) Number (redacted). Further investigation revealed background setup issues extending across (b)(4) and ships more than (b)(4) products in different conditions. This reveals approximately 50 complaints related to (b)(4). B. On January 28, 2026, it was observed that microbiology plate reading in (b)(4) was not conducted according to Operation of Colony Counter, Version 3.0.0.0. Deviations from established procedures were observed: 1. First, your microbiologist conducted plate reading with condensation present which can obscure colony visualization and lead to inaccurate enumeration. The microbiologist failed to visually check for minute colonies as required by the procedure. 2. Second, your reviewer verified the results from the colony counter and prevented proper verification step. This improper handling technique compromised the verification step, which is critical for ensuring accurate enumeration. 3. Third, colony counter ID: COLB0 (redacted) lacked adequate visualization and enumeration capability, creating risk to detect all microbial colonies present. DATES OF INSPECTION 01/28/2026 (Wed), 01/29/2026 (Thu), 01/30/2026 (Fri), 02/05/2026 (Thu), 02/06/2026 (Fri), 02/09/2026 (Mon) The observations of objectionable conditions are reported pursuant to Section 704(b) of the Federal Food, Drug, and Cosmetic Act. Upon completion of any such inspection, the inspector shall prepare a written report setting forth any conditions or practices observed during the inspection which may constitute violations of the Act or applicable regulations. A copy of such report shall be sent promptly to the Secretary.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Written program not followed
The written stability testing program is not followed.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Show 1 more citation
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Invalidated OOS investigations
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, your firm's investigations were found to be deficient in that the Out of Specification (OOS) results have been invalidated for various tests without identifying scientifically sound and justifiable root causes. Human errors and instrument error have been attributed as major potential root causes and passing retest results have been reported. Our review of your OOS Investigations during the period beginning January 2017 until September 2019 revealed the following for U.S. marketed products: Category Total OOS Total Invalidated % Invalidated * [illegible table entries] Examples include, but are not limited to, the following investigations: (A) OOS Investigation FUSTOOS190024 for (b)(4) Tablets (b)(4) mg batches (b)(4) was initiated on 04/29/2019 to investigate Assay failures during the 3M stability testing (25°C/60%RH). The investigation suspected incorrect sonication time as the probable root cause. Based on this assumption, 5 hypothesis studies were initiated using [illegible] 4 mins sonication without intermittent shaking, and the last hypothesis study for [illegible] 8 mins sonication with intermittent shaking (i.e. as per STP instructions). The initial failing results and hypothesis results are as follows: Batch No. [illegible] Assay [illegible] [illegible] Specification [illegible] Hypothesis Study 1 Hypothesis-1A (5) mins [ED] Hypothesis-1B [illegible] mins Hypothesis-1C [illegible] mins Hypothesis-1D [illegible] mins Hypothesis-2 [illegible] mins (per STP). We were unable to determine if the hypothesis studies were actually conducted. Specifically, our review indicated that all associated analytical worksheets for the purported hypothesis studies have the same sonication time of [illegible] minutes. The analytical worksheets were reviewed and approved by the QC and QA personnel. We were unable to ascertain how the low Assay values were obtained for hypothesis studies. All four impacted batches covered in this investigation are currently in the U.S. market. (B) OOS Investigation FU7STOOS190023 for [illegible] USP [illegible] mg was initiated on 04/25/2019 to investigate the OOS results [illegible] % for the related Compound [illegible] against a specification limit of NMT [illegible] % (w/w) found during Related Substance testing at the 9-month time point (25°C/60%RH, batch #[illegible]). The investigation concluded human error caused by the use of a contaminated beaker with [illegible]. During the extended laboratory investigation, two hypothesis studies were conducted: experiment 1 using an intentionally contaminated beaker with [illegible], and experiment 2 as per STP requirement. Experiment 1 yielded [illegible] % for the related Compound [illegible] whereas experiment 2 yielded [illegible] % for the same impurity. However, no pH measurement of the original sample solution was considered to confirm the presence of [illegible] in the sample. The firm also referenced the product’s forced degradation study which was conducted with [illegible] that yielded a value of [illegible] for the same impurity. It is unclear how the firm utilized the degradation study performed with [illegible] to draw an equivalent conclusion with an unknown concentration of [illegible] during the hypothesis study. (C) OOS Investigation FU7STOOS190044 for [illegible] Tablets [illegible] mg, batch #[illegible] was initiated on 07/29/2019 to investigate the OOS results found during the 3-month stability testing (25°C/60%RH). The OOS results were obtained during the Organic Impurity testing (by HPLC). Specifically, [illegible] yielded OOS results of [illegible] % (w/w) and [illegible] % (w/w) against a specification limit of NMT [illegible] % (w/w) for the impurity. The subsequent investigation concluded that the root cause is due
Shortened here; the PDF has the full text.
- Observation 2
Undocumented / unaccounted batch records
There are no written procedures for production and process controls designed to assure that the drug products have identity, strength, quality, and purity they purport or are represented to possess. Specifically, (A) We observed the presence and use of executed batch manufacturing records that were not identified in the records presented during the inspection. When requested for the complete list of executed batches for (b)(4) Capsules [illegible] mg and [illegible] mg [illegible] your firm provided a list of [illegible] full batches (each involving stages) of which 3 of them were submission batches. The Vice President of Quality stated that no additional batches were made other than the batches included on the list. However, review of the firm's record management system (Data Storage and Retrieval System) audit trail showed that additional batch records have been issued and executed. For example, the following issued batch records were not included in the provided list but shown in the audit trail: [illegible entries] According to the firm's electronic records, approximately [illegible] additional batch records for this product have been issued but not executed. The BE application for [illegible] Capsules [illegible] mg and [illegible] mg is currently under review by the FDA. (B) Review of the re-issuance of records maintained by the Quality Assurance department indicated more than 100 logged events of batch record (or related documents) issuance in an uncontrolled Excel Sheet. The reasons for re-issuance identified in the file was either 'server is down', 'half pages downloaded', 'due to printer error', etc. However, several records have remained unaccounted for and the firm was unable to provide any record of reconciliation during the inspection. In addition, the destruction records maintained by the QA department do not include any printed/unexecuted batch records. Examples of unaccounted documents include batch records, protocols, etc. For example: • Batch record (b)(4) Capsules, USP (b)(4) mg [illegible] • Batch record (b)(4) Tablets, USP [illegible] • Batch record BRSA18053-A [illegible] Capsules, USP [illegible] [illegible footer lines]
Show observations 3 to 4
- Observation 3
Deficient process validation controls
Control procedures are not established which of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, (A) Your approach to commercial process validation (PV) is deficient. Several examples were found where either the first attempted commercial validation batches have failed, or commercial batches following the validation campaigns have intermittently failed. Since 2017, approximately [illegible] products have failed the initial commercial PV attempt. This include approximately 41 PV batches that were rejected purportedly with a root cause, and 3 PV batches rejected without any assignable root cause. Your approach to process performance qualification lacks adequate process understanding and demonstrable control. A few examples of U.S. marketed products where either the initial process validation batches failed or during subsequent post-validation commercial campaigns that failed are: 1. [illegible] Tablets USP [illegible] mg (first 3 commercial batches failed) 2. [illegible] Tablets USP [illegible] mg (4 PV batches failed) 3. [illegible] Tablets USP [illegible] mg (2 post validation commercial batches failed) 4. (b)(4) Capsules USP (1 post validation (b)(4) batch failed) (B) The sample quantities used to establish [illegible] hold time are not representative of the bulk [illegible] batch sizes. For example, the sample quantity used to establish hold time for several (b)(4) products is approximately (8) grams irrespective of the batch size. This approach was utilized by the firm in establishing bulk hold time for approximately (b)(4) products intended for the U.S. market.
- Observation 4
Incomplete laboratory audit trail data
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. Specifically, Review of the electronic audit trails from the Tiamo software application that operates Auto titrators / Karl-Fischer titrators indicated repeated events of 'Determination stopped', 'Determination reprocessed', 'Determination interrupted' and 'Determination error' during the progress of test runs. For example, during the test runs, the following incidents were observed between April 2018 and September 2019: Number of Times Stopped | Number of Times Error Message | Number of Times Interruption | Number of Times Reprocessed [illegible instrument log table entries: KFAZ0002, KFAZ0003, KFAZ0004, KFAZ0006, KFAZ0007, KFAZ0008, POAZ0001 with various counts] The 'Determination error' message included events such as Communication lost with device. However, your quality unit did not periodically review these audit trails and assess what may have caused these events. You also failed to investigate what those interruptions are and why the analysts may have stopped during a run. Some of the products that were running during this purported communication loss include, but are not limited to, (b)(4) USP, (b)(4) USP, (b)(4) USP, (b)(4) USP, (b)(4) Capsules, (b)(4) Capsules, [illegible] Capsules.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.
Inspection ending Feb 10, 2026Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Feb 11, 2026FDA-FOIA-2026-1441Form 483Records released
Inspection ending May 10, 2022VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- FY2023FDA-FOIA-2022-8987Form 483Closed
- Sep 1, 2022FDA-FOIA-2022-6315Form 483Closed
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- May 17, 2022FDA-FOIA-2022-3586Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 8 inspections.
- 21 CFR 211.63Equipment design, size, and location1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
- 21 CFR 211.192Production record review1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3007373532, one row per refused product line.
1 refusal on 2022-11-09 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2022-11-09
SUMATRIPTAN SUCCINATE (ANTIMIGRAINE AGENT)63OCT07
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsES9-0007488-3/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Aurobindo Pharma LimitedD-U-N-S 650082092
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Aurobindo Pharma Limited (D-U-N-S 650082092) as the registrant for this site and the 5 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Aurobindo Pharma LimitedSangareddy, India · FEI 30040212635 inspections5latestSep 29, 2023VAI1 warning letter, May 20, 2011
- APL HEALTHCARE LIMITEDTirupati, India · FEI 30118954105 inspections5latestDec 17, 2025VAINone on file
- Aurobindo Pharma LimitedMedchal, India · FEI 30044463128 inspections8latestSep 5, 2025OAINone on file
- Aurobindo Pharma LimitedMedchal, India · FEI 300402122912 inspections12latestJul 21, 2023VAINone on file
- Auro Central Testing LaboratoryTelangana, India · FEI 3048141588Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3007373532 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3007373532. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.