Aurobindo Pharma Limited
Unit-VI, Chitkul Village, Patancheru Mandal, Sy. No.329/39 & 329/47, Sangareddy, India
FEI 3004021263DUNS 918917639
Company: Aurobindo Pharma Limited · Linked by exact D-U-N-S match (650082092) in FDA registration data
FDA has 5 inspections on file for Aurobindo Pharma Limited in Sangareddy, India (FEI 3004021263), from 2010 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Dec 22, 2010. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Aurobindo Pharma Limited (D-U-N-S 650082092), has registered 5 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2010–2023
- 1 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 5
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 2 requests, latest Apr 6, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 2 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate production/process procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. Specifically, Exception no.’s APL-FU6-EXC-15-0031 issued on 5/5/15 and APL-FU6-EXC-15-0031 issued on 5/7/15 in response to customer complaints reporting the presence of black particles in the drug product containers, later determined to be desiccant®® failed to include adequate detail and instruction for performing the following: 1. [illegible] 2. The usage of the®@ 3. 100% Visual inspection for defects of the®® and adequate operator verification. Additionally, your firm's investigation into the cause of these complaints identified ®® of the the®@ [illegible] on the®® equipment as the most likely cause of the damaged®® Beginning on 5/7/15 this same piece of equipment continued to be used in the ®® of the®® desiccant [illegible] as stated in item 2 above followed by a 100% visual inspection. On 12/28/15 a complaint regarding presence of black particles (desiccant) was received for @@ Tablets USP ®®mg lot no. ©) under complaint no. CU06715-U06. To date, your firm has received a total of 20 customer complaints related to this issue across [illegible] finished product lots including®® Tablets USP ®® mg lot no ®@ exp. May 2018.
- Observation 2
Insufficient process validation controls
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. Specifically, Validation of the ®® hold time for ®@ Tablets USP @@ mg completed as part of process validation batch numbers®@ reported a maximum® ® hold time of ®@ However the®® hold time of ®® Tablet batches manufactured between September 2015 and April 2017 exceeded this®®@ — validated®® hold time. Similarly, validation of the ®® hold time for®® Suspension USP®®@ mg@ml, completed as part of process validation batch numbers®® reported a maximum ®@ hold time of ®®@ However the®® hold time of ®® Suspension batches manufactured between September 2015 and August 2017 exceeded this®®@ validated®® hold time.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate standards designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Show 2 more citations
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all components, drug product containers, closures, packaging material, and labeling.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Apr 6, 2026. Each one asked for a Form 483.
Inspection ending Sep 29, 2023VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Nov 28, 2023FDA-FOIA-2023-10637Form 483 + EIRClosed over fees
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Apr 21, 2026. FDAgent holds no copy that FDA posted.
- Apr 6, 2026FDA-FOIA-2026-3387Form 483· 1 of 2 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.198Complaint files1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Aurobindo Pharma LimitedD-U-N-S 650082092
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Aurobindo Pharma Limited (D-U-N-S 650082092) as the registrant for this site and the 5 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Aurobindo Pharma LimitedIndia · FEI 30073735328 inspections8latestFeb 10, 2026None on file
- APL HEALTHCARE LIMITEDTirupati, India · FEI 30118954105 inspections5latestDec 17, 2025VAINone on file
- Aurobindo Pharma LimitedMedchal, India · FEI 30044463128 inspections8latestSep 5, 2025OAINone on file
- Aurobindo Pharma LimitedMedchal, India · FEI 300402122912 inspections12latestJul 21, 2023VAINone on file
- Auro Central Testing LaboratoryTelangana, India · FEI 3048141588Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3004021263 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3004021263. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.