Skip to content

Baxter Oncology GmbH

Kant Str. 2, Halle (Westf.), Germany

FEI 3002806419DUNS 344276063

Company: Bamboo US BidCo LLC · Linked by exact D-U-N-S match (119087615) in FDA registration data

FDA has 11 inspections on file for Baxter Oncology GmbH in Halle (Westf.), Germany (FEI 3002806419), from 2010 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 12 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three of the 11 FOIA requests for this site have asked FDA for this inspection's records.

5 import refusals are filed under this FEI, the latest on . No court action is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.113(b), 21 CFR 211.192 and 21 CFR 211.42(c)(10)(iv).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling, analysis, sterilization and particle size reduction, through Dec 31, 2027. Its registrant, Bamboo US BidCo LLC (D-U-N-S 119087615), has registered 1 other site.

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
11, 2010–2025
1 OAI · 4 VAI · 6 NAI
Inspections with 483 observations shown
2 of 11
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
11 requests, latest Apr 28, 2026
Import refusals
5 refusals
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 12 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin.

    2. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.

    Show 7 more citations
    1. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.

    2. Authority lacking to review records, investigate errors

      The quality control unit lacks authority to review production records to assure that no errors have occurred.

    3. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.

    6. Written procedures followed

      Procedures for the preparation of master production and control records are not followed.

    7. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Equipment for Environmental Control

      Equipment for adequate control over air pressure and micro-organisms is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.

    2. Product flow through building is inadequate

      The flow of drug product containers though the building is not designed to prevent contamination.

    3. Habits of good sanitation & health

      Production personnel were not practicing good sanitation and health habits.

    4. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    5. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    Show 2 more citations
    1. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  10. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  11. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  12. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

11 requests to FDA under the Freedom of Information Act named this site, most recently on Apr 28, 2026.

  • Inspection ending Sep 26, 2025OAI

    3 requests. In the inspection history above. FDA has posted its Form 483.

    1. Apr 28, 2026FDA-FOIA-2026-4207Form 483Records released
    2. Jan 30, 2026FDA-FOIA-2026-911Form 483Records released
    3. Jan 14, 2026FDA-FOIA-2026-488Inspection recordsRecords released
  • Inspection ending Aug 27, 2024

    3 requests. Not listed in FDA’s Data Dashboard yet. FDA has posted its Form 483.

    1. Oct 31, 2025FDA-FOIA-2025-12496Form 483Records released
    2. Apr 4, 2025FDA-FOIA-2025-3099Form 483Closed
    3. Mar 12, 2025FDA-FOIA-2025-2272Form 483Closed
  • Inspection ending May 3, 2023NAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its EIR on Oct 27, 2025. FDAgent holds no copy that FDA posted.

    1. Oct 31, 2025FDA-FOIA-2025-12495Form 483Records released
    2. Aug 20, 2025FDA-FOIA-2025-10016EIRRecords released
  • Inspection date not given

    3 requests. FDA released records in answer to a request for its Form 483 on Oct 21, 2025. FDAgent holds no copy that FDA posted.

    1. Jan 27, 2026FDA-FOIA-2026-794Form 483 + EIRWithdrawn
    2. Oct 1, 2025FDA-FOIA-2025-11518Form 483Records released
    3. Dec 10, 2018FDA-FOIA-2018-9939Form 483Open

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 11 inspections, with how many of them cited each.

Show all 13

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002806419, one row per refused product line.

5 refusals from 2022-04-14 to 2024-07-11 · charged UNAPPROVED on 3, NOT LISTED on 2 · no FDA sample analysis

FDA firm profile
  • 2024-07-11

    ENZYME INHIBITOR N.E.C.64FIZ99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsKH5-4149876-3/21/1

  • 2024-07-11

    PENTOSTATIN (ANTI-NEOPLASTIC)62IIL92

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northeast ImportsKH5-4149876-3/11/1

  • 2023-12-01

    MONOCLONAL ANTIBODIES, N.E.C.64OIZ99

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Northern Border Imports231-8256709-5/11/1

  • 2022-04-14

    MENOTROPINS (GONAD-STIMULATING PRINCIPLE)64MDY05

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Northern Border ImportsAEK-0928632-7/31/1

  • 2022-04-14

    UROFOLLITROPIN (GONAD-STIMULATING PRINCIPLE)64MDY10

    NOT LISTED 502(o), 801(a)(3); MISBRANDING

    Division of Northern Border ImportsAEK-0928632-7/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, API manufacturing, packing, labeling, analysis, sterilization, particle size reduction
Registration runs through
Dec 31, 2027
Registrant
Bamboo US BidCo LLCD-U-N-S 119087615

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Bamboo US BidCo LLC (D-U-N-S 119087615) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

  • Simtra US LLCBloomington, Indiana · FEI 100011557117 inspections17latestSep 24, 2024VAINone on file

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3002806419 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3002806419. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.