Turbare Manufacturing
Arkansas
FEI 3027507354
FDA has 3 inspections on file for Turbare Manufacturing in Arkansas (FEI 3027507354), from 2025 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection and has since removed it.
The most recent OAI inspection ended on Jan 24, 2025. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 3, 2025–2026
- 1 OAI · 0 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 3
- 1 with citations published, text not held
- Requested under FOIA
- 3 requests, latest Jul 27, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetRemoved by FDA
- Not classified yetClassification not posted yetPosted 483 · 4 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit failures on CAPA and monitoring
OBSERVATION 1 The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, 1A. Your Quality Unit failed to: a. Ensure the timely implementation of corrective and preventive actions for the observed dried and cracked (b)(4) settle plates used for environmental monitoring and then incubated in (b)(4) incubator. Please refer to OBSERVATION 1B. b. Conduct adequate root-cause analyses for the ongoing Environmental Monitoring (EM) and Personnel Monitoring (PM) excursions. The Quality unit also failed to perform effectiveness checks on the implemented corrective and preventive actions, as evident by persistent fungal and bacterial recoveries despite implementing corrective actions in the clean room areas. Please refer to OBSERVATION 2 and OBSERVATION 3. c. Investigate the root cause of visual inspection failure during initial 100% inspection before proceeding to secondary/tertiary inspection of the filled syringes. Please refer to OBSERVATION 4. d. Evaluate air flow patterns under dynamic conditions in all ISO 5 classified BSC cabinets in the clean room. Please refer to OBSERVATION 3. 1B. Your firm's quality unit failed to ensure the timely implementation of corrective and preventive actions for dried and cracked (b)(4) media settle plates. The firm uses these (b)(4) plates for environmental monitoring in clean room areas as settle plates. After the plates are exposed for (b)(4) the plates are collected and incubated at (b)(4) incubator [illegible]. Upon removal from the (b)(4) incubator some of these plates are found to be desiccated and cracked. Your firm identified this issue and initiated a Product Quality Event - PQE-25-0085 on September 10, 2025. Several cracked plates were sent to a contract laboratory for growth promotion testing. The growth promotion testing passed and the PQE-25-0085 was closed on October 9, 2025. The PQE-25-0085 summary report prepared by [illegible] shows the drying and cracking of the media plates is due to low humidity levels within the (b)(4) incubator. Your humidity monitoring equipment installed in the incubator confirmed that humidity levels consistently fell below the recommended level. The incubator averaged 57%, dipping as low as 26.6% on days when the incubator door was opened frequently. It took multiple days for humidity to return to the average level of approximately 57%. It must be noted that the growth promotion test does not make the Incubator # (b)(4) fit for use. Growth promotion test uses a low inoculum of (b)(4), which is a controlled, ideal-condition challenge. This does not replicate the real-world conditions of passive air sampling (settle plates), where organisms may be stressed, desiccated, or present in very low numbers. I observed three (3) cracked plates which were incubated on April 16, 2026, and read in front of me on April 24, 2026. Two plates were used for environmental monitoring in (b)(4), and one plate was used in (b)(4) during compounding operations. Your firm identified this issue and to this date, effective corrective actions have not been implemented. Your acknowledgment of the problem for over nine months, combined with a lack of executed corrective actions, shows the quality system is not functioning effectively to address the identified deficiencies in a timely manner.
- Observation 2
Environmental monitoring and smoke study failures
OBSERVATION 2 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. Specifically, 2A. Your firm's environmental monitoring program failed to prevent or adequately address repeated fungal and bacterial contamination in ISO Class 7 and ISO Class 8 classified areas within the same cleanroom (b)(4) that support aseptic compounding operations conducted in ISO Class 5 Primary Engineering Controls. The environmental monitoring data collected between July 2025 and April 2026 document at least nineteen (19) separate fungal excursion events across ISO 8 rooms (Rooms [illegible] ISO 8) representing a recurring and unresolved pattern of mold contamination in the classified clean room environment supporting aseptic compounding operations. The following is the list of nineteen (19) documented fungal contamination events in the clean room area: Investigation# Date Opened Date Closed Room / ISO Class CFU Count Organism(s) Identified EME-25-0046 2025-07-22 2025-09-09 Room [illegible] ISO 8 1 CFU Periconia wasp. EME-25-0055 2025-07-31 2025-09-11 Room [illegible] ISO 8 1 CFU (3 total) Cladosporium cladosporioides EME-25-0056 2025-07-31 2025-09-11 Room [illegible] ISO 8 1 CFU Parengyodontium album EME-25-0057 2025-07-31 2025-09-19 Room [illegible] ISO 8 1 CFU Penicillium parvum EME-25-0087 2025-09-12 2025-10-17 Room [illegible] ISO 8 1 CFU (2 total) Cladosporium spp. (multiple species) EME-25-0088 2025-09-15 2025-10-22 Room [illegible] ISO 8 1 CFU (2 total) Pseudopithomyces palmicola EME-25-0089 2025-09-16 2025-10-17 Room [illegible] ISO 8 1 CFU (3 total) Parengyodontium album EME-25-0096 2025-09-26 2025-10-24 Room [illegible] ISO 8 1 CFU Trichiaromyces wortmannii EME-25-0097 2025-09-29 2025-12-11 Room [illegible] ISO ? 2 CFU Curvularia geniculata/senegalensis EME-25-0107 2025-10-15 2025-11-05 Room [illegible] ISO 8 2 CFU (6 total) Engyodontium rectidentatum EME-25-0114 2025-10-21 2025-12-11 Room [illegible] ISO ? 2 CFU Cladosporium spp. (multiple species) EME-25-0130 2025-11-04 2025-12-11 Room [illegible] ISO 8 1 CFU Crosphaeropsis arundinis / Penicillium decaturense (+ bacterial co-recoveries) EME-25-0156 2025-12-03 2026-01-30 Room [illegible] ISO 8 1 mold CFU (19 total) EME-25-0179 2025-12-29 2026-02-06 Room [illegible] ISO 8 1 CFU Mold - unidentified / Cladosporium spp.; Stachybotrys chlorohalonata EME-26-0036 2026-02-02 2026-03-18 Room [illegible] ISO 8 2 mold CFU (5 total) [illegible] EME-26-0037 2026-02-02 2026-03-13 Room [illegible] ISO ? 1 CFU Cladosporium halotolerans EME-26-0058 2026-02-18 2026-03-18 Room [illegible] ISO 8 1 mold CFU (12 total) Epicoccum nigrum (+ bacterial co-recoveries) EME-26-0119 2026-03-30 Still Open Room [illegible] ISO ? 1 CFU Alternaria alternata EME-26-0128 2026-04-02 Still Open Room [illegible] ISO 8 1 CFU (3 total) Beauveria bassiana Over sixteen (16) distinct fungal species were recovered across the monitoring period spanning July 2025 through April 2026. The isolates included environmental molds (Cladosporium, Penicillium, Alternaria, Curvularia), opportunistic pathogens (Beauveria bassiana, Parengyodontium album), mold Stachybotrys chlorohalonata which may be toxigenic. Despite implementation of corrective actions - including revisions to SOP-038 (Gowning and Handwashing Procedures), personnel retraining, and modification of the material sanitization process to incorporate a sporicidal agent - fungal contamination events have continued to recur through April 2026. It demonstrates an unresolved contamination trend despite repeated corrective actions. For investigation EME-25-0156, the firm documented no corrective action for a 19 CFU recovery event that included mold (Penicillium decaturense), citing ISO 8 gowning requirements as justification, without adequate assessment of risk to product quality. As of current inspection, at least five (5)
Shortened here; the PDF has the full text.
Show observations 3 to 4
- Observation 3
Personnel monitoring gowning failures
OBSERVATION 3 Production personnel were not practicing good sanitation and health habits. Specifically, Your firm failed to establish and maintain adequate controls to prevent repeated objectionable microorganism recoveries during personnel monitoring (PM) activities in ISO Class 5 and ISO Class 7 classified areas. Environmental monitoring records document six (6) personnel monitoring excursion events involving bacterial contamination from personnel gowning samples (chest, forehead, forearm) and fingertip samples collected between April 2025 and February 2026. Multiple excursions involved objectionable gram-negative organisms. The assigned root causes were generally insufficient aseptic gowning technique, improper material transfer, cleaning or personnel movement. The following is the list of six (6) documented contamination events: Investigation# / Date of Sample / Operator / Room / Sample Type / ISO Class / CFU Count / Organism(s) Identified / Lot Impacted / Root Cause / Sample Rejected EM-25-001 16 Apr 2025 Operator [illegible] Room [illegible] (b)(4) Chest 15 CFU Corynebacterium segementosum / Actinomyces oris/naeslundii K14/6202[illegible] Ineffective aseptic gowning technique during gowning and personnel movement NCR-25-013 EM-25-002 21 Apr 2025 Operator [illegible] Room [illegible] (b)(4) Chest 5 CFU Staphylococcus capitis K6421202[illegible] Insufficient aseptic gowning technique NCR-25-014 EM-25-003 06 May 2025 Operator [illegible] Room [illegible] (b)(4) chest & forehead 7 CFU Staphylococcus cohnii / Corynebacterium reicheleri / Reicelerivorans K1506[illegible] Ineffective aseptic technique during gowning and personnel movement EM-25-004 08 May 2025 Operator [illegible] Room [illegible] (b)(4) Chest 3 CFU Staphylococcus hominis K50[illegible] Insufficient aseptic gowning, QA stopped contact time not achieved (Repeat operator) EME-25-0017 28 May 2025 Operator [illegible] Room [illegible] (b)(4) Chest 2 CFU Proteus mirabilis / vulgaris / hauseri K1528[illegible] Insufficient material transfer execution; insufficient aseptic gowning technique EME-25-0155 20 Nov 2025 Operator [illegible] Room [illegible] (b)(4) Forearm 5 CFU Micrococcus luteus / Moraxella osloensis / Brevundimonas sp. (Media Fill) [illegible] Gowning practices and/or personnel movement Multiple operators were involved in repeated excursion events following the same root causes, and several operators appeared in more than one investigation. Despite corrective actions including personnel retraining and SOP revisions, bacterial contamination during personnel monitoring continued to recur throughout the observation period. The excursions occurred in ISO Class 5 and ISO Class 7 environments - indicating the implemented corrective actions were ineffective. Furthermore, the recovery of objectionable gram-negative organisms (Proteus mirabilis/vulgaris/hauseri, Moraxella osloensis) from personnel gowning samples represents a heightened risk to product sterility, as these organisms are not part of normal skin flora and indicate a failure in environmental and personnel hygiene control.
- Observation 4
Failed visual inspection investigations
OBSERVATION 4 There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, Your firm failed to conduct, or document, an investigation into the root cause of visual inspection failures prior to proceeding with secondary and/or tertiary inspections. A review of ophthalmic lot visual inspection records spanning from March 2025 through early 2026 identified forty-four (44) lots in which the firm proceeded directly to secondary inspection following a primary visual inspection failure which was characterized by major reject rates exceeding the [illegible] acceptance limit and/or major defects found at the primary AQL stage. There was no documented investigation and root cause analysis into the source and cause of these recurring defect types prior to reinspection. In addition, 2 lots (09262025 [illegible] and 0101-01-26-0067) proceeded to tertiary inspection after secondary inspection also failed, without a documented investigation of initial 100% visual inspection failure. The predominant defect types identified were intrinsic particulate and product fill volume defects. The table below shows details of all the 44 lots: Inspection Stage / Lot Number / Failure Reason / Key Defects / Proceeded To / Investigation Documented? 03032025 Primary VI Major reject 123 Product Fill Volume, 2 Intrinsic Particle Secondary No 03052025 Primary VI Major reject 129 Product Fill Volume, 3 Intrinsic Particle Secondary No 06112021 Primary VI Major reject 137 Intrinsic Particle, 9 Product Fill Volume Secondary No 06202020 Primary VI Major reject 10 Product Fill Volume, 38 Intrinsic Particle Secondary No 06252025 Primary VI Major reject 137 Intrinsic Particle, 6 Product Fill Volume Secondary No 01152025 Primary AQL 5 Major defects at AQL 5 Intrinsic Particle Secondary No 07242025 Primary VI Major reject 7 Intrinsic Particle, 11 Product Fill Volume Secondary No 05252025 Primary VI Major reject 141 Intrinsic Particle Secondary No 09042021 Primary VI Major reject 149 Intrinsic Particle, 15 Product Fill Volume Secondary No 09102025 Primary VI Major reject 10 Product Fill Volume, 38 Intrinsic Particle Secondary No 09182021 Primary AQL 3 Major defects at AQL 13 Intrinsic Particle Secondary No 09192025 Primary AQL 8 Major defects at AQL [illegible] Intrinsic Particle Secondary No 09232025 Primary AQL 3 Major defects at AQL 1 Product Fill Volume, 2 Intrinsic Particle Secondary No 09242025 Primary AQL 3 Major defects at AQL 13 Intrinsic Particle Secondary No 09252025 Primary AQL 12 Major defects at AQL 12 Intrinsic Particle Secondary No 09252020 Primary VI Major reject 127 Intrinsic Particle, 11 Product Fill Volume Secondary No 09262025 Primary VI Major rejects [illegible] Intrinsic Particle Secondary No (NCR-25-0104) 09262025 Primary AQL 6 Major defects at AQL [illegible] Intrinsic Particle Secondary No 09292025 Primary AQL 12 Major defects at AQL 12 Intrinsic Particle Secondary No 10022020 Primary VI Major rejects 14 Product Fill Volume, 42 Intrinsic Particle Secondary No 10072025 Primary VI Major rejects 13 Product Fill Volume, 29 Intrinsic Particle Secondary No 10092025 Primary VI Major rejects 13 Product Fill Volume, 40 Intrinsic Particle Secondary No 10102025 Primary VI Major rejects 134 Intrinsic Particle, 4 Product Fill Volume Secondary No 10102025 Primary VI Major rejects 12 Product Fill Volume, 33 Intrinsic Particle Secondary No 10152025 Primary VI Major rejects 19 Product Fill Volume, 33 Intrinsic Particle Secondary No 10202025 Primary VI Major rejects 12 Product Fill Volume, 30 Intrinsic Particle Secondary No 10212025 Primary VI Major rejects 120 Product Fill Volume, 16 Intrinsic Particle Secondary No 10222025 Primary VI Major rejects 13 Product Fill Volume, 16 I
Shortened here; the PDF has the full text.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Training , Education , Experience overall
Employees engaged in the manufacture and processing of a drug product lack the training and experience required to perform their assigned functions.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release.
Show 3 more citations
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Jul 27, 2026. Each one asked for a Form 483.
Inspection ending May 7, 2026Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 27, 2026FDA-FOIA-2026-7177Form 483· 1 of 5 sitesRecords released
Inspection ending Jan 24, 2025OAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 19, 2025FDA-FOIA-2025-8856Form 483· 1 of 3 sitesRecords released
- Jun 16, 2025FDA-FOIA-2025-7675Form 483· 1 of 10 sitesWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.194Laboratory records1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3027507354 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3027507354. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.