Eagle Pharma Outsourcing LLC
2200 Riverchase Ctr Ste 675, Hoover, Alabama, United States
FEI 3011688532
FDA has 4 inspections on file for Eagle Pharma Outsourcing LLC in Hoover, Alabama (FEI 3011688532), from 2015 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 5 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the three FOIA requests for this site has asked FDA for this inspection's records.
The most recent OAI inspection ended on May 18, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.113(b).
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2015–2025
- 2 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- 2 posted 483s not matched to an inspection
- Requested under FOIA
- 3 requests, latest Aug 18, 2025
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Show 1 more citation
Deviations from laboratory control requirements
Deviations from written specifications, sampling plans and test procedures are not recorded.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Incomplete laboratory controls for preservatives
Laboratory controls do not include the specifications and test procedures designed standards of identity, strength, quality, and purity. Specifically, finished product release testing does include preservative content for injectable drug products. All drug products are sold and include preservatives, such as 5 4 ti) (4)
- Observation 2
Inadequate sterile-processing procedures
Appropriate procedures designed to prevent microbiological contamination to be sterile are not established and followed. There process. Specifically, a) Pharmaceutical grade, 15 4 which has not been validated. i. 6 Lt (i.e. t5) using this (15)(4) include Brompheniramine Tromethamine, Sodium Bicarbonate, and Vitachrom. ii. specification from the manufacturer. There equivalent between the different 6JJ 4) Testosterone Cypionate is b) sterilized using these Medroxyprogesterone Acetate, and Triamcinolone Acetonide.
Show observations 3 to 4
- Observation 3
Deficient aseptic area monitoring systems
Aseptic processing areas are deficient regarding systems for the aseptic conditions. Specifically, there is [illegible] used to monitor pressure differentials, temperature, and relative [illegible] classified areas used for sterile compounding.
- Observation 4
Unqualified/uncalibrated weighing equipment
Equipment and utensils are not maintained at alter the safety, strength, quality, or purity of for the weighing of drug components, and (5) certified weight or routinely qualified for use. The lacking traceability and certification. The balance has not been qualified including precision/repeatability, off-center, and linearity testing.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to review failing batch potency
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, two injectable drug products were released and distributed after the receipt of failing potency testing. a) Lipo B, Lot 07072015LIPO, was compounded on 7/17/2015. Out of the [illegible] 10 mL vials produced, [illegible] were sent for testing. Potency results were reported on 7/23/2015 and documented one of the active ingredients, methylcobalamin, was not detected in the product. An undated investigation determined the methylcobalamin degraded. The product insert was changed to remove methylcobalamin from the active ingredients with a note stating the product contains traces of methylcobalamin. This product was released on 7/23/2015 and first distributed on 7/27/2015. As of 8/14/2015, [illegible] vials have been distributed. b) Vitachrom, Lot 07012015YC, was compounded on 7/1/2015. Out of the [illegible] 10 mL vials produced, [illegible] were sent for testing. Potency results were reported on 7/28/2015 and documented one of the active ingredients, Riboflavin-5-Phosphate Sodium, USP, was found to be at approximately 80% of the expected potency. An undated investigation determined a process error should be added to the amount of Riboflavin in the formulation of Vitachrom. The product insert was changed to adjust the amount of Riboflavin present in the product based on the test result. This product was released on 7/28/2015 and first distributed on 7/23/2015. As of 8/14/2015, [illegible] vials have been distributed.
- Observation 2
Inadequate aseptic contamination procedures
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Specifically, a) Injectable drug suspensions are sterilized in a [(b)(4)] [(b)(4)] in the ISO 7 Lab prior to being aseptically filled into vials in the ISO 5 compounding room. The validation for this process, approved 6/2/2015, supports [(b)(4)]. On 7/15/15, the [(b)(4)] was [(b)(4)] of methylprednisolone [(b)(4)]. The validation data does not support the process for this. b) On 8/4/2015, bulk Ketorolac Tromethamine, Lot 08042015KT, was left in an uncovered 5 L beaker during [(b)(4)] the ISO 5 compounding room, transfer onto the ISO 5 work surface, and during [(b)(4)] into a sterile IV bag. c) On 8/4/2015, during observation of compounding for Ketorolac Tromethamine, Lot 08042015KT: - The operator was observed to fill [(b)(4)] product into vials while arm was moving over empty, sterile, depyrogenated vials. - The operator was observed to drop hands below the table (air flow), rest hands on the critical work surface, and handle objects outside of the immediate work area without re-sanitizing hands prior to entry back into the critical ISO 5 work area. - Materials were transferred onto the critical work surface from the storage shelf without being sanitized. d) Smoke studies are not performed under dynamic conditions. e) The [(b)(4)] used for [(b)(4)] has no documentation of calibration.
Show observations 3 to 10
- Observation 3
Deficient aseptic equipment maintenance
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, airflow over the ISO 5 work surface is not laminar. The [(b)(4)] ISO 5 "hood" is composed of HEPA [(b)(4)] and stainless steel tables acting as the work surface. The tables do not fit the length of the wall exactly and leave a gap of approximately 8 inches at one end. During review of the smoke study performed on 5/8/2015, I observed smoke moving back towards the HEPA filters along the adjoining line between tables. Smoke was also observed to accumulate and sit in the gap between the table and wall.
- Observation 4
Inadequate protective apparel/gowning
Protective apparel is not worn as necessary to protect drug products from contamination. Specifically, compounding for Ketorolac Tromethamine, Lot 08042015KT, was observed on 8/4/2015 and the following conditions were noted: a) An operator was observed to wear the same sterile mask between the ISO 7 Lab and ISO 5 Compounding room. The operator moved between rooms with the same mask as follows: ISO 8 (Ante Room), to ISO 7 (Lab), to ISO 8 (Ante Room), to ISO 7 (Vestibule Room), to ISO 5 (Compounding Room). Procedure states a new sterile mask be donned [(b)(4)]. b) Personnel enter the ISO 5 compounding room from the ISO 7 vestibule room without wearing gloves. Sterile gloves are donned after entry in the ISO 5 room. c) Operators' cheeks and necks were observed to be exposed during operations in the ISO 5 compounding room. d) Gowning for aseptic operations does not include the use of sterilized goggles.
- Observation 5
Insufficient cleaning/disinfection procedures
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a) Non-sterile, non-shedding wipes are used in the ISO 5 clean room. b) On 8/4/2015, I noted approximately 8 inches of the edge of each stainless steel table was not cleaned and sanitized during room set-up. These tables comprise the ISO 5 work surface.
- Observation 6
Environmental monitoring lacks neutralizers
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, [(b)(4)] plates, used for personnel and environmental monitoring, do not contain disinfectant neutralizers, resulting in potentially false negative results.
- Observation 7
No stability data for expiration
An adequate number of batches of each drug product are not tested to determine an appropriate expiration date. Specifically, there is no stability data to support the 180 expiration date assigned to all injectable drug products.
- Observation 8
Unvalidated laboratory test methods
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, injectable drug products are not tested for specifications using validated methods.
- Observation 9
Missing required labeling information
The labels of some of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) and (B). Specifically, the following information is not found on some of your drug product labels: • The address and phone number of the outsourcing facility. Examples of drug product labels that do not contain this information include: o Vitachrom Injection, 10 mL o Triamcinolone Acetonide 50 mg/mL, 10 mL sterile injection o Methylprednisolone Acetate 80 mg/mL, 10 mL sterile injection o Lipo B sterile injection, 10 mL o Ketorolac Tromethamine 30 mg/1 mL, 300 mg/10 mL o Dexamethasone Acetate LA 8 mg/mL, 10 mL sterile injection o Tri-Mix 30/2/40 injection, 5 mL o Tri-Mix 30/2/20 injection, 5 mL o Tri-Mix 30/1/10 injection, 5 mL o Bi-Mix 30/1 injection, 5 mL • The strength (of each active ingredient). Examples of drug product labels that do not contain this information include: o Vitachrom Injection, 10 mL • The statements 'This is a compounded drug' and 'Not for resale.' Examples of drug product labels that do not contain this information include: o Flurbicaine o Keprocaine o Neurocaine
- Observation 10
Failed to report compounded products
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the six months prior to registration as required by section 503B(b)(2)(A). Specifically, the following products were compounded and not identified on your submitted list on June 24, 2015: o Arthro-Infusion o Flurbicaine o Flurbi-Flex o Testosterone o Keta/Baclo/Gaba/Imp/Nifedipetra o Libido Cream o LibidoMax Cream o Keprocaine o Myo-Infusion o Kepro-Flex o Neurocaine o Plantar Flex o Shingleve o Woundheal o Progesterone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Aug 18, 2025.
Inspection ending Feb 27, 2025VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Aug 18, 2025FDA-FOIA-2025-9950EIRWithdrawn
Inspection ending Aug 12, 2021VAI
2 requests. In the inspection history above. FDA has posted its Form 483.
- Jun 19, 2025FDA-FOIA-2025-7846Form 483Records released
- Feb 13, 2024FDA-FOIA-2024-1546EIRClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.28Personnel responsibilities1 of 2
- 21 CFR 211.42Design and construction features1 of 2
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3011688532 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3011688532. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.