Skip to content

JKR Pharmacy Ventures, LLC

Kentucky

FEI 3033262505

FDA has one inspection on file for JKR Pharmacy Ventures, LLC in Kentucky (FEI 3033262505). It ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 11 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
1, in 2025
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 11 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate aseptic environmental monitoring

      OBSERVATION 1 Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, A. Your firm is not performing environmental or personnel monitoring in the classified areas (ISO [redacted]) each day that sterile drug products are produced. Viable surface sampling, viable active air sampling, and nonviable air sampling are performed only when the hoods are re-certified. In addition, your firm does not perform nonviable particulate monitoring in the ISO [classified] workstations during the production of sterile drug products. The action limit specifications (ISO Class [redacted] colony forming units per contact plate (cfu/cm2)) used for microbiological evaluation of airborne and surface bacteria are not adequate for ISO [classified] areas, and there is no assurance that the ISO [classified] areas are tested under dynamic conditions. B. Your firm is not monitoring each technician working in the ISO [classified] Laminar Air Flow Workstations (LAFW) or Biological Safety Cabinet (BSC) Hoods each day during production. The firm is currently sampling the fingertips of technicians only when a media fill is performed. [(b) (4)] Your pharmacy technicians produced fingerstick fingertip sampling only during media fills and did not perform fingertip sampling prior to leaving the ISO area. C. Your firm is not performing viable active air or nonviable air sampling during media fill. D. Your firm does not perform gowning qualification, including qualification for technicians producing sterile drug products.

    2. Observation 2

      Aseptic/sterilization validation missing

      OBSERVATION 2 Procedures designed to prevent microbiological contamination did not include validation of the aseptic and sterilization process. Specifically, A. Media fills or aseptic process simulations performed do not simulate actual production conditions or cover worst case conditions. Your firm does not simulate every container type during media fills. During routine production your technicians and pharmacists fill media into a total of various container types (vials, di-optainers, syringes, and bags). Currently, your firm fills various size vials [(b) (4)] and uses control vials. However, during routine production your firm fills both [(b) (4)] vials and [(t5) (4)] vials, di-optainer bottles, syringes, and bags. Documentation of the media fills performed are incomplete and do not include how the media was prepared, the order in which the vials are filled with media, and the volume filled in each. Documentation does not include all consumables used such as stoppers, beakers, foil, and bags in the ISO hoods. B. Your firm does not perform growth promotion testing on media used during media fills. For example, a media fill was performed on 10/15/2025 using media with expiration [(l5) (4)], but growth promotion testing was not performed on the media lot prior to use. C. Smoke studies are not performed in any of the ISO hoods to show that air quality is appropriate to maintain aseptic conditions during the production of sterile drug products. For example, on [(l5) (4)] workstations used in production of Isoflupredone Acetate Injection Suspension 2 mg/mL (Lot 121025C.29, BUD 01/24/2026) airflow smoke study pattern tests conducted in October 2025 do not certify that the airflow meets acceptance criteria under these or similar conditions during the production of sterile drug products. D. Your [(D) (4)] equipment used to sterilize components and sterile drug products produced onsite has not been validated. The effectiveness of the [(6) (4)] sterilization cycle has not been initially validated or periodically verified. Since 09/03/2025, your firm has dispensed sterile drug product lots that are sterilized via [(6) (4)]. E. Your [(b) (4)] onsite sterilization minutes used to render drug product sterile has not been initially qualified or periodically verified. Since 09/03/2025, your firm has dispensed sterile drug product lots that contain ingredients sterilized via [(6) (4)], including Diclofenac Ophthalmic Ointment 0.1% (Lot 121025D.06, BUD 01/24/2026) and Estradiol Cypionate (ECP) Injection 10 mg/mL (Lot 121025B.37, BUD 01/24/2026).

    Show observations 3 to 11
    1. Observation 3

      Missing written contamination procedures

      OBSERVATION 3 Procedures designed to prevent microbiological contamination are not established, written and followed. Specifically, A. Your firm has no written procedure for how to separate multiple batch preparations to prevent cross contamination or follow-ups during the preparation of ingredients. Several preparations were performed in the non-hazardous sterile preparation room, including Estradiol Cypionate (ECP) Injection 10 mg/mL (Lot 121025B.37, BUD 01/24/2026), Acetylcysteine Injection Solution (PF) 200 mg/mL (Lot 121025F.57, BUD 01/24/2026), Isoflupredone Acetate Injection Suspension 2 mg/mL (Lot 121025C.29, BUD 01/24/2026), and Diclofenac Ophthalmic Ointment 0.1% (Lot 121025D.06, BUD 01/24/2026). B. Your firm has no written procedure for how to perform cleaning after the [(6) (4)] is used to sterilize. The firm does not have documented procedures for [(6) (4)] testing using a [(D) (4)]. Examples include Acetylcysteine Injection Solution (PF) 200 mg/mL (Lot 121025F.57, BUD 01/24/2026), L-Arginine Injection 100 mg/mL (Lot 102025M.57, BUD [illegible]), and Guanabenz Acetate Injection 20 mg/mL (Lot 120925I.32, BUD 01/23/2026).

    2. Observation 4

      Inappropriate personnel gowning

      OBSERVATION 4 Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform. Specifically, Your firm's pharmacy technicians operating in the ISO classified areas don scrubbs worn from home, a disposable non-sterile gown, a single non-sterile hair net, no eye protection, no face mask, and non-sterile shoe covers. Your firm's general gowning requirements allow exposed skin on the face of personnel including, but not limited to, their eyes, forehead and neck while preparing sterile drug products in the ISO classified areas. In addition, when exiting the hazardous sterile preparation room (ISO [classified]), the technicians and pharmacists completely de-gown of gown, gloves, shoe covers, face mask, and hair net and then enter the common preparation room (ISO [classified]) compounding area.

    3. Observation 5

      Insufficient component procedures

      OBSERVATION 5 Written procedures are lacking which describe in sufficient detail the receipt, identification, sampling, testing and approval of components. Specifically, A. Your firm does not perform microbiological testing for purchased components used to prepare non-sterile drug products. Your firm fails to ensure that the purchased [(6)-(4)] Water, USP, pharmaceutical use, meets specifications. Non-sterile drug products produced using [(b) (4)] water include EPM Oral Suspension (Sulfadiazine and Pyrimethamine) 333 mg/mL and 16.67 mg/mL, Penicillin/Gelatin Gutteral Pouch Infusion 250,000 units/mL, Chloramphenicol Ophthalmic Ointment 1%, and Tris EDTA Solution. B. Your firm uses a store-brand liquid detergent to clean hand wash glassware, utensils and other supplies used to compound sterile and non-sterile drug products. Your firm failed to justify the use of a non-pharmaceutical-grade cleaning agent for product-contact equipment and failed to demonstrate that such practices do not adversely affect drug quality. C. Your firm uses [(b) (4)] but does not have written procedures that specify the process and criteria for determining and documenting the appropriate hold times or Beyond Use Dates (BUDs) for these formulas, including Fixed Oil Base, No Flavor Lot [(6)-(4)] and Pergolide Suspension (Apple) 200 mg/5 mL.

    4. Observation 6

      Containers/closures not sterilized

      OBSERVATION 6 The final and intermediate containers/closures used for sterile drug products are not always sterilized or depyrogenated. Specifically, A. Non-sterile vials and stoppers are purchased and then sterilized onsite. The cleaning and sterilization processes for the stoppers and vials have not been validated. Both stoppers and vials are used as the final container for sterile compound preparations. On 12/10/2025, sterile stoppers and vials were observed being stored in the common preparation room and then staged for use for the production of sterile drug products. In addition, opened but unused rubber stoppers or stoppers not used within [(b) (4)] days are allowed to be placed back into inventory. The firm has not validated the re-sterilization process and has no procedure or process for tracking sterilization cycles for [(t5) (4)] stoppers. B. Reusable glassware, such as but not limited to beakers used for compounding drug products are not always sterilized or depyrogenated. Non-sterile glassware stored on a shelf in the ISO classified compounding preparations was observed.

    5. Observation 7

      Gloved contact without changing gloves

      OBSERVATION 7 Personnel were observed touching equipment or other surfaces located outside of the ISO area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. Specifically, on [(6)-(4)], during the production of Diclofenac Ophthalmic Ointment 0.1% (Lot 121025D.06, BUD 01/24/2026), your firm's sterile compounding technician picked up a balance foot that fell on the floor while wearing sterile gloves, wiped the balance, sprayed the gloves, and then returned to aseptically filling the drug product without changing gloves. The drug product (Lot 121025D.06, BUD 01/24/2026) was dispensed as office stock on 12/10/2025.

    6. Observation 8

      Inadequate product testing/release

      OBSERVATION 8 Testing and release of drug product for distribution do not include appropriate laboratory testing to ensure satisfactory conformance to the identity and strength of each active ingredient. Specifically, A. Your firm does not conduct routine testing for potency (assay) for all drug products produced by your firm, including both sterile and non-sterile products. B. Your firm does not conduct routine testing of all of your sterile products for sterility and/or endotoxin prior to release and distribution.

    7. Observation 9

      Supplier COAs accepted without validation

      OBSERVATION 9 Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation. Specifically, your firm produces sterile and non-sterile drug products using bulk drug substances, excipients, and other materials but does not perform incoming testing of incoming bulk drug substances or excipients used to produce these drug products. Currently your firm accepts glycerin as an excipient or ingredient for various formulations without documenting that the ingredient is tested for Diethylene Glycol (DEG) and Ethylene Glycol (EG) contamination. For example, Omeprazole & Cimetidine Oral Suspension 114 mg/mL & 50 mg/mL (Lot 093025AC.17, BUD 12/29/2025) was produced using Glycerin 99% USP (Lot [illegible]) and the firm received the certificate of analysis (COA) for glycerin but did not review and document that the supplier tested the lot for DEG/EG and the test results were provided.

    8. Observation 10

      No stability testing or CCI program

      OBSERVATION 10 There is no written testing program designed to assess the stability characteristics of your finished drug products. Specifically, Your firm does not have a written stability testing program to determine Beyond Use Dates (BUD) placed on all your drug products. Your firm has no written and approved stability protocols and written and approved reports. In addition, your firm has not performed container closure integrity testing. For example, the drug product Detomidine HCl & Xylazine Injection 20 mg/mL & [illegible] (Lot 112525H.50, BUD 01/09/2026) has an assigned BUD of 45 days. Your firm lacks an approved protocol or a scientific rationale to support the assigned BUD.

    9. Observation 11

      Quality unit procedures not established

      OBSERVATION 11 The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. A. Your firm has no written procedures for the responsibilities of the quality unit, including release or rejection of the finished animal drug products. B. Your firm lacks written procedures for the management and handling of investigation of unexplained discrepancies whether or not the compounded lot has been distributed. The quality unit did not adequately investigate environmental monitoring excursions following room recertifications in October 2025. Unacceptable microorganism concentrations were reported for air samples collected from four locations in the common preparation area. Total colony forming units (cfu) action levels were exceeded: locations reported (9 cfu), (13 cfu), and (20 cfu), and the colonies were identified as Bacillus, Micrococcus, Staphylococcus, non-sporulating fungi, yeasts, and gram-negative rods. No root cause or corrective actions and preventative actions for the excursions were documented. The locations were resampled in December 2025 and unacceptable microorganism concentrations were reported. Air samples collected from location [(q)] (14 cfu) in the sterile area identified gram-negative rods, Micrococcus, Staphylococcus, and yeasts. C. Your firm lacks written procedures for the management and handling of complaints, change controls, and adverse events. D. Written procedures are not reviewed and approved with a written or electronic official signature. E. Your firm's quality unit does not ensure that batch records do not contain incomplete documentation for drug products, including the actual production start and end times, technician and pharmacist signatures, lot number of the packaging materials such as vials, stoppers, syringes, and bottles used to package finished products, equipment configurations, and identification for equipment such as hoods used for testing. DATES OF INSPECTION 12/03/2025 (Wed), 12/04/2025 (Thu), 12/05/2025 (Fri), 12/10/2025 (Wed), 12/11/2025 (Thu), 12/15/2025 (Mon), 12/16/2025 (Tue), 12/17/2025 (Wed), 12/18/2025 (Thu), 12/19/2025 (Fri)

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3033262505 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3033262505. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.